Inspecting Burners
BURNER FLAME PATTERN
Check flame pattern often. Figure 12 shows correct burner flame pattern.
NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by appliance, causing brief patches of orange flame.
If burner flame pattern is incorrect, as shown in Figure 13
•turn appliance off (see To Turn Off Gas to Appliance
•see Troubleshooting, page 13
Figure 12 - Correct Burner Flame Pattern
Yellow
Tipping
Figure 13 - Incorrect Burner Flame
Pattern
Cleaning and
Maintenance
WARNING: Turn off heater and let cool before cleaning.
CAUTION: You must keep control areas, burner and cir- culating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace and chimney inspected yearly by a qualified service person. Fireplace may needmore frequent cleaningdue to excessive lint from carpeting, bedding material, pet hair, etc.
Specifications
VTD-18NV-JHB
• Rating (Variable): 59,000 Btu/Hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5.0" W.C.
VTD-24NV-JHB
• Rating (Variable): 69,000 Btu/Hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5.0" W.C.
VTD-30NV-JHB
• Rating (Variable): 74,000 Btu/Hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5.0" W.C.
VTD-18PV-JHB
• Rating (Variable): 59,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.
VTD-24PV-JHB
• Rating (Variable): 69,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.
VTD-30PV-JHB
• Rating (Variable): 74,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 10" W.C.
• Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.
*For purpose of input adjustment
12 | www.desatech.com |