Desa VTD-30PV-JHB installation manual What to do if YOU Smell GAS, Ansi Z21.60-2003 CSA

Page 1

VENTED DECORATIVE APPLIANCE

OWNER’S OPERATION AND INSTALLATION MANUAL

ANSI Z21.60-2003

CSA 2.26-2003

APPROVED

MODELS VTD-18NV-JHB, VTD-18PV-JHB, vtd-24nV-jhb,

VTD-24PV-JHB, vtd-30nV-jhb and VTD-30PV-JHB

WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance

CONSUMER: Retain this manual for future reference.

For more information, visit www.desatech.com

Image 1
Contents Ansi Z21.60-2003 CSA What to do if YOU Smell GASSafety Information Table of ContentsSafety Information Switch AssemblyProduct Identification Log SetOptional Accessories Product FeaturesInstallation Local CodesFlue Opening Specifications Installation and ClearancesVenting Specifications for Installation Installing Damper ClampConnecting to GAS Supply Installing Appliance AssemblyInstallation Items Needed Flexible Gas Hose If Allowed by Local Codes Control ValveNatural Gas Test Pressures Equal To or Less Than Psig 3.5 kPa Checking GAS ConnectionsPressure Testing Appliance Gas Connections For Your Safety Read Before LightingOperating Appliance Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureControl Knob Ignitor Shutting Off ApplianceFor purpose of input adjustment Cleaning Maintenance SpecificationsInspecting Burners Burner Flame PatternObserved Problem Possible Cause Remedy TroubleshootingControl Delayed ignition of burner Manifold pressure is too Causing pilot flame to go Out. This problem could beHas been triggered Ignition operationWhite powder residue forming When heated, vapors from Noise when burners are lit Position when burners areTurn control knob to LO Cold Minute Air in gas line Operate burners until air isStatement at top Gas leak. See WarningTechnical Service Service HintsReplacement Parts AccessoriesModels VTD-18NV-JHB, VTD-24NV-JHB, VTD-30Nv-JHB Illustrated Parts BreakdownParts on page 17 of this manual Parts ListKeep this Warranty Warranty InformationLimited Warranty Vented GAS Logs