Mitsubishi Electronics FR-V500 Refer to page 43 for details, Pr control system selection

Models: FR-V500

1 112
Download 112 pages 3.61 Kb
Page 57
Image 57

Function list (Simple mode parameters)

Pr. 160 "extended function display selection"

!Set this parameter to display/set the extended function parameters.

Setting

Description

 

 

0

Only the simple mode parameters are displayed.

 

 

1

All parameters are displayed.

 

 

REMARKS

Refer to page 54 for the parameters (extended function parameters) available when "1" is set in Pr. 160 "extended function dis- play selection".

Pr. 800 "control system selection"

Select the inverter control system such as speed control, torque control or position control.

Setting

Drive System

Control Method

Remarks

0

 

Speed control

Factory setting

(factory setting)

 

 

 

 

1

 

Torque control

2

 

Speed control-torque control

MC ON: Torque control

 

switchover

MC OFF: Speed control

 

PLG vector control

3

Position control

 

4

 

Speed control-position control

MC ON: Position control

 

switchover

MC OFF: Speed control

 

 

5

 

Position control-torque control

MC ON: Torque control

 

switchover

MC OFF: Position control

 

 

20

V/F control

Speed control

Related parameters

M C signal term inal assignm ent Set "26" in any of Pr. 180 to Pr. 183 and Pr. 187 (input term inal function selection). (Refer to page 61.)

REMARKS

Set the control system selection of the second motor in Pr. 451 "second motor control method selection". Refer to the Instruc- tion Manual (detailed) for details.

Pr. 818 "easy gain tuning response level setting", Pr. 819 "easy gain tuning"

Refer to page 43 for details.

53