TROUBLESHOOTING

23

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Yellow flame in front burner during burner

1.

Not enough air

1.

Check burner(s) for dirt and debris. If

combustion

 

 

 

found, clean burner(s) (see Cleaning and

 

 

 

 

Maintenance, page 19)

 

2.

Gas regulator defective

2.

Replace gas regulator

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Low fuel supply (propane/LP only)

 

3.

Gas leak. See Warning statement

 

 

at top of page

1.Open window to ventilate room. Stop us- ing odor causing products while heater is running

2.Refill supply tank (propane/LP only)

3.Locate and correct all leaks (see Check- ing Gas Connections, page 13)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 19)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

at top of page

 

ing Gas Connections, page 13)

 

2.

Control valve or gas control defective

2.

Replace control valve or gas control

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement

 

 

at top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 13)

Dark residue on logs inside of their fireplace

1.

Improper log placement

1.

Properly locate logs (see Installing Logs,

Note: After removing all causes of residue

 

 

 

pages 14 and 15)

deposits, completely clean fireplace and ap-

2.

Drafts or other air currents affecting

2.

Eliminate source of drafts around heater

pliance off residue before reusing appliance

 

flame pattern

 

 

 

3.

Air holes at burner inlet blocked

3.

Clean out air holes at burner inlet. Peri-

 

 

 

 

odically repeat as needed

 

4.

Burner flame holes blocked

4.

Remove blockage

For more

 

visit www.

.com

107172-01J

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Log Base Assembly VSGF33NRA ShownAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Electrical Hookup InstallationInstalling Hood Check GAS TypeAssembling and Attaching Optional Brass Trim Installation ClearancesConventional Fireplace Installation Included with Mantel AccessoryPlacing Hearth Base Accessory Against Wall Mantel Clearances for Built-In Installation BUILT-IN Fireplace InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationGas Connection Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Place front log on top of the grate. Make sure the notches Installing Fireplace Screen Lighting Instructions For Your Safety Read Before LightingOperating Fireplace ON/OFF Series Models Ghrcb and Cghrcb Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationPilot Flame Pattern Inspecting BurnersOptional Blower Operation Front Burner Flame Pattern Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Main BurnerModels EFS33NR, EFS33NRA, VSGF33NR, and VSGF33NRA Wiring DiagramSpecifications LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, For more Visit www Com Illustrated Parts Breakdown Not a field replaceable part Parts ListModels EFS33NR, EFS33NRA, VSGF33NR, VSGF33NRA KEY Part Number Description QTY Accessories Laminate Trim for Hearth or Mantel Cabinet Mantel and Full Hearth BaseCorner Hearth Base Hardwood Hearth BaseTechnical Service Replacement PartsService Hints Owners Registration Form Tape 107172-01J Warranty Information