Desa CGEFP33PR, CGEFP33NR, EFP33PR, EFP33NR, VTGF33NR, VTGF33PR Installing Logs EFP33PR/EFP33NR

Page 23

INSTALLATION

Installing Logs (EFP33PR/EFP33NR)

23

INSTALLATION

Continued

INSTALLING LOGS (EFP33PR/EFP33NR)

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: Do not remove the warning and in- struction labels attached to the heater base assem- bly. These markings contain important warranty information.

CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to HIGH, check to see if flames contact any log. If so, reposition logs ac- cording to the log installation instructions in this manual. Flames contacting logs will create soot.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place the base of the middle log (#1) in the U-shaped slots of the grate base. The cutout on the right of the middle log should fit over the burner (see Figure 49). Make sure the front of the middle log is resting on the tabs of the grate base and the cut- out area is centered over the burner “U” bend.

2.Locate pegs on the bottom of back log (#2). Slide these pegs into the holes in the grate base behind the burner (see Figure 50).

3.Locate the notches in the bottom of the front log (#3). Place the front log on the grate fingers. Make sure the notches of the front log line up with the grate fingers (see Figure 51).

4.Place crossover log (#4) onto the peg (right) on back log (#2) and into the recess of the middle log (#1) (see Figure 52).

Middle

Back Log (#2)

Log (#1)

 

"U"-

Peg

shaped

Cutout

 

in Base

 

Peg

Burner

 

Figure 49 - Installing Middle

Figure 50 - Installing Back

Log (#1)

Log (#2)

Front

Log (#3)

Crossover

Log (#4)

Notches

Peg

Grate

 

Fingers

Recess

 

Figure 51 - Installing Front

Figure 52 - Installing

Log (#3)

Crossover Log (#4)

For morevisit www..com

108117-01G

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Fireplace Floor Assembly EFP33PR ShownUnpacking Product FeaturesLocal Codes Confined Space and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation Air From Inside Building Determining FRESH-AIR Flow for Heater LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors InstallationCheck GAS Type Installation ClearancesInstallation Sequence Removing Fireplace Screen and Floor AssemblyRelocating Wall Switch Electrical Connections for Power CordRelocating Switch and Wall Plate Ing from inside mantel see Figure Installing Variable Speed Blower AccessoryAttaching Speed Control to Firebox VTGF33NR/ VTGF33PR Shown Operating the Blower Installing Thermostatic Blower AccessoryAttaching Speed Control VTGF33NR/VTGF33PR Shown Installing GAS Piping to Fireplace Location Installation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Conventional Fireplace InstallationInstalling Cabinet Mantel BUILT-IN Fireplace InstallationAssembling and Attaching Optional Brass Trim Mantel Clearances for Built-In InstallationInstalling Hood Installing Logs VTGF33NR/VTGF33PRInstalling Installing Logs CGEFP33PR/CGEFP33NRInstalling Logs EFP33PR/EFP33NR Operating Fireplace Installing Battery Into RemoteFor Your Safety Read Before Lighting Installing ScreenTo Turn OFF GAS to Appliance Normal Lighting InstructionsOptional Blower Operation Manual Lighting Instructions for Electrical Power OutageShutting Off Heater When Manually Lit Main Burner Inspecting BurnersPilot Flame Pattern Front Burner Flame Pattern VTGF33 Series onlyLogs Cleaning MaintenanceCleaning Burner Injector Holder Cleaning Pilot AIR Inlet HoleObserved Problem Possible Cause Remedy TroubleshootingFor Com Gas leak. See Warning statement Replacement Parts SpecificationsService Hints Technical ServiceEFP33NR/EFP33PR and CGEFP33NR/CGEFP33PR VTGF33NR/VTGF33PR Wiring DiagramIllustrated Parts Breakdown KEY Part Number EFP33 CGEFP33 Description QTY Parts ListFirebox EFP33PR/NR CGEFP33PR/NR7 KEY Part Number Description QTY Firebox EFP33PR/NR CGEFP33PR/NRRemote Control LOG Base Assembly VTGF33PR and VTGF33NR Shown 101004-08 Front Burner Injector Natural 101004-02 Firebox VTGF33NR VTGF33PR Firebox VTGF33NR and VTGF33PR Accessories Firebox Brick Liner G8001 Series Laminate Trim for Hearth or MantelCorner Hearth Base Slim Hearth BaseFor . .com Diameter Holes TemplatesThis page Intentionally Left Blank Owners Registration Form Postage Required 108117-01G Not a UPC