7.Check to make sure that the power cord is com- pletely clear of the blower wheel and that there are no other foreign objects in blower wheel. Also double check all wire leads and make sure wire routing is not pinched or in a precarious position. Correct accordingly.

8.Turn on power to duplex outlet if previously turned off per the warning in column 1, page 19.

9.Plug in blower power cord to duplex outlet.

10.The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be adjusted by rotating the control knob. To turn off, turn knob fully counterclockwise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically.

11.Peel off the backing paper and stick the sup- plied wiring diagram decal on the firebox bot- tom approximately 12" in front of the blower (see Figure 27, page 20).

Blower Wiring Diagram

Installing Gas Piping to Fireplace Location CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing.

 

 

 

Variable

Fan Switch

 

 

Fan Switch

 

 

 

 

(N.O.)

 

 

Off

1

Black

 

 

 

2

110/115

On

 

Blue

 

 

 

V.A.C. Black

 

Blower

 

 

 

 

 

 

White

 

Motor

Green

Figure 29 - Blower Wiring Diagram for

Thermostat-Controlled Models

Installing Gas Piping to Fireplace Location

Installation Items Needed WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes.

Manual background CAUTION: For propane/LP units, never connect fireplace di- rectly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

Manual background WARNING: For natural gas, never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by local codes)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alterna- tive to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your retailer.

For propane/LP connection only, the installer must supply an external regulator. The external regula- tor will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 30, page 22. Pointing the vent down protects it from freezing rain or sleet.

116240-01E

www.desatech.com

21

Image 21
Contents WHAT TO DO IF YOU SMELL GAS Safety Information Table of ContentsDANGER Carbon monoxide poisoning may lead to deathContinued Safety informationProduct Safety informationIdentification Local CodesPre-Installation Preparation Product FeaturesFigure 3 - Fireplace Bottom Dimensions Location and space requirementsClearances ContinuedInstallation Pre-InstallationPreparation ContinuedLocation of Termination Cap D E B LFigure 7 - Minimum Clearances for Termination Cap Venting Installation Instructions INSTALLATION PLANNING Venting Installation instructionsContinued Figure 8 - Vent Pipe ConnectionsFigure 11 - Installing Siding Standoff Figure 10 - Installing Horizontal Vent CapFigure 12 - Connecting Vent Cap with ContinuedContinued GROUND FLOOR INSTALLATIONSquare Termination VerticalSNORKEL TERMINATION INSTALLATION CORNER INSTALLATIONContinued 90 ElbowUSING TWO 90 ELBOWS HORIZONTAL SYSTEM INSTALLATIONContinued with Termination at 90 with FireplaceFlat Ceiling Installation installation for vertical terminationFigure 20 - Installing Firestop ContinuedConfiguration Using One 90 Elbow Configuration Using Two 90 ElbowsContinued Figure 21 - Vertical VentingConfiguration With No Horizontal Run Configuration Using Two 90 ElbowsContinued Vertical VentingContinued parts list for venting kits and componentsDESA 5/8 Pipe & Vent Kits Number Description Number DescriptionFireplace Installation Installing optional blower accessoriesCHECK GAS TYPE Model BKT Installation ContinuedFigure 28 - Blower Model BKT Installing Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Continued Installation Items NeededFigure 30 - External Regulator with Vent Pointing Down Propane/LP OnlyCHECKING GAS CONNECTIONS ContinuedRemoving Louver Panels Pressure Testing Fireplace Gas ConnectionsFigure 36 - Removing Louver Panel Removing Glass DoorInstalling lava rock and glowing embers Figure 40 - Installing the WRC Remote Receiver Installing Lava Rock and Glowing Embers, pageFigure 39 - Installing Rear Brick Panel Figure 41 - Installing Battery into Back ofPILOT IGNITOR LEAD24V AC 120V ACOperating Fireplace for your safety Read before lightinglighting instructions TO TURN OFF GAS TO APPLIANCEsee Troubleshooting, page see Troubleshooting, pageContinued Figure 44 - Correct Pilot Flame PatternCAUTION Do not vacuum if pieces are hot Cleaning and MaintenanceTroubleshooting Cleaning and MaintenanceOBSERVED PROBLEM venting systemTROUBLESHOOTING Wiring Diagram, pageContinued WARNING If you smell gas Shut off gas supply Service Hints Replacement PartsTechnical Service SpecificationsAccessories 24 22 23 4 1 9 11 3 14 16 7 8116240-01E PARTS LIST illustrated parts breakdown Burner Pan Assembly Warranty Information KEEP THIS WARRANTYLIMITED WARRANTY DIRECT-VENTFIREPLACE