Desa (V)KC42PE installation manual Troubleshooting, Continued, Wiring Diagram, page

Page 32
TROUBLESHOOTING

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Pilot will not stay lit

1.

Loose wiring on ignitor wire

1.

Check wiring connection.

 

 

to ignition module and/or poor

 

Refer to wiring diagram (see

 

 

ground to ignition module

 

Wiring Diagram, page 27)

 

 

 

 

and/or check ground wire to

 

2.

Pilot flame too low to sense

2.

ignition module

 

Clean and adjust pilot burner

 

 

 

 

and check gas supply and inlet

 

 

 

 

pressure to unit

 

 

 

 

Note: Have a qualified techni-

 

 

 

 

cian replace pilot assembly if

 

 

 

 

broken or corroded

 

 

 

 

 

 

No gas to burner, although wall

1.

Wall switch wires defective

1.

Check electrical connections

switch and valve are set to the

 

or too long

 

 

 

ON position

 

 

 

 

 

Frequent pilot outage

1.

Pilot flame may be too low,

1.

Clean and adjust pilot flame for

 

 

causing safety pilot to “drop

 

maximum flame impingement

 

2.

out”

2.

on thermopile

 

Improper venting or excessive

Have the vent system inspect-

 

 

blockage

 

ed, including the termination

 

 

 

 

cap. Remove any restriction

 

 

 

 

or obstruction

 

 

 

 

 

 

Fireplace produces a clicking/tick-

1.

Metal expanding while heating

1.

This is normal with most

ing noise just after burner is lit

 

or contracting while cooling

 

fireplaces. If noise is exces-

or shut off

 

 

 

sive, contact qualified service

 

 

 

 

person

 

Slight smoke or odor during initial

1.

Residues from manufacturing

1.

Problem will stop after a few

operation

 

processes and logs curing

 

hours of operation

32

www.desatech.com

116240-01E

Image 32
Contents WHAT TO DO IF YOU SMELL GAS Table of Contents Safety InformationDANGER Carbon monoxide poisoning may lead to deathSafety information ContinuedSafety information ProductIdentification Local CodesProduct Features Pre-Installation PreparationFigure 3 - Fireplace Bottom Dimensions Location and space requirementsContinued ClearancesPre-Installation InstallationPreparation ContinuedFigure 7 - Minimum Clearances for Termination Cap Location of Termination CapD E B L Venting Installation Instructions Venting Installation instructions INSTALLATION PLANNINGContinued Figure 8 - Vent Pipe ConnectionsFigure 10 - Installing Horizontal Vent Cap Figure 11 - Installing Siding StandoffFigure 12 - Connecting Vent Cap with ContinuedGROUND FLOOR INSTALLATION ContinuedSquare Termination VerticalCORNER INSTALLATION SNORKEL TERMINATION INSTALLATIONContinued 90 ElbowHORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWSContinued with Termination at 90 with Fireplaceinstallation for vertical termination Flat Ceiling InstallationFigure 20 - Installing Firestop ContinuedConfiguration Using Two 90 Elbows Configuration Using One 90 ElbowContinued Figure 21 - Vertical VentingConfiguration Using Two 90 Elbows Configuration With No Horizontal RunContinued Vertical Ventingparts list for venting kits and components ContinuedDESA 5/8 Pipe & Vent Kits Number Description Number DescriptionCHECK GAS TYPE Fireplace InstallationInstalling optional blower accessories Figure 28 - Blower Model BKT Model BKT InstallationContinued Installation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Installation Items Needed ContinuedFigure 30 - External Regulator with Vent Pointing Down Propane/LP OnlyContinued CHECKING GAS CONNECTIONSPressure Testing Fireplace Gas Connections Removing Louver PanelsFigure 36 - Removing Louver Panel Removing Glass DoorInstalling lava rock and glowing embers Installing Lava Rock and Glowing Embers, page Figure 40 - Installing the WRC Remote ReceiverFigure 39 - Installing Rear Brick Panel Figure 41 - Installing Battery into Back ofIGNITOR LEAD PILOT24V AC 120V ACfor your safety Read before lighting Operating Fireplacelighting instructions TO TURN OFF GAS TO APPLIANCEsee Troubleshooting, page see Troubleshooting, pageContinued Figure 44 - Correct Pilot Flame PatternCleaning and Maintenance CAUTION Do not vacuum if pieces are hotCleaning and Maintenance TroubleshootingOBSERVED PROBLEM venting systemContinued TROUBLESHOOTINGWiring Diagram, page WARNING If you smell gas Shut off gas supply Replacement Parts Service HintsTechnical Service SpecificationsAccessories 116240-01E 24 22 23 4 1 9 11 3 14 167 8 PARTS LIST illustrated parts breakdown Burner Pan Assembly LIMITED WARRANTY DIRECT-VENTFIREPLACE Warranty InformationKEEP THIS WARRANTY