Connection diagram, PLG cable, PU connector

(2)Setting the number of PLG pulses and PLG rotation direction Set the following parameters according to the PLG specification.

Parameter

Name

Factory Setting

Setting Range

Remarks

 

 

 

 

 

851

Number of PLG pulses

2048

0 to 4096

Extension

852

PLG rotation direction

1

0, 1

mode

 

 

 

 

 

!The rotation direction monitor of the parameter unit displays the rotation direction of the encoder, refer to the following table.

Pr. 852 Setting

Relationship between the motor and PLG

 

 

 

 

 

CW

0

 

 

 

 

A

 

 

 

 

 

 

PLG

 

1

Forward rotation is clockwise rotation when viewed from A.

CCW

A

PLG

(factory setting)

Forward rotation is counterclockwise rotation when viewed from A.

REMARKS

By setting "1" in Pr.160 "extended function selection", Pr. 851 and Pr. 852 are made valid.

The number of PLG pulses should be between 1000 and 4096.

!When using a conventional motor and a PLG cable (FR-VCBL/FR-JCBL), refer to the Instruction Manual (detailed).

13

Page 17
Image 17
Mitsubishi Electronics FR-V500 instruction manual Parameter Name Factory Setting Setting Range Remarks