PARTS LIST

Remote Control Log Base Assembly EFP33PR/NR and CGEFP33PR/NR

35

PARTS LIST

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replace- ment Parts on page 32 of this manual.

KEY

PART NUMBER

PART NUMBER

 

 

NO.

EFP33

CGEFP33

DESCRIPTION

QTY.

1

110089-01

110090-02

Middle Log (#1)

1

2

110089-02

110090-03

Back Log (#2)

1

3

110089-03

110090-01

Front Log (#3)

1

4

110089-04

110090-04

Crossover Log (#4)

1

5

104286-02

104286-02

ODS Pilot (Propane/LP)

1

 

104285-02

104285-02

ODS Pilot (Natural)

1

6

098249-01

098249-01

ODS Nut

2

7

099387-05

099387-05

Pilot Tube

1

8

101973-02

101973-02

Inlet Tube

1

9

107572-01

107572-01

Burner Outlet Tube

1

10

102843-01

102843-01

Burner Clip

1

11

099056-19

099056-19

Burner Orifice Injector (Propane/LP)

1

 

099056-26

099056-26

Burner Orifice Injector (Natural)

1

12

102772-01

102772-01

Burner

1

13

M10908-2

M10908-2

Screw, Self-Tapping

2

14

104236-01CK

104236-01CK

Painted Base Assy

1

15

104238-03CK

104238-03CK

Firebox Bottom

1

16

107573-01

107573-01

Valve Bracket

1

17

107559-02

107559-02

Gas Control Valve (Propane/LP)

1

 

107559-01

107559-01

Gas Control Valve (Natural)

1

18

102445-01

102445-01

Piezo Ignitor

1

19

102334-01

102334-01

Palnut Fastener

1

20

107562-01

107562-01

Switch and Wire Assembly

1

21

107685-01

107685-01

Bracket, Switch and Piezo

1

22

101628-03

101628-03

Flexible Connector

1

23

098544-01

098544-01

Wire Support Clip

1

24

099415-13

099415-13

Pressure Regulator (Propane/LP)

1

 

099415-12

099415-12

Pressure Regulator (Natural)

1

25

097809-03

097809-03

Fitting 3/8" Flare to 1/2" NPT

1

26

107687-01

107687-01

Electrode Bracket

1

27

103904-02

103904-02

Electrode

1

28

100694-01

100694-01

Screw, #6 x 1 1/4" PH

2

29

107560-01

107560-01

Magnetic Manual Override Handle

1

30

107563-01

107563-01

Wall Switch and Cord

1

31

107558-01

107558-01

Wall Switch Decorative Plate

1

32

102349-02

102349-02

Support, PCB

4

33

107561-01

107561-01

Wall Plate Decal

1

34

107564-01

107564-01

Remote Control

1

35

107565-01

107565-01

Receiver Assembly

1

36

107565-02

107565-02

Sensor Assembly

1

37

107566-01

107566-01

Module, Control Board

1

38

098271-08

098271-08

Ignitor Cable

1

39

107568-01

107568-01

Main Power Cable

1

40

098219-37

098219-37

Power Cord

1

41

101629-01

101629-01

1.5" Bushing

2

42

098303-02

098303-02

Screw, #6

2

43

107743-01

107743-01

Thermocouple Wire

1

44

107847-01

107847-01

Screw, #6019 x 1/4"

2

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

 

 

 

 

 

19724000

19724000

Cable Tie

4

 

901056-01

901056-01

Fitting, 3/8" NPT

1

 

107736-01

107736-01

Wall Plate Assembly Kit

1

 

 

 

(Contains Items 31, 33, 44)

 

 

107737-01

107737-01

Wall Switch Assembly Kit

1

 

 

 

(Contains Items 28, 30, 31, 33, 44)

 

 

 

 

 

 

For morevisit www..com

108117-01G

Image 35
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Fireplace Floor Assembly EFP33PR ShownUnpacking Product FeaturesLocal Codes Confined Space and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation Air From Inside Building Determining FRESH-AIR Flow for Heater LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors InstallationCheck GAS Type Installation ClearancesInstallation Sequence Removing Fireplace Screen and Floor AssemblyRelocating Wall Switch Electrical Connections for Power CordRelocating Switch and Wall Plate Ing from inside mantel see Figure Installing Variable Speed Blower AccessoryAttaching Speed Control to Firebox VTGF33NR/ VTGF33PR Shown Operating the Blower Installing Thermostatic Blower AccessoryAttaching Speed Control VTGF33NR/VTGF33PR Shown Installing GAS Piping to Fireplace Location Installation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Conventional Fireplace InstallationInstalling Cabinet Mantel BUILT-IN Fireplace InstallationAssembling and Attaching Optional Brass Trim Mantel Clearances for Built-In InstallationInstalling Hood Installing Logs VTGF33NR/VTGF33PRInstalling Installing Logs CGEFP33PR/CGEFP33NRInstalling Logs EFP33PR/EFP33NR Operating Fireplace Installing Battery Into RemoteFor Your Safety Read Before Lighting Installing ScreenTo Turn OFF GAS to Appliance Normal Lighting InstructionsOptional Blower Operation Manual Lighting Instructions for Electrical Power OutageShutting Off Heater When Manually Lit Main Burner Inspecting BurnersPilot Flame Pattern Front Burner Flame Pattern VTGF33 Series onlyLogs Cleaning MaintenanceCleaning Burner Injector Holder Cleaning Pilot AIR Inlet HoleObserved Problem Possible Cause Remedy TroubleshootingFor Com Gas leak. See Warning statement Replacement Parts SpecificationsService Hints Technical ServiceEFP33NR/EFP33PR and CGEFP33NR/CGEFP33PR VTGF33NR/VTGF33PR Wiring DiagramIllustrated Parts Breakdown KEY Part Number EFP33 CGEFP33 Description QTY Parts ListFirebox EFP33PR/NR CGEFP33PR/NR7 KEY Part Number Description QTY Firebox EFP33PR/NR CGEFP33PR/NRRemote Control LOG Base Assembly VTGF33PR and VTGF33NR Shown 101004-08 Front Burner Injector Natural 101004-02 Firebox VTGF33NR VTGF33PR Firebox VTGF33NR and VTGF33PR Accessories Firebox Brick Liner G8001 Series Laminate Trim for Hearth or MantelCorner Hearth Base Slim Hearth BaseFor . .com Diameter Holes TemplatesThis page Intentionally Left Blank Owners Registration Form Postage Required 108117-01G Not a UPC