1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, ver- miculite, or rock wool. Using these added items can cause soot- ing. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 28.

8.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 7. If fireplace keeps shutting off, see Trouble- shooting, pages 29 through 31.

10.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the fireplace and to replace any part of the control sys- tem and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servicing. Only a quali- fied service person should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems with propane/LP units, do not use propane/LP fuel tanks of less than 100 lb. capacity.

17.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

Manual

 

Log Set

Override

 

 

Handle

 

 

Remote

Piezo

 

Control

 

Ignitor

Manual Ignition

 

 

 

 

Wall Switch/Plate

Bypass Switch

Figure 1 - Fireplace Floor Assembly (EFP33PR Shown)

Top Outer

Casing

Top Louver

Assembly

Firebox

Hood

Firebox Support

Screen

Assembly

Blower

Bottom Louver Assembly

Assembly(Optional)

Figure 2 - Fireplace (EFP33PR Shown)

For morevisit www..com

108117-01G

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Fireplace Floor Assembly EFP33PR ShownProduct Features Local CodesUnpacking Confined Space and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation Air From Inside Building Determining FRESH-AIR Flow for Heater LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors InstallationCheck GAS Type Installation ClearancesInstallation Sequence Removing Fireplace Screen and Floor AssemblyRelocating Wall Switch Electrical Connections for Power CordRelocating Switch and Wall Plate Ing from inside mantel see Figure Installing Variable Speed Blower AccessoryAttaching Speed Control to Firebox VTGF33NR/ VTGF33PR Shown Operating the Blower Installing Thermostatic Blower AccessoryAttaching Speed Control VTGF33NR/VTGF33PR Shown Installing GAS Piping to Fireplace Location Installation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Conventional Fireplace InstallationInstalling Cabinet Mantel BUILT-IN Fireplace InstallationAssembling and Attaching Optional Brass Trim Mantel Clearances for Built-In InstallationInstalling Hood Installing Logs VTGF33NR/VTGF33PRInstalling Installing Logs CGEFP33PR/CGEFP33NRInstalling Logs EFP33PR/EFP33NR Operating Fireplace Installing Battery Into RemoteFor Your Safety Read Before Lighting Installing ScreenTo Turn OFF GAS to Appliance Normal Lighting InstructionsManual Lighting Instructions for Electrical Power Outage Shutting Off Heater When Manually LitOptional Blower Operation Main Burner Inspecting BurnersPilot Flame Pattern Front Burner Flame Pattern VTGF33 Series onlyLogs Cleaning MaintenanceCleaning Burner Injector Holder Cleaning Pilot AIR Inlet HoleObserved Problem Possible Cause Remedy TroubleshootingFor Com Gas leak. See Warning statement Replacement Parts SpecificationsService Hints Technical ServiceEFP33NR/EFP33PR and CGEFP33NR/CGEFP33PR VTGF33NR/VTGF33PR Wiring DiagramIllustrated Parts Breakdown KEY Part Number EFP33 CGEFP33 Description QTY Parts ListFirebox EFP33PR/NR CGEFP33PR/NR7 KEY Part Number Description QTY Firebox EFP33PR/NR CGEFP33PR/NRRemote Control LOG Base Assembly VTGF33PR and VTGF33NR Shown 101004-08 Front Burner Injector Natural 101004-02 Firebox VTGF33NR VTGF33PR Firebox VTGF33NR and VTGF33PR Accessories Firebox Brick Liner G8001 Series Laminate Trim for Hearth or MantelCorner Hearth Base Slim Hearth BaseFor . .com Diameter Holes TemplatesThis page Intentionally Left Blank Owners Registration Form Postage Required 108117-01G Not a UPC