Mitsubishi Electronics FR-V500 Droop gain, Droop filter constant, Droop function 288, Orientation

Models: FR-V500

1 112
Download 112 pages 3.61 Kb
Page 67
Image 67

PARAMETERS

Function list (Extended function parameters)

 

 

 

 

 

 

 

At-a-glance Guide to Func-

 

 

 

 

 

 

 

 

tions

 

 

 

 

 

 

 

 

": Usable function

Function

Parameter

 

 

 

Cus-

×: Unusable function

 

 

 

 

 

 

* : Functions that can be used

 

 

 

Name

Outline

Factory

tomer

 

 

 

for param eter-set position con-

 

 

 

Setting

Set-

 

 

 

 

 

 

trol

 

 

 

 

 

 

 

ting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vector Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

Torque

Position

 

 

 

 

 

 

 

control

control

control

 

 

 

 

 

 

 

 

 

 

 

 

286

Droop gain

Set when providing a drooping characteristic for the speed in proportion to the load

0%

 

"

×

×

 

 

 

 

torque.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Droop

287

Droop filter constant

0 to 100% (Pr. 286)

0.3s

 

"

×

×

0.00 to 1.00s (Pr. 287)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Without droop operation during acceleration/deceleration,

 

 

 

 

 

 

 

 

Droop function

 

 

 

 

 

 

 

288

1: Without droop operation during acceleration/deceleration

0

 

"

×

×

 

 

activation selection

 

 

 

(Pr. 288)

 

 

 

 

 

 

 

 

 

 

Additional function

342

E2PROM write

0:E2PROM

0

 

"

"

"

 

 

 

presence/absence

1:RAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For the stop position command, either the internal stop position command or the

 

 

 

 

 

 

 

 

 

external stop position command using external signals may be selected.

 

 

 

 

 

 

 

350

Stop position

0:Internal stop position command

 

 

"

×

×

 

 

1:External stop position command (6 bit data when the FR-V5AX is fitted )

9999

 

 

 

 

command selection

2:External stop position command (12 bit data when the FR-A5AX is fitted )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3:External stop position command (16 bit data when the FR-V5AH is fitted )

 

 

 

 

 

 

 

 

 

9999:Orientation control invalid

 

 

 

 

 

 

 

351

Orientation

Decrease the motor speed to the set value during the orientation command is valid.

200r/min

 

"

×

×

 

 

 

switchover speed

0 to 1000r/min

 

 

 

 

 

 

 

356

Internal stop position

When "0" is set in Pr. 350 "stop position command selection", the internal position

 

 

"

×

×

 

 

command is activated and the setting value of Pr. 356 becomes a stop position.

0

 

Orientation

 

command

0 to 16383

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

357

In-position zone

Set the in-position zone at a stop of the orientation.

11

 

"

×

×

 

 

0 to 8192

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When "1" is set in Pr. 350 "stop position command selection", the external position

 

 

 

 

 

 

 

 

External position

command is activated and the setting value of Pr. 360 becomes a stop position.

 

 

 

 

 

 

 

360

0: External position command invalid

0

 

"

×

×

 

 

 

command selection

1: 4096 per rotation with the FR-A5AX, 64 per rotation with the FR-V5AX

 

 

 

 

 

 

 

 

 

2 to 127: The external stop position command may be used to set up to 128 stop

 

 

 

 

 

 

 

 

 

positions at regular intervals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

361

Position shift

The stop position is a position obtained by adding the setting value of Pr. 361 to the

 

 

"

×

×

 

 

position command. You can make fine adjustments to a stop position.

0

 

 

 

 

 

0 to 16383

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

362

Orientation position

Adjust at a stop of the orientation

10

 

"

×

×

 

 

 

loop gain

0.1 to 100

 

 

 

 

 

Controlsystem function

374

Overspeed detection

Overspeed occurs if the motor speed exceeds the preset speed.

3450

 

"

"

"

 

 

 

level

0 to 4200r/min

r/m in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

380

Acceleration

 

0%

 

"

"

×

 

 

 

S-pattern 1

 

 

 

 

 

 

C

381

Deceleration

You can set X20 in any of Pr. 180 to 183 and Pr. 187, and set an S pattern by turning it

0%

 

"

"

×

pattern-S

 

S-pattern 1

 

 

on/off.

 

 

382

S-pattern 2

0 to 50%

0%

 

"

"

×

 

 

 

Acceleration

Set an S pattern in Pr. 380 to Pr. 383.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

383

Deceleration

 

0%

 

"

"

×

 

 

 

S-pattern 2

 

 

 

 

 

 

 

 

393

Orientation selection

0,1,2,10,11,12

0

 

"

×

×

 

 

 

 

 

 

 

 

 

 

 

 

396

Orientation speed

0 to 1000

60

 

"

×

×

Orientation

 

 

gain (P term)

 

 

 

 

 

 

 

398

Orientation speed

0 to 100.0%

1

 

"

×

×

 

 

397

Orientation speed

0 to 20.0s

0.333

 

"

×

×

 

 

 

integral time

 

 

 

 

 

 

 

 

 

gain (D term)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

399

Orientation

0 to 1000

20

 

"

×

×

 

 

 

deceleration ratio

 

 

 

 

 

 

63

Page 67
Image 67
Mitsubishi Electronics FR-V500 Droop gain, Droop filter constant, Droop function 288, Activation selection, Stop position