INSTALLATION
Continued
In conformance with local codes, route a 1/2" NPT gas line towards the appliance coming in from either the left or right side of the fireplace (see Figure 13).
Install a sediment trap between the incoming gas line and the gas control box (see Figure 14). The sediment trap should extend down a minimum of 3" (7.62 cm) beyond the center of the pipe.
When routing gas line through conduit sleeve, make sure to repack insulation to fill gaps between gas line and conduit sleeve. Compounds used on threaded joints of gas piping shall be resistant to the action of propane or natural gas. Compounds should be applied lightly to ensure excess sealant does not enter the gas line.
Complete your gas line installation by connect- ing the incoming gas line to the flexible gas line. Secure tightly with a wrench but do not
WARNING: All gas piping and connections must be tested for leaks after the installation is completed.
Never use an open flame to check for a leak. After ensuring that the gas valve is open ap- ply commercial leak detection fluid to all gas joints. Bubbles forming show a leak. Correct all leaks at once.
Do not operate any appliance if a leak is detected.
Gas Routing
(Right Side Not Shown)
Side of
Fireplace
Front Face
Figure 13 - Gas Line Routing
Incoming 1/2" Gas Line |
|
Permitted By Local Codes |
|
Sediment Trap |
|
(Not Supplied) |
|
3" Min. |
|
(7.6 cm) |
|
Figure 14 - Sediment Trap | |
PILOT ADJUSTMENT |
|
The pilot or electrode assembly is factory preset | |
for the proper flame height. Alterations to these | |
settings may have occurred during shipping and | |
handling. If this is the case, some minor readjust- | |
ments may be necessary and should be done by a | |
qualified service technician. The proper settings | |
for the thermopile height should be at a distance | |
of 3/8" (.95 cm) to 1/2" (1.27 cm) from the pilot | |
flame as shown in Figure 15. |
|
1/8" |
|
(0.3cm) | 3/8" - 1/2" |
| |
|
Figure 15 - Pilot Assembly
REMOVING GLASS PANEL
CAUTION: Before you pro- ceed,makesureyourgascontrol valve is in the OFF position.
1.To remove louvers, pull both spring latches (located in each end of louver) toward center of appliance at the same time until disengaged from locating holes. Repeat for bottom end spring latches (see Figure 16, page 11).
2.Remove screen rod by removing rod loop from glass door center bracket. Slide screen rod either to the left or right of fireplace until one end is free to completely remove screen from fireplace.
10 | www.desatech.com |