Desa (V)KC42PE Continued, Installing Horizontal Vent Cap, Noncombustible Exterior, Screws

Page 11
Figure 10 - Installing Horizontal Vent Cap

Venting Installation

instructions

Continued

(Noncombustible Exterior) WARNING: Do not recess vent termination into any wall. This will cause a fire hazard.

6.Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1/2" round hole and attach to the exterior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal between it and the outside wall. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete or other types of sidings.

Combustible Exterior Wall: For vinyl siding, stucco or wood exteriors, a siding standoff may be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging the siding materials. Siding material must be cut to accommodate standoff. Bolt the vent cap to the standoff. Ap- ply non-hardening mastic around outside edge of standoff. Position the standoff/cap assembly in the center of the 10 3/4" square hole and attach to exterior wall with wood screws provided (see Figure 11). The siding standoff must sit flush against the exterior fascia material.

7.Combustible Exterior Wall Only: Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12).

8.Carefully move fireplace, with vent assembly attached, toward wall and insert vent pipe into horizontal termination. The pipe overlap should be a minimum of 11/4" (see Figure 13, page 12).

9.Combustible Exterior Wall Only: Slide wall firestop against interior wall surface and attach with screws provided. See Figure 13, page 12, for horizontal termination details.

10.Place fireplace into position and shim with noncombustible material if needed. Nail or screw side flanges to framing to secure unit in place. IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level it will not work properly.

Apply Mastic on

All Four Sides

Vent Cap

Wood Screw

Figure 10 - Installing Horizontal Vent Cap

(Noncombustible Exterior)

Cut Siding Away to

Fit Standoff

Standoff Wood

Screw

Vent

Cap

Apply Mastic

Screws

to All Four Sides

 

Figure 11 - Installing Siding Standoff

(Combustible Exterior Wall)

Interior Wall

Surface

Wall

Firestop

Vent Cap (Horizontal Termination)

ScrewScrewsHorizontal

Vent Pipe

Figure 12 - Connecting Vent Cap with

Horizontal Vent Pipe

116240-01E

www.desatech.com

11

Image 11
Contents WHAT TO DO IF YOU SMELL GAS poisoning may lead to death Table of ContentsSafety Information DANGER Carbon monoxideContinued Safety informationLocal Codes Safety informationProduct IdentificationLocation and space requirements Product FeaturesPre-Installation Preparation Figure 3 - Fireplace Bottom DimensionsClearances ContinuedContinued Pre-InstallationInstallation PreparationFigure 7 - Minimum Clearances for Termination Cap Location of Termination CapD E B L Venting Installation Instructions Figure 8 - Vent Pipe Connections Venting Installation instructionsINSTALLATION PLANNING ContinuedContinued Figure 10 - Installing Horizontal Vent CapFigure 11 - Installing Siding Standoff Figure 12 - Connecting Vent Cap withVertical GROUND FLOOR INSTALLATIONContinued Square Termination90 Elbow CORNER INSTALLATIONSNORKEL TERMINATION INSTALLATION Continuedwith Termination at 90 with Fireplace HORIZONTAL SYSTEM INSTALLATIONUSING TWO 90 ELBOWS ContinuedContinued installation for vertical terminationFlat Ceiling Installation Figure 20 - Installing FirestopFigure 21 - Vertical Venting Configuration Using Two 90 ElbowsConfiguration Using One 90 Elbow ContinuedVertical Venting Configuration Using Two 90 ElbowsConfiguration With No Horizontal Run ContinuedNumber Description parts list for venting kits and componentsContinued DESA 5/8 Pipe & Vent Kits Number DescriptionCHECK GAS TYPE Fireplace InstallationInstalling optional blower accessories Figure 28 - Blower Model BKT Model BKT InstallationContinued Installation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Pointing Down Propane/LP Only Installation Items NeededContinued Figure 30 - External Regulator with VentCHECKING GAS CONNECTIONS ContinuedRemoving Glass Door Pressure Testing Fireplace Gas ConnectionsRemoving Louver Panels Figure 36 - Removing Louver PanelInstalling lava rock and glowing embers Figure 41 - Installing Battery into Back of Installing Lava Rock and Glowing Embers, pageFigure 40 - Installing the WRC Remote Receiver Figure 39 - Installing Rear Brick Panel120V AC IGNITOR LEADPILOT 24V ACTO TURN OFF GAS TO APPLIANCE for your safety Read before lightingOperating Fireplace lighting instructionsFigure 44 - Correct Pilot Flame Pattern see Troubleshooting, pagesee Troubleshooting, page ContinuedCAUTION Do not vacuum if pieces are hot Cleaning and Maintenanceventing system Cleaning and MaintenanceTroubleshooting OBSERVED PROBLEMContinued TROUBLESHOOTINGWiring Diagram, page WARNING If you smell gas Shut off gas supply Specifications Replacement PartsService Hints Technical ServiceAccessories 116240-01E 24 22 23 4 1 9 11 3 14 167 8 PARTS LIST illustrated parts breakdown Burner Pan Assembly LIMITED WARRANTY DIRECT-VENTFIREPLACE Warranty InformationKEEP THIS WARRANTY