Desa CGEFP33PR, CGEFP33NR, EFP33PR, EFP33NR, VTGF33NR, VTGF33PR Relocating Wall Switch

Page 9

INSTALLATION

Removing Fireplace Screen And Floor Assembly (Cont.)

Electrical Connections for Power Cord

Relocating Wall Switch

9

INSTALLATION

Continued

Flexible Gas Line

Screws

Fireplace Floor

Assembly

Figure 6 - Removing Fireplace Floor Assembly (VTGF33N/PR Shown)

ELECTRICAL CONNECTIONS FOR POWER CORD

This fireplace operates on 120 VAC, 60 Hz power. An electrical power cord is supplied with this unit.

For Mantel Installation

1.Determine from which side of the fireplace the power cord will exit. Locate the 1.5" diameter hole near the center of floor sup- port bracket on appropriate side of lower cavity (see Figure 7).

2.Locate power cord. Remove wire tie or tape holding plug end of power cord.

3.Power cord has 2 plastic hole bushings threaded onto it. Route cord's 3-prong plug through the 1.5" diameter hole in appro- priate floor support bracket.

4.Push first plastic bushing completely through hole. Squeeze bushing as needed to do this.

5.Install the second plastic bushing into the hole in the floor sup- port bracket by snapping into place.

6.Route the 3-prong plug through the 1.5" hole in fireplace outer casing.

7.Install the first plastic bushing into this hole by snapping into place.

8.After you have connected to gas supply and checked your gas connections (see pages 15 through 18), plug power cord into any convenient 3-prong grounded wall receptacle near fireplace.

For Recessed Installation

If an outlet is not installed in fireplace, install model GA3555 - Outlet Kit with Cover. This kit will supply a convenient 3-prong grounded electrical outlet for power. Refer to installation manual provided with this optional accessory for instructions on wiring. Note: A qualified installer must make all electrical connections.

Hole in Floor

Hole in Outer

Support Bracket

Casing

Bushings

Power Cord

Figure 7 - Routing Power Cord

RELOCATING WALL SWITCH

Note: The decorative wall switch plate supplied is white. The wall switch plate may be painted to match your decor.

The push-button switch and decorative wall plate assembly sup- plied with your fireplace is pre-mounted at the factory in the lower cavity of the fireplace. You may relocate this switch/plate assembly to a more convenient location such as the side of your mantel or directly onto the wall near the fireplace. To mount the wall switch/ plate assembly, you must first cut openings in the mantel or wall where the switch will be located.

Note: If you choose to relocate the wall switch, do so before final installation into a mantel or recessing into a wall. If you are installing an optional blower accessory, install it at the same time you relocate the wall switch.

CAUTION: The wall switch must never be mounted directly above the fireplace where heat may damage it. If you relocate wall switch from lower fireplace cavity, it must be mounted either on side wall of mantel or on wall to side of fireplace.

For Recessed Installation

If fireplace is to be recessed into a wall (see Built-In Fireplace Installation, pages 19 and 20), we recommend mounting wall switch to left side of fireplace. The wall switch should be mounted approximately 12" from left edge of fireplace, and less than 60" from the floor. IMPORTANT: Do not locate wall switch directly in front of wall stud - there must be room behind wall board for wires from switch. If you choose to locate wall switch to right side of fireplace, the length of the cord restricts you to less than 6" from right edge of fireplace and less than 48" from floor.

For morevisit www..com

108117-01G

Image 9
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Fireplace Floor Assembly EFP33PR ShownProduct Features Local CodesUnpacking Providing Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation AIR Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingVentilation Air From Outdoors InstallationInstallation Sequence Installation ClearancesRemoving Fireplace Screen and Floor Assembly Check GAS TypeRelocating Wall Switch Electrical Connections for Power CordRelocating Switch and Wall Plate Ing from inside mantel see Figure Installing Variable Speed Blower AccessoryAttaching Speed Control to Firebox VTGF33NR/ VTGF33PR Shown Operating the Blower Installing Thermostatic Blower AccessoryAttaching Speed Control VTGF33NR/VTGF33PR Shown Installing GAS Piping to Fireplace Location Installation Items Needed Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Conventional Fireplace InstallationInstalling Cabinet Mantel BUILT-IN Fireplace InstallationAssembling and Attaching Optional Brass Trim Mantel Clearances for Built-In InstallationInstalling Hood Installing Logs VTGF33NR/VTGF33PRInstalling Installing Logs CGEFP33PR/CGEFP33NRInstalling Logs EFP33PR/EFP33NR For Your Safety Read Before Lighting Installing Battery Into RemoteInstalling Screen Operating FireplaceTo Turn OFF GAS to Appliance Normal Lighting InstructionsManual Lighting Instructions for Electrical Power Outage Shutting Off Heater When Manually LitOptional Blower Operation Pilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern VTGF33 Series only Main BurnerCleaning Burner Injector Holder Cleaning MaintenanceCleaning Pilot AIR Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingFor Com Gas leak. See Warning statement Service Hints SpecificationsTechnical Service Replacement PartsEFP33NR/EFP33PR and CGEFP33NR/CGEFP33PR VTGF33NR/VTGF33PR Wiring DiagramIllustrated Parts Breakdown KEY Part Number EFP33 CGEFP33 Description QTY Parts ListFirebox EFP33PR/NR CGEFP33PR/NR7 KEY Part Number Description QTY Firebox EFP33PR/NR CGEFP33PR/NRRemote Control LOG Base Assembly VTGF33PR and VTGF33NR Shown 101004-08 Front Burner Injector Natural 101004-02 Firebox VTGF33NR VTGF33PR Firebox VTGF33NR and VTGF33PR Accessories Corner Hearth Base Laminate Trim for Hearth or MantelSlim Hearth Base Firebox Brick Liner G8001 SeriesFor . .com Diameter Holes TemplatesThis page Intentionally Left Blank Owners Registration Form Postage Required 108117-01G Not a UPC