Desa EFS33PRA Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

Page 16

16

OPERATING FIREPLACE

For Your Safety Read Before Lighting Lighting Instructions

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in OFF position.

WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clockwise to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 32).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 17.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob counterclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON posi- tion to light burners.

11.Set flame adjustment knob to any level between HI and LO.

WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position.

Ignitor Button

 

 

Flame Adjustment

 

 

Knob

 

 

O

O

L

 

IL T

O

AUTO

P

 

F

N

 

 

 

 

OFF

F

 

 

O

 

 

ON

 

HI

 

 

 

 

Selector Switch

Control Knob

Figure 32 - Control Knob and Ignitor Button Location (Shown as Supplied, No Control Options)

Forvisit..com

107172-01J

Image 16
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationLog Base Assembly VSGF33NRA Shown Product IdentificationProduct Features Local CodesUnpacking AIR for Combustion and VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances Conventional Fireplace InstallationIncluded with Mantel Accessory Assembling and Attaching Optional Brass TrimPlacing Hearth Base Accessory Against Wall BUILT-IN Fireplace Installation Mantel Clearances for Built-In InstallationInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Gas ConnectionPressure Testing Fireplace Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Place front log on top of the grate. Make sure the notches Installing Fireplace Screen Operating Fireplace For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation ON/OFF Series Models Ghrcb and CghrcbOptional Blower Operation Inspecting BurnersPilot Flame Pattern Cleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleMain Burner Front Burner Flame PatternWiring Diagram SpecificationsLogs Models EFS33NR, EFS33NRA, VSGF33NR, and VSGF33NRATroubleshooting Observed Problem Possible Cause RemedyMaintenance, For more Visit www Com Illustrated Parts Breakdown Parts List Not a field replaceable partModels EFS33NR, EFS33NRA, VSGF33NR, VSGF33NRA KEY Part Number Description QTY Accessories Cabinet Mantel and Full Hearth Base Corner Hearth BaseHardwood Hearth Base Laminate Trim for Hearth or MantelService Hints Replacement PartsTechnical Service Owners Registration Form Tape 107172-01J Warranty Information