Mitsubishi Electronics FR-V500 instruction manual At-a-glance guide to motor setting

Models: FR-V500

1 112
Download 112 pages 3.61 Kb
Page 24
Image 24

Setting the motor

REMARKS

When using a conventional motor (SF-VR, SF-JR) or other motors, refer to the Instruction Manual (detailed).

<At-a-glance guide to motor setting>

 

 

 

 

Dedicated Motor

 

Standard Motor

 

Constant-torque Motor

 

 

 

Description

 

 

(with PLG)

 

 

 

Parameter,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mitsubishi

 

Mitsubishi

 

 

Mitsubishi

 

 

 

Jumper Con-

 

 

Other

 

No.

Item

necter, Ter-

SF-V5R

 

SF-JR (with PLG)

 

 

manufac-

SF-HRCA

SF-JRCA

Other

 

 

 

 

 

SF-HR

Others

manufac-

 

 

minal

1500r/min

SF-VR

(2, 4, 6P)-

(4P)-

turer

(4P) (with

(with

 

 

 

2.2kW to

1.5kW or

(with PLG)

(with PLG)

turer

 

 

 

 

series

 

(with PLG)

PLG)

PLG)

 

 

 

 

 

 

 

55kW

less

 

 

 

 

 

 

1

Motor

Pr. 71 setting

 

30

30

0

20

3 to 8

3 to 8

3 to 8

10

13 to 18

13 to 18

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Offline

 

 

Not

Not

Not

Not

Required

Required

Required

Not

Required

Required

tuning

 

 

required *

required *

required *

required *

required *

 

 

 

1 :1

INV

INV

INV

INV

INV

INV

INV

INV

INV

INV

 

Capacity

 

capacity

capacity

capacity

capacity

capacity

capacity

capacity

capacity

capacity

capacity

3

Pr. 80 setting

 

setting

1 rank

Motor

Motor

Motor

Motor

Motor

Motor

Motor

Motor

Motor

Motor

 

 

 

 

 

lower

capacity

capacity

capacity

capacity

capacity

capacity

capacity

capacity

capacity

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

4

of PLG

Pr. 851setting

 

2048

1000

1024

1024

1024

-

-

1024

1024

-

 

pulses

 

 

 

 

 

 

 

 

 

 

 

 

 

PLG

 

 

 

 

 

 

 

 

 

 

 

 

5

rotation

Pr. 852 setting

 

1

1

1

1

1

-

-

1

1

-

 

direction

 

 

 

 

 

 

 

 

 

 

 

 

 

PLG

 

Power

 

 

 

 

 

 

 

 

 

 

 

power

 

 

 

 

 

 

 

 

 

 

 

 

 

supply

 

 

 

 

 

 

 

 

 

 

6

supply

PLG

12V

5V

5V

5V

5V

-

-

5V

5V

-

specifi-

 

specifi-

power supply

 

 

 

 

 

 

 

 

 

 

 

cation

 

 

 

 

 

 

 

 

 

 

 

cation

jumper con-

 

 

 

 

 

 

 

 

 

 

 

 

 

necter on the

Output

Compli-

Differential

Differential

Differential

Differential

-

-

Differential

Differen-

-

 

PLG

back of the

circuit

mentary

 

 

 

 

 

 

 

tial

 

 

control termi-

Termi-

 

 

 

 

 

 

 

 

 

 

7

output

 

 

 

 

 

 

 

 

 

 

nal

nating

 

 

 

 

 

 

 

 

 

 

 

type

No

Yes

Yes

Yes

Yes

-

-

Yes

Yes

-

 

 

 

 

resis-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tance

 

 

 

 

 

 

 

 

 

 

 

Elec-

 

 

 

 

Rated

Rated

Rated

 

 

Rated

Rated

 

 

tronic

 

 

 

 

 

 

 

8

Pr. 9 setting

 

0

0

inverter

inverter

inverter

-

-

inverter

inverter

-

thermal

 

 

 

 

 

 

current

current

current

 

 

current

current

 

 

relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermal

Across

 

Connect to

Connect to

Open

Open

Open

-

-

Open

Open

-

9

protector

OH-SD

 

the thermal

the thermal

 

 

 

 

 

 

 

 

 

 

input

Pr. 876 setting

 

1

1

0

0

0

-

-

0

0

-

 

 

 

 

 

 

0 or 1

0 or 1

0 or 1

0 or 1

0 or 1

0 or 1

0 or 1

0 or 1

 

Torque

 

 

 

 

(Selec-

10

Pr. 801 setting

 

1

1

(Selection

(Selection

(Selection

(Selection

(Selection

(Selection

(Selection

charac-

 

is

is

is

is

is

is

tion

is

 

teristic

 

 

 

 

is

 

 

 

 

 

required)

required)

required)

required)

required)

required)

required)

 

 

 

 

 

 

required)

CAUTION

1.Set number of motor poles in Pr.81.

2.For -, make setting according to the motor used.

3.The half-tone screened cells are factory set.

4.Check the power supply specification of PLG and change a jumper connecter.

5.*:Perform offline auto tuning (mode without rotation) for the wiring length to be reflected on the con- trol when the wiring length is long (30m or longer as reference).)

<When using other manufacturers’ motors>

offline auto tuning (rotation mode) is necessary. Perform offline auto tuning with the motor alone before connecting a load. If higher torque accuracy is required, perform online auto tuning next.

Offline auto tuning

The inverter measures necessary motor circuit constant and stores it to improve low speed torque.

Online auto tuning

High torque accuracy corresponding to the motor temperature variation is available.

2

INSTALLATION AND WIRING

20

Page 24
Image 24
Mitsubishi Electronics FR-V500 At-a-glance guide to motor setting, When using other manufacturers’ motors