Removing/Replacing Glass Door

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part informa- tion see Replacement Parts, page 38.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before re- moving glass door or louvers.

Removing Louver Panels

Remove the top and bottom louver panels by si- multaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 36). Repeat for bottom spring latches and pull the lou- vers outward. To install or replace items removed, simply reverse the procedures above.

Spring

Latch

Louver Panel

Figure 36 - Removing Louver Panel

Removing Glass Door

If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.

1.Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the fire- box. Set assembly aside.

2.Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 37).

3.While holding glass door to prevent it from falling and causing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 37).

4.Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket.

5.Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 37).

6.Replace screen/rod assembly by reversing step 1.

7.Replace louvers by reversing procedure under

Removing Louver Panels.

Unlock Lock Latch

Screw

Hinge

Glass

Frame

Assembly

Figure 37 - Removing/Replacing Glass

Door

Cleaning Glass Door

See Cleaning and Maintenance on page 30.

111251-01E

www.desatech.com

23

Image 23
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information High traffic areas Product FeaturesLocal Codes Product IdentificationProper clearances must be maintained Pre-Installation PreparationLocation and space requirements Venting clearances ClearancesFraming and finishing Front Top of Standoffs Vent See ventingBalcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior 32 min Ground Floor InstallationRecommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationNumber Description Desa Venting AccessoriesDesa Elbows Desa TerminationsCheck GAS Type Fireplace InstallationInstalling optional blower accessories Model BK InstallationPlug in blower power cord to duplex outlet Model BKT InstallationInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsRemoving Glass Door Cleaning Glass DoorRemoving/Replacing Glass Door Removing Louver PanelsClose top and bottom louvers Installing logs, lava rock and glowing embersInstalling Log No Open lower louver panel of firebox Optional Remote control Installation model WRCWall Switch Installation Line Wiring DiagramPilot Gas Lighting Instructions For your safety Read before lightingOperating Fireplace Burner Flame Pattern Inspecting BurnersTo Turn OFF GAS To Appliance Optional Remote OperationLogs Cleaning MaintenanceGlass Door Pilot and burnersVenting system Cleaning and MaintenanceTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning Glass soots Flame impingement on logs Tery power is low RemoteImproper log placement Clean out air holes at burnerIllustrated Parts Breakdown Parts List Illustrated Parts Breakdown KEY Description Specifications Replacement PartsService Hints Technical ServiceAccessories Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty