Desa CD36M-A Converting Fireplace from Natural GAS to PROPANE/LP GAS, Converting Control Valve

Page 16

CONVERTING FIREPLACE FROM NATURAL GAS TO PROPANE/LP GAS Continued

6.Locate air shutter at end of burner manifold (end of tube burner for CD42M series). Loosen screw and adjust air shutter to proper setting (see Burner Flame Adjustment, page 13). Retighten screw.

7.Remove pilot hood by pulling up until it disengages from barrel. Do not remove the retainer clip (see Figure 34).

8.Remove pilot orifice from inside barrel using a 5/32" allen wrench to unscrew the orifice.

9.Replace pilot orifice with LP orifice supplied with this kit. The number 30 is stamped on the sleeve for identification. Insert small end of new pilot orifice into barrel and thread until tight with the allen wrench.

10.Line up notch on pilot hood to the positioning tab on barrel receiver and snap back into position.

IMPORTANT: Be careful not to bend or kink the aluminum tubing during conversion. Make sure the pilot hood and orifice are properly mated and aligned after finishing this conversion.

3.Install the identification label enclosed with gas valve regulator to the valve body where it can easily be seen (see Figure 36).

WARNING:Theconversionkit

must be installed by a qualified

service technician in accordance

with the manufacturers instruc-

tions and all applicable codes

andrequirementsoftheauthority

havingjurisdiction.Ifanyinforma-

tionistheseinstructionsisnotfol-

lowed correctly, a fire, explosion

orproductionofcarbonmonoxide

mayresultcausingpropertydam-

age, personal injury or loss of life.

Thequalifiedservicetechnicianis

responsible for the proper instal-

lation of this conversion kit.

Mounting

Pressure

Screws

Regulator

 

Tower

Diaphragm/

 

Pilot Hood Pilot Orifice

Barrel Clip

5/32" Allen Wrench

Pilot Bracket

Spring

Components

OFF

O

Figure 34 - Converting Pilot

CONVERTING CONTROL VALVE

Convert the gas control valve by swapping out the valve regulator portion of the gas valve.

1.Using a TORX T20 or a slotted screwdriver, remove and discard the three mounting screws, pressure regulator tower and dia- phragm/spring components (see Figure 35).

2.Insure that the rubber gasket is properly positioned on the new pressure regulator assembly. Install new pressure regulator as- sembly to valve using new mounting screws supplied with kit. Tighten screws securely (approximately 25 in/lb). See Figure 36.

Figure 35- Removing Parts for Gas Control Valve Conversion

 

Mounting

 

Screws

 

OF

N

F

O

 

 

Rubber

Identification

Gasket

Label

 

Figure 36- Installing New Parts for Gas

Control Valve Conversion

16

www.desatech.com

111916-01F

Image 16
Contents What to do if YOU Smell GAS CD32MTable of Contents Selecting Location IntroductionBefore YOU Begin Clearances to Combustibles PreparationMantel Clearances Vent Termination Clearances PRE-INSTALLATION PreparationFraming Minimum Clearances for Vent Terminations Venting Installation Precautions InstallationVenting Installation Vertical Termination with Offset and Wall Strap GAS Supply Testing Electrical Hookup and Remote Receiver DiagramGAS Line HOOK-UP Pilot Adjustment Removing Glass PanelInstalling LOG SET Models CD32M and CD36M-A SeriesCD42M-A Decorative Facing Burner Flame AdjustmentFace Extension for Model CD32M only For Your Safety Read Before Lighting Operating Fireplace Operation GuidelinesOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Converting PilotConverting Fireplace from Natural GAS to PROPANE/LP GAS Converting Control ValveTroubleshooting Observed Problem Possible Cause RemedyIllustrated Parts Breakdown Models CD32M and CD36M-A SeriesParts List Description QTYModel CD42M-A KEY Part Number Description QTY Specifications Wiring DiagramAccessory and Replacement Parts ValveNot a UPC