Desa (V)V42P, (V)V42N, (V)V36P, CHDV36NR installation manual Refractory Brick Panels CHDV42NR

Page 39

PARTS LIST

(V)V42N, (V)V42NS, (V)V42NH, (V)V42P, (V)V42PS, (V)V42PH, CHDV42NR

39

PARTS LIST

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

KEY

(V)V42N,

(V)V42NS, (V)V42NH,

 

 

 

 

NO.

(V)V42P

(V)V42PS, (V)V42PH

CHDV42NR

DESCRIPTION

QTY.

 

 

 

 

 

 

 

 

1

**

**

**

Firebox Assembly

1

 

2

**

**

**

Face Weldment

1

 

3

108328-01

108328-01

108328-01

Door Assembly

1

 

 

 

 

___

(V and CHDV Models Only)

 

 

 

108328-02

108328-02

Door Assembly (VV Models Only)

1

 

 

 

 

4

108331-01

108331-01

108331-01

Top Louver Assy

1

 

5

108331-02

108331-02

108331-02

Bottom Louver Assy

1

 

6

**

**

**

Fireplace Top

1

 

7

**

**

**

Fireplace Top Insulation

1

 

8

**

**

**

Fireplace Surround

1

 

9

109082-02

109082-01

109082-01

Heat Shield

1

 

10

___

See Below

See Below

Top Refractory Brick Panel

1

 

___

 

11

See Below

See Below

Left Refractory Brick Panel

1

 

___

 

12

See Below

See Below

Rear Refractory Brick Panel

1

 

___

 

13

See Below

See Below

Right Refractory Brick Panel

1

 

 

 

14

108374-01

108374-01

108374-01

Burner Base Gasket

1

 

15

108455-01

108455-01

108455-01

Screen Rod

1

 

16

108740-01

108740-01

108740-01

Screen

2

 

17

11418

11418

11418

Push-On Nut

2

 

18

14123

14123

14123

Strain Relief

1

 

19

21171

21171

21171

Gas Knock-Out Cover

2

 

20

24353

24353

24353

Handy Box Assembly

1

 

21

24460

24460

24460

Gas Conduit Assembly

1

 

22

108329-01

108329-01

108329-01

Burner Assembly (Natural Gas)

1

 

 

108329-02

108329-02

___

Burner Assembly (Propane/LP Gas)

1

 

 

 

 

 

 

 

 

(See pages 38 and 39)

 

 

23

108778-01

108778-01

108778-01

Log Set

1

 

23-1

109396-01

109396-01

109396-01

Front Log (Log 1)

1

 

23-2

109397-01

109397-01

109397-01

Rear Log (Log 2)

1

 

23-3

109398-01

109398-01

109398-01

Crossover Log (Log 3)

1

 

23-4

109399-01

109399-01

109399-01

Top Log (Log 4)

1

 

23-5

109400-01

109400-01

109400-01

Left Log (Log 5)

1

 

23-6

109401-02

109401-02

109401-02

Right Log (Log 6)

1

 

23-7

109401-01

109401-01

109401-01

Base Log (Log 7)

1

 

 

 

 

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

25487

27253

55240

___

___

25487

27253

55240

___

___

25487

27253

55240 BKT PCDM-42V

Lava Rock/Bag Assy

Notice Label

Vent Label

Blower Kit

Conversion Kit

1

1

1

1

1

REFRACTORY BRICK PANELS

 

CHDV42NR,

 

 

 

 

V42NS, V42PS

VV42NS, VV42PS

V42NH, V42PH

VV42NH, VV42PH

DESCRIPTION

QTY

108352-02

108352-01

108356-02

108356-01

Top Refractory Brick Panel

1

108354-02

108354-01

108358-02

108358-01

Left Refractory Brick Panel

1

108351-02

108351-01

108355-02

108355-01

Rear Refractory Brick Panel

1

108353-02

108353-01

108357-02

108357-01

Right Refractory Brick Panel

1

 

 

 

 

 

 

** Part not available for field replacement.

For morevisit www..com

108861-01D

Image 39
Contents TM OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Horizontal Termination Configurations Vertical Horizontal H Models 32 3/ 4 minModels 36 3/ 4 min Corner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO 90 ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationDesa International 5/8 Pipe & Vent Kits Desa International ElbowsDesa International Terminations Desa International Venting AccessoriesCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationBlower Model BKT Model BKT InstallationInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket Removing Glass Doors Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No 36 and 42 Series and Log No 42 Series Only Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceOptional Remote Operation Cghrc Series OperationCghrcta Series Operation Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown CHDV36NR Description QTY Parts List Illustrated Parts Breakdown KEY Part Number Description QTY VV42P, V42PS, VV42PH, CHDV42NR Refractory Brick Panels CHDV42NR Illustrated Parts Breakdown KEY Part Number Description QTY Accessories Wall Mounted Thermostat Control Receiver and HAND-HELD ON/OFF Remote Control KIT Ghrc SeriesWarranty Information