Troubleshooting

6.4.4Motor hunts

(1) Speed control

The motor hunts.

Is the speed setting varying?

N

PLG has not been set.

N

Is the speed gain too high compared to the machine?

N

Y

Take proper action to stabilize the speed setting.

(Example: Enter the filter time constant (Pr. 822) to the analog terminal.)

Y

Perform PLG setting

(Refer to page 12 for details.)

Y

Perform easy gain tuning (Pr. 819 = 1 (load estimation, gain estimation), 2

(gain estimation)).

However, gain estimation and load estimation may not be made well depending on the machine and operational specifications.

(For details, refer to page 43.)

Is there load variation?

N

Y

Choose model adaptive speed control. (Pr. 877) <Refer to the Instruction Manual (detailed).> Alternatively, if load variation is large, the motor speed also varies. Increasing the response of speed control decreases speed variation.

 

Is torque restriction

 

Y

 

being made?

 

 

 

 

 

 

 

 

 

 

 

 

Increase the torque restriction

 

N

 

level.

 

 

 

 

Lighten the load.

Please contact your sales

 

representative.

 

87

Page 91
Image 91