Heat & Glo LifeStyle 2197-980 owner manual Log Placement Instructions Log Assembly LOGS-SOHOCE

Page 59

E. Log Placement Instructions

Log Assembly: LOGS-SOHOCE

 

 

2

3

1

LOCATING TABS

Figure 14.1

Figure 14.2

CAUTION: Logs are fragile. Carefully remove the logs from the packaging.

1

Figure 14.3

2

Figure 14.4

1

Step 1. Place Log #1 (SRV2111-700)against rear right tab with its slot over center locating tab.

2 1 3

Figure 14.5

Step 3. Place Log #3 (SRV2111-702)so the top rests on Log #1 against Log #2. The base slot on Log #3 will fit over the locating tab on the front right hand side.

Step 2. Place Log #2 (SRV2111-701) onto base pan such that Log #2 fits in groove of Log #1. Push it back against the left hand side locating tab. Ensure burner ports are not covered by logs.

Heat & Glo • SOHO-N-AUB2197-980 Rev. F • 5/12

59

Image 59
Contents Do Discardnot Ref No GSCS20167 AS45532008SAI Global What to do if you smell gasHeat & Glo SOHO-N-AUB 2197-980 Rev. F 5/12 Homeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingLimited Lifetime Warranty Australian Warranty InformationOther Rights Warranty Conditions and ExclusionsWarranty Exclusions Perth This warranty is void ifHOW to Claim Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Decorative Doors and Fronts Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceFinal inspection by Lighting Instructions IPIControl Module Control Module OperationAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation Ember PlacementTypical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesClearances to Combustibles Constructing the Appliance ChaseClearances Combustible Mantels Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsClearance MIN. Clearance in. mmVent Information and Diagrams V1 Minimum H1 + H2 Maximum Top Vent Horizontal Termination One ElbowTwo Elbows V1 Minimum H1 MaximumV1 Minimum H1 Maximum V2 Minimum H2 Maximum Top Vent Horizontal Termination Three ElbowsUSE SLP Series Components only MAX. RUN Top Vent Vertical TerminationStraight Up Vertical Flue System V1 = 38 ft. Max .58 m V1 = 3 ft. Min mm Top Vent Vertical Termination No ElbowIdentifying Flue Components Flue System Approvals And InstallationsModel Flue Termination ApprovalsMinimum Maximum V1 = 38 ft .58 m MaximumTop Vent Vertical Termination Three Elbows Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe SLP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Securing and Leveling the Appliance Appliance PreparationInstall Trim and/or Surround Components Removal For ServiceParts Replacement Adjustments And Replacement PartsAssemble Vent Sections Installing Vent Pipe SLP PipeSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Support Brackets10 Flue Pipe & Firestop Install FirestopsFlue Termination For Horizontal Terminations using the SLP-TRAPHeat Shield Requirements for Horizontal Termination Install Metal Roof FlashingInstall Vertical Termination Cap Assemble and Install Storm CollarGas Pressure Requirements Gas Connection Gas InformationGAS Access Electrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Optional Accessories RequirementsBlower Control Module Operation Introduction Kit ContentsInstallation Precautions Fireplace Specific InformationInstallation of Remote Control Housing Changing Temperature ScaleRemote Position Learn Button AUX300CE Module InstallationFan Installation Programming the RC300AU to the Control ModuleFunction Buttons Idle When Remote is in on ModeStandby mode Display ScreenAdjusting Fan Speed About on ModeAbout OFF Mode Adjusting Flame HeightPower Outage Adjusting ThermostatAdjusting Timer Setting the Child LockSymptom Possible Cause Corrective Action Frequently Asked Questions/TroubleshootingMantel Projections Non-Combustible Materials SpecificationFinishing Framing and Finishing InstructionsAccessories Appliance SetupRemove Fixed Glass Assembly Clean the ApplianceLog Placement Instructions Log Assembly LOGS-SOHOCE Optional Reflective Liner Rock Tray Install Media Rock KitIntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action If the pilot continues Location Inches Millimeter Appliance Dimension DiagramGAS Line Electrical Access Reference MaterialsInspect Maintenance Tasks Maintenance TasksSLP-HVS SLP-FS Vent Components DiagramsSLP45 SLP90DRC-RADIUS SLK-SNKD SLP-CCS-BK SLP-TVHWSLP-DCF-BK SLP-WT-BK SL-2DVP 15-1/2 394 mm 203 mm Heat Shield 384 mm Max EffectiveLength Horizontal Termination CapBeginning Manufacturing Date March Service PartsTop Vent Gas Fireplace Part Description Comments Part NumberSOHO-N-AUB #13 Valve AssemblyRock Media Option Optional AccessoriesContact Information

2197-980 specifications

The Heat & Glo LifeStyle 2197-980 is a cutting-edge contemporary gas fireplace designed to seamlessly integrate into modern living spaces while providing warmth and aesthetic appeal. This model represents a perfect blend of innovative technology and stylish design, making it an excellent choice for homeowners seeking both functionality and elegance.

One of the standout features of the LifeStyle 2197-980 is its impressive heat output. With an efficiency rating that's designed to maximize warmth while minimizing energy consumption, this fireplace efficiently distributes heat throughout the room, providing a comfortable environment even during the coldest months. The unit is equipped with an advanced heating system that ensures rapid warmth without compromising on style.

Another notable characteristic is the customizable flame presentation. The LifeStyle 2197-980 offers a stunning array of flame colors and intensity settings, allowing users to create the perfect ambiance for any occasion. This fireplace utilizes the latest in LED technology to produce realistic flames that can be adjusted to fit the desired aesthetic, whether you prefer a soft glow for an intimate gathering or a robust flame for a cozy family night.

The design of the LifeStyle 2197-980 emphasizes versatility and ease of installation. It can be incorporated into various wall styles, making it an adaptable choice for different home layouts. The unit is designed for direct vent installation, which not only enhances safety but also ensures that indoor air quality remains pristine. The glass front and minimalist frame add a sophisticated touch, enhancing the overall décor of the space.

Safety is a paramount consideration in the LifeStyle 2197-980, equipped with features such as an automatic shut-off system that activates under certain conditions to prevent overheating. The fireplace also comes with a remote control, allowing users to adjust settings conveniently from anywhere in the room.

In summary, the Heat & Glo LifeStyle 2197-980 embodies modern fireplace technology with its efficient heating, customizable flames, versatile installation options, and safety features. It is an ideal choice for those who value design, comfort, and efficiency in a home heating solution, making it an investment that enhances any living space. Whether for cozy nights in or social gatherings, this fireplace stands out as a centerpiece that combines form and function beautifully.