VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

9

VENTING INSTALLATION INSTRUCTIONS

Continued

WARNING: Do not recess vent termination into any wall. This will cause a fire hazard.

6.Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1/2" round hole and attach to the exte- rior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal be- tween it and the outside wall. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

Combustible Exterior Wall: For vinyl siding, stucco, or wood exteriors, a siding standoff must be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging the siding materials. Siding material must be cut to accommodate standoff. Bolt the vent cap to the stand- off. Apply non-hardening mastic around outside edge of stand- off. Position the standoff/cap assembly in the center of the 10 3/4" square hole and attach to exterior wall with wood screws provided (see Figure 11). The siding standoff must sit flush against the exterior fascia material.

7.Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12).

8.Carefully move fireplace, with vent assembly attached, toward wall and insert vent pipe into horizontal termination. The pipe overlap should be a minimum of 11/4".

Apply Mastic to

All Four Sides

Cut Siding Away to Fit Standoff

Standoff

Wood Screw

Vent Cap

Screws

Apply Mastic

to All Four Sides

Figure 11 - Installing Siding Standoff

Interior Wall

Surface

Wall

Firestop

Vent Cap

Horizontal

(Horizontal

Vent Pipe

Termination)

 

Vent Cap

Screw

Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe

Wood Screw

Figure 10 - Installing Horizontal Vent Cap

For morevisit www..com

108861-01D

Image 9
Contents TM OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Horizontal Termination Configurations Vertical Horizontal H Models 32 3/ 4 minModels 36 3/ 4 min Corner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO 90 ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsDesa International 5/8 Pipe & Vent Kits High Altitude InstallationDesa International Elbows Vertical VentingDesa International Terminations Desa International Venting AccessoriesInstalling Optional Blower Accessories Fireplace InstallationModel BK Installation Check GAS TypeBlower Model BKT Model BKT InstallationInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket REMOVING/REPLACING Glass Door Cleaning Glass DoorRemoving Louver Panels Removing Glass DoorsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No 36 and 42 Series and Log No 42 Series Only Manual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOptional Remote Operation Cghrc Series OperationCghrcta Series Operation Pilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service SpecificationsIllustrated Parts Breakdown CHDV36NR Description QTY Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY VV42P, V42PS, VV42PH, CHDV42NR Refractory Brick Panels CHDV42NR Illustrated Parts Breakdown KEY Part Number Description QTY Accessories Wall Mounted Thermostat Control Receiver and HAND-HELD ON/OFF Remote Control KIT Ghrc SeriesWarranty Information

(V)V42P, CHDV42NR, (V)V36P, (V)V42N, CHDV36NR specifications

Desa (V)V42N, CHDV36NR, (V)V36P, (V)V42P, and CHDV42NR represent a range of cutting-edge technological innovations designed for modern heating solutions. These models exemplify the combination of efficiency, versatility, and advanced control features that cater to diverse user needs in both residential and commercial spaces.

One of the standout features of these models is their energy efficiency. Utilizing the latest in burner technology, they are engineered to provide robust heating with minimal fuel consumption. This not only helps in reducing energy bills but also supports environmentally friendly practices by lowering carbon emissions.

The Desa (V)V42N model is particularly notable for its smart thermostat compatibility. It allows users to integrate their heating system with smart home technologies, enabling remote access and control via mobile applications. This feature ensures users can monitor and adjust their heating settings from anywhere, enhancing convenience and comfort.

In contrast, the CHDV36NR model is designed with a focus on aesthetics and ambiance. This model incorporates a modern design with sleek finishes that can seamlessly blend into various interior styles. Its unique viewing window offers a stunning display of flames, creating a captivating focal point in any room.

For those looking for adaptable heating solutions, the (V)V36P and (V)V42P models are equipped with modular capabilities. These designs allow for easy installation and expansion, accommodating different room sizes and heating needs. Moreover, they feature advanced fan systems that distribute heat evenly, ensuring consistent warmth throughout the space.

The CHDV42NR brings another layer of technology with its dual-fuel capability, allowing users to choose between natural gas and propane. This flexibility is particularly advantageous in regions where fuel availability may vary, ensuring reliable performance regardless of the energy source.

Overall, the Desa (V)V42N, CHDV36NR, (V)V36P, (V)V42P, and CHDV42NR models showcase a robust combination of efficiency, advanced technology, and user-friendly features. Whether enhancing indoor comfort with smart technology, aesthetics, or adaptability, these products set a benchmark in the heating solution market. They are perfect for those seeking reliable performance and modern design in their heating systems.