Desa (V)V42N Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

Page 26

26

OPERATING FIREPLACE

For Your Safety Read Before Lighting

Lighting Instructions

To Turn Off Gas To Appliance

Manual Lighting Procedure

OPERATING FIREPLACE

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Open lower louver panel.

3.Disconnect the wire that runs from TH to TPTH from the control valve.

4.Turn off all electric power to the fireplace.

5.Push in gas control knob slightly and turn clockwise to “OFF”.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not re- quire accessing for lighting.

8.Turn gas control knob counterclockwise to “PILOT”.

9.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

10.Reconnect the wire that runs from TH to TPTH to the control valve.

11.Turn on all electric power to the fireplace.

12.Turn gas control knob counterclockwise to “ON”.

13.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

14.Close lower louver panel.

 

Gas Control

Variable Control Knob

 

 

 

Knob

 

Piezo

 

 

Ignitor

ILOT

IH

O

O

 

P

 

F

N

 

F

 

 

 

LO

Figure 52 - Control Valve

TO TURN OFF GAS TO APPLIANCE

1.Open lower louver panel.

2.Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise to “OFF”.

5.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1. Turn gas control knob clockwise to the PILOT position.

2.Set selector switch in the OFF position.

MANUAL LIGHTING PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, page 23.)

2.Follow steps 1 through 8 under Lighting Instructions.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Fol- low steps 10 through 14 under Lighting Instructions.

5.Replace glass door (see Removing/Replacing Glass Door,

page 23).

For..com

108861-01D

Image 26
Contents For Your Safety What to do if YOU Smell GAS TM OWNER’S Operation Installation ManualFor Your Safety Table of Contents Safety InformationSafety Information Product Identification Local CodesLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Siding Standoff Models 36 3/ 4 min Horizontal Termination ConfigurationsVertical Horizontal H Models 32 3/ 4 min Corner Installation Horizontal System Installation Using TWO 90 Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowDesa International Elbows High Altitude InstallationDesa International 5/8 Pipe & Vent Kits Vertical VentingDesa International Venting Accessories Desa International TerminationsModel BK Installation Fireplace InstallationInstalling Optional Blower Accessories Check GAS TypeModel BKT Installation Blower Model BKTInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Pressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Checking Gas Joints for Propane/LP Gas FireplaceReplace the switch bracket Removing Louver Panels Cleaning Glass Door REMOVING/REPLACING Glass Door Removing Glass DoorsInstalling LOGS, Lava Rock and Glowing Embers Installing Rear Brick PanelInstalling Log No 36 and 42 Series and Log No 42 Series Only Operating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsCghrcta Series Operation Optional Remote OperationCghrc Series Operation Inspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveTechnical Service Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Parts List CHDV36NR Description QTYIllustrated Parts Breakdown KEY Part Number Description QTY VV42P, V42PS, VV42PH, CHDV42NR Refractory Brick Panels CHDV42NR Illustrated Parts Breakdown KEY Part Number Description QTY Accessories Receiver and HAND-HELD ON/OFF Remote Control KIT Ghrc Series Wall Mounted Thermostat ControlWarranty Information