Desa (V)KC42PE installation manual Continued, Clearances

Page 6
Clearances

Pre-Installation

Preparation

Continued

Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior sur- face on the back, sides or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 7.

If you plan on installing a television or enter- tainment center recessed above your fireplace, it is recommended that you maintain a minimum 18" above top of louver opening.

When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 8.

If recessing into a wall, you can avoid extra framing by positioning your fireplace against an already existing framing member.

Do not recess termination cap into a wall or siding.

You may paint the termination cap with 450º F (232º C) heat-resistant paint to coordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks or util- ity buildings within 24" from the front of the termination cap.

Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.

Clearances

Minimum clearances to combustibles for the fire-

place are as follows:

 

 

*Back and sides

 

0"

Perpendicular walls

 

6"

Floor

 

0"

Ceiling to louver opening

42"

Front

 

36"

Top of Standoffs

 

0"

Vent

(See venting instructions

 

for specific venting

clearances.)

Combustible material with a maximum thick- ness of 5/8" may be flush with the top front of fireplace.

*For back and sides of fireplace, do not pack with insulation or other materials. 0" clear- ance to combustible materials are for framing purpose only.

NOTICE: This fireplace is in- tended for use as supplemental heat. Use this fireplace along with your primary heating sys- tem. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using fireplace. This will help circulate the heat throughout the house. In the event of a power outage, you can use this fireplace as a heat source.

www.desatech.com116240-01E

Image 6
Contents WHAT TO DO IF YOU SMELL GAS DANGER Carbon monoxide Table of ContentsSafety Information poisoning may lead to deathSafety information ContinuedIdentification Safety informationProduct Local CodesFigure 3 - Fireplace Bottom Dimensions Product FeaturesPre-Installation Preparation Location and space requirementsContinued ClearancesPreparation Pre-InstallationInstallation ContinuedLocation of Termination Cap D E B LFigure 7 - Minimum Clearances for Termination Cap Venting Installation Instructions Continued Venting Installation instructionsINSTALLATION PLANNING Figure 8 - Vent Pipe ConnectionsFigure 12 - Connecting Vent Cap with Figure 10 - Installing Horizontal Vent CapFigure 11 - Installing Siding Standoff ContinuedSquare Termination GROUND FLOOR INSTALLATIONContinued VerticalContinued CORNER INSTALLATIONSNORKEL TERMINATION INSTALLATION 90 ElbowContinued HORIZONTAL SYSTEM INSTALLATIONUSING TWO 90 ELBOWS with Termination at 90 with FireplaceFigure 20 - Installing Firestop installation for vertical terminationFlat Ceiling Installation ContinuedContinued Configuration Using Two 90 ElbowsConfiguration Using One 90 Elbow Figure 21 - Vertical VentingContinued Configuration Using Two 90 ElbowsConfiguration With No Horizontal Run Vertical VentingDESA 5/8 Pipe & Vent Kits Number Description parts list for venting kits and componentsContinued Number DescriptionFireplace Installation Installing optional blower accessoriesCHECK GAS TYPE Model BKT Installation ContinuedFigure 28 - Blower Model BKT Installing Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Figure 30 - External Regulator with Vent Installation Items NeededContinued Pointing Down Propane/LP OnlyContinued CHECKING GAS CONNECTIONSFigure 36 - Removing Louver Panel Pressure Testing Fireplace Gas ConnectionsRemoving Louver Panels Removing Glass DoorInstalling lava rock and glowing embers Figure 39 - Installing Rear Brick Panel Installing Lava Rock and Glowing Embers, pageFigure 40 - Installing the WRC Remote Receiver Figure 41 - Installing Battery into Back of24V AC IGNITOR LEADPILOT 120V AClighting instructions for your safety Read before lightingOperating Fireplace TO TURN OFF GAS TO APPLIANCEContinued see Troubleshooting, pagesee Troubleshooting, page Figure 44 - Correct Pilot Flame PatternCleaning and Maintenance CAUTION Do not vacuum if pieces are hotOBSERVED PROBLEM Cleaning and MaintenanceTroubleshooting venting systemTROUBLESHOOTING Wiring Diagram, pageContinued WARNING If you smell gas Shut off gas supply Technical Service Replacement PartsService Hints SpecificationsAccessories 24 22 23 4 1 9 11 3 14 16 7 8116240-01E PARTS LIST illustrated parts breakdown Burner Pan Assembly Warranty Information KEEP THIS WARRANTYLIMITED WARRANTY DIRECT-VENTFIREPLACE