Desa CGEFP33PR, CGEFP33NR, EFP33PR, EFP33NR, VTGF33NR, VTGF33PR Installing Logs VTGF33NR/VTGF33PR

Page 21

INSTALLATION

Assembling And Attaching Optional Brass Trim (Cont.)

Installing Hood

Installing Logs (VTGF33NR/VTGF33PR)

21

INSTALLATION

Continued

Set Screws

INSTALLING LOGS (VTGF33NR/VTGF33PR)

Side Brass

Adjusting

Trim

Plate

Slot

Shim

Slot

Mitered Edge

Figure 38 - Assembling Brass Trim

Assembled

Brass Trim

Top Brass Trim

Trim

Hanging

Screws

Hanging Notches on Trim

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: Do not remove the warning and in- struction labels attached to the heater base assem- bly. These markings contain important warranty in- formation.

CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, reposition logs ac- cording to the log installation instructions in this manual. Flames contacting logs will create soot.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1. Place front logs (#1a and #1b) on top of the grate. Make sure

the notches in the bottom of the log fit over the grate prongs

(see Figure 41). Push back of log flush with metal grate bar.

Figure 39 - Attaching Brass Trim to Fireplace (EFP33PR Shown)

INSTALLING HOOD

Install hood to top of firebox as shown in Figure 40. Use 3 Phillips screws provided.

Figure 40 - Installing Hood to Firebox (EFP33PR Shown)

2.

Rest middle log (#2) behind metal posts on front burner. Make

 

sure the grooves in the bottom of the log fit over the grate.

 

Bring the log forward next to the metal posts (see Figure 42).

3.

Slide the grooves in the back of the rear log (#3) against the

 

rear grate prongs. Make sure the peg on the log is on top (see

 

Figure 43, page 22).

4.

Place the crossover log (#4) on the rear log and the middle log.

 

Make sure the peg on the rear log is in the hole in the bottom

 

of the crossover log. The crossover log should fit in the cutout

 

of the middle log (see Figure 44, page 22).

Front Log (#1a)

Middle Log (#2)

 

Front Log

 

(#1b)

 

Groove

Notch

Metal

 

 

Post

Grate

 

Prongs

Groove

Metal

Grate

Grate Bar

Metal Post

Figure 41 - Installing Front

Figure 42 - Installing Middle

Logs (#1a and #1b)

Log (#2)

For morevisit www..com

108117-01G

Image 21
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Fireplace Floor Assembly EFP33PR ShownProduct Features Local CodesUnpacking Providing Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation AIR Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingVentilation Air From Outdoors InstallationInstallation Sequence Installation ClearancesRemoving Fireplace Screen and Floor Assembly Check GAS TypeRelocating Wall Switch Electrical Connections for Power CordRelocating Switch and Wall Plate Ing from inside mantel see Figure Installing Variable Speed Blower AccessoryAttaching Speed Control to Firebox VTGF33NR/ VTGF33PR Shown Operating the Blower Installing Thermostatic Blower AccessoryAttaching Speed Control VTGF33NR/VTGF33PR Shown Installing GAS Piping to Fireplace Location Installation Items Needed Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Conventional Fireplace InstallationInstalling Cabinet Mantel BUILT-IN Fireplace InstallationAssembling and Attaching Optional Brass Trim Mantel Clearances for Built-In InstallationInstalling Hood Installing Logs VTGF33NR/VTGF33PRInstalling Installing Logs CGEFP33PR/CGEFP33NRInstalling Logs EFP33PR/EFP33NR For Your Safety Read Before Lighting Installing Battery Into RemoteInstalling Screen Operating FireplaceTo Turn OFF GAS to Appliance Normal Lighting InstructionsManual Lighting Instructions for Electrical Power Outage Shutting Off Heater When Manually LitOptional Blower Operation Pilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern VTGF33 Series only Main BurnerCleaning Burner Injector Holder Cleaning MaintenanceCleaning Pilot AIR Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingFor Com Gas leak. See Warning statement Service Hints SpecificationsTechnical Service Replacement PartsEFP33NR/EFP33PR and CGEFP33NR/CGEFP33PR VTGF33NR/VTGF33PR Wiring DiagramIllustrated Parts Breakdown KEY Part Number EFP33 CGEFP33 Description QTY Parts ListFirebox EFP33PR/NR CGEFP33PR/NR7 KEY Part Number Description QTY Firebox EFP33PR/NR CGEFP33PR/NRRemote Control LOG Base Assembly VTGF33PR and VTGF33NR Shown 101004-08 Front Burner Injector Natural 101004-02 Firebox VTGF33NR VTGF33PR Firebox VTGF33NR and VTGF33PR Accessories Corner Hearth Base Laminate Trim for Hearth or MantelSlim Hearth Base Firebox Brick Liner G8001 SeriesFor . .com Diameter Holes TemplatesThis page Intentionally Left Blank Owners Registration Form Postage Required 108117-01G Not a UPC