PARAMETERS

Function list (Extended function parameters)

 

 

 

 

 

 

At-a-glance Guide to Func-

 

 

 

 

 

 

 

tions

 

 

 

 

 

 

 

": Usable function

Function

Parameter

 

 

 

Cus-

×: Unusable function

 

 

 

 

 

* : Functions that can be used

 

 

Name

Outline

Factory

tomer

 

 

for param eter-set position con-

 

 

Setting

Set-

 

 

 

 

 

trol

 

 

 

 

 

 

ting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vector Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

Torque

Position

 

 

 

 

 

 

control

control

control

 

 

 

 

 

 

 

 

 

 

 

 

Determines the frequency changing pattern for acceleration/deceleration.

 

 

 

 

 

 

 

Acceleration/

0: Linear acceleration/deceleration

 

 

 

 

 

 

29

1: S-pattern acceleration/deceleration A

0

 

"

"

×

 

 

deceleration pattern

2: S-pattern acceleration/deceleration B

 

 

 

 

 

 

 

 

3: Backlash compensation acceleration/deceleration

 

 

 

 

 

functions

 

 

4: S-pattern acceleration/deceleration C

 

 

 

 

 

 

 

 

 

 

 

 

 

30

function selection

1: Brake resistor (FR-ABR)

0

 

"

"

"

 

 

Regenerative

Set when using the FR-ABR, FR-HC or FR-CV option for frequent start/stop operation.

 

 

 

 

 

selection

 

0: Internal brake resistor, brake unit

 

 

 

 

 

 

 

2: High power factor converter (FR-HC), power return common converter (FR-CV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

Speed jump 1A

 

9999

 

"

"

×

 

 

 

 

 

 

 

 

 

Operation

32

Speed jump 1B

 

9999

 

"

"

×

 

 

0 to 3600r/min, 9999

 

 

 

 

 

34

Speed jump 2B

9999

 

"

"

×

 

33

Speed jump 2A

Set the speed ranges you want to avoid during constant-speed operation to avoid

9999

 

"

"

×

 

 

 

resonance with the machine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35

Speed jump 3A

 

9999

 

"

"

×

 

 

 

 

 

 

 

 

 

 

36

Speed jump 3B

 

9999

 

"

"

×

 

 

 

 

 

 

 

 

 

 

37

Speed display

You can set the speed as a machine speed.

0

 

"

"

"

 

0, 1 to 9998

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

Up-to-speed

You can adjust the output signal on/off range when the output speed reaches the

 

 

"

×

×

Outputterminal functions

running speed.

10%

 

43

Speed detection for

transfer and other applications.

9999

 

"

"

"

 

 

sensitivity

0 to 100%

 

 

 

 

 

 

42

Speed detection

You can adjust the speed detected.

300r/min

 

"

"

"

 

0 to 3600r/min

 

 

 

 

 

 

 

 

 

 

 

 

You can change the speed detection level for forward or reverse rotation in vertical lift,

 

 

 

 

 

 

 

reverse rotation

0 to 3600r/min, 9999

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

functions

44

Second acceleration/

Second function of the acceleration/deceleration time set in Pr. 7, Pr. 8.

5s

 

"

"

× *

 

 

deceleration time

0 to 3600s/0 to 360s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Second

45

Second deceleration

Second function of the deceleration time set in Pr. 8.

9999

 

"

"

× *

 

 

time

0 to 3600s/0 to 360s, 9999

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outputterminal functions

50

Second speed

Set the speed at which the FB2 signal is output.

750r/min

 

"

"

"

 

 

detection

0 to 3600r/min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You can select the DU/PU main display data.

 

 

 

 

 

 

 

 

0, 100: Speed, output current, output voltage, alarm display

 

 

 

 

 

 

 

 

5: Preset speed

 

 

 

 

 

 

 

 

6: Output frequency

 

 

 

 

 

 

 

 

7: Motor torque

 

 

 

 

 

 

 

 

8: Converter output voltage

 

 

 

 

 

 

 

 

9: Regenerative brake duty

 

 

 

 

 

 

 

 

10: Electronic thermal relay load factor

 

 

 

 

 

 

 

 

11: Output current peak value

 

 

 

 

 

 

52

DU/PU main display

12: Converter output voltage peak value

 

 

"

"

"

 

17: Load meter

0

 

 

 

data selection

18: Motor exciting current

 

 

 

 

 

 

 

 

19: Position pulse

 

 

 

 

 

 

 

 

20: Cumulative energization time

 

 

 

 

 

functions

 

 

23: Actual operation time

 

 

 

 

 

 

 

24: Motor load factor

 

 

 

 

 

 

 

 

32: Torque command

 

 

 

 

 

 

 

 

33: Torque current command

 

 

 

 

 

Display

 

 

34: Motor output

 

 

 

 

 

 

 

35: Feedback pulse

 

 

 

 

 

 

 

 

38: Trace status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You can select the PU level display data.

 

 

 

 

 

 

 

 

0: No monitor

 

 

 

 

 

 

 

 

1: Speed

 

 

 

 

 

 

 

 

2: Output current

 

 

 

 

 

 

 

 

3: Output voltage

 

 

 

 

 

 

 

 

5: Preset speed

 

 

 

 

 

 

53

PU level display data

6: Output frequency

1

 

"

"

"

 

selection

7: Motor torque

 

 

 

8: Converter output voltage

 

 

 

 

 

 

 

 

9: Regenerative brake duty

 

 

 

 

 

 

 

 

10: Electronic thermal relay load factor

 

 

 

 

 

 

 

 

11: Output current peak value

 

 

 

 

 

 

 

 

12: Converter output voltage peak value

 

 

 

 

 

 

 

 

17: Load meter

 

 

 

 

 

 

 

 

18: Motor exciting current

 

 

 

 

 

55

Page 59
Image 59
Mitsubishi Electronics FR-V500 Deceleration pattern, Regenerative, Speed jump 1A, Speed jump 1B, Speed jump 2B, Time