Desa CD32M-2, CD36M-A1, CD36M-A2, CD42M-A2, CD32M-1 Pilot Adjustment, Removing Glass Panel

Page 10

INSTALLATION

Continued

In conformance with local codes, route a 1/2" NPT gas line towards the appliance coming in from either the left or right side of the fireplace (see Figure 13).

Install a sediment trap between the incoming gas line and the gas control box (see Figure 14). The sediment trap should extend down a minimum of 3" (7.62 cm) beyond the center of the pipe.

When routing gas line through conduit sleeve, make sure to repack insulation to fill gaps between gas line and conduit sleeve. Compounds used on threaded joints of gas piping shall be resistant to the action of propane or natural gas. Compounds should be applied lightly to ensure excess sealant does not enter the gas line.

Complete your gas line installation by connect- ing the incoming gas line to the flexible gas line. Secure tightly with a wrench but do not over-tighten.

WARNING: All gas piping and connections must be tested for leaks after the installation is completed.

Never use an open flame to check for a leak. After ensuring that the gas valve is open ap- ply commercial leak detection fluid to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Do not operate any appliance if a leak is detected.

Gas Routing

(Right Side Not Shown)

Side of

Fireplace

Front Face

Figure 13 - Gas Line Routing

Incoming 1/2" Gas Line

 

Permitted By Local Codes

 

Sediment Trap

 

(Not Supplied)

 

3" Min.

 

(7.6 cm)

 

Figure 14 - Sediment Trap

PILOT ADJUSTMENT

 

The pilot or electrode assembly is factory preset

for the proper flame height. Alterations to these

settings may have occurred during shipping and

handling. If this is the case, some minor readjust-

ments may be necessary and should be done by a

qualified service technician. The proper settings

for the thermopile height should be at a distance

of 3/8" (.95 cm) to 1/2" (1.27 cm) from the pilot

flame as shown in Figure 15.

 

1/8"

 

(0.3cm)

3/8" - 1/2"

 

 

(.95cm-1.3cm)

Figure 15 - Pilot Assembly

REMOVING GLASS PANEL

CAUTION: Before you pro- ceed,makesureyourgascontrol valve is in the OFF position.

1.To remove louvers, pull both spring latches (located in each end of louver) toward center of appliance at the same time until disengaged from locating holes. Repeat for bottom end spring latches (see Figure 16, page 11).

2.Remove screen rod by removing rod loop from glass door center bracket. Slide screen rod either to the left or right of fireplace until one end is free to completely remove screen from fireplace.

10

www.desatech.com

111916-01F

Image 10
Contents What to do if YOU Smell GAS CD32MTable of Contents Selecting Location IntroductionBefore YOU Begin Clearances to Combustibles PreparationMantel Clearances Vent Termination Clearances PRE-INSTALLATION PreparationFraming Minimum Clearances for Vent Terminations Venting Installation Precautions InstallationVenting Installation Vertical Termination with Offset and Wall Strap GAS Supply Testing Electrical Hookup and Remote Receiver DiagramGAS Line HOOK-UP Pilot Adjustment Removing Glass PanelInstalling LOG SET Models CD32M and CD36M-A SeriesCD42M-A Decorative Facing Burner Flame AdjustmentFace Extension for Model CD32M only For Your Safety Read Before Lighting Operating Fireplace Operation GuidelinesTo Turn OFF GAS To Appliance Operating FireplaceLighting Instructions Converting PilotConverting Fireplace from Natural GAS to PROPANE/LP GAS Converting Control ValveTroubleshooting Observed Problem Possible Cause RemedyIllustrated Parts Breakdown Models CD32M and CD36M-A SeriesParts List Description QTYModel CD42M-A KEY Part Number Description QTY Specifications Wiring DiagramAccessory and Replacement Parts ValveNot a UPC