Common specifications

7.2

 

Common specifications

 

 

 

 

 

 

 

 

 

 

 

specifications

 

Control system

Soft-PWM control or high carrier frequency sine-wave PWM control can be selected.

 

 

Vector control, or V/F control can be selected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control mode

 

Speed control, torque control, position control

 

 

 

 

Speed setting

 

Analog input

0.03% of the maximum set speed

 

 

 

 

 

resolution

 

Digital input

0.003% to the maximum setting (minimum setting 0.1r/min)

 

 

 

 

Acceleration/deceleration time

0 to 3600 s (0.1 s increments)

 

 

 

Control

 

Acceleration/deceleration

Linear, S pattern (3 types) or backlash compensation acceleration/deceleration can be selected.

 

 

pattern

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Torque restriction level

Torque restriction value can be set (0 to 400% variable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal

 

Setting Range

Speed Control

Torque Control

 

 

 

 

 

 

 

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

0 to 10V (resolution 0.03%)

Main speed setting

Speed restriction

 

 

 

Analog setting signal

 

 

 

 

Speed restriction compensation/

 

 

 

 

 

0 to ±10V

Auxiliary speed setting/m agnetic flux

magnetic flux command/forward/

 

 

 

 

 

 

 

1

 

reverse rotation speed restriction

 

 

 

 

 

 

 

 

(resolution 0.05% )

com m and/regenerative torque restriction

 

 

 

 

 

 

 

 

 

(analog polarity switchover speed

 

signals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

restriction)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

0 to ±10V (resolution 0 .05% )

Torque restriction/Torque bias

Torque command

 

 

 

 

Option (FR-V5AX)

 

 

0 to ±10V

M ain speed setting (at this tim e,

Speed restriction (at this time, terminal

 

Input

 

 

6

 

2 is invalid)/Torque command (at this

 

 

 

 

(resolution 0.003% )

term inal 2 is invalid)/torque restriction

 

 

 

 

 

 

 

 

time, terminal 3 is invalid)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 fixed

function terminals

Forward rotation com m and, alarm reset, external therm al relay

 

 

 

Contact signal

 

5 function terminals

Selection can be made from reverse rotation command, multi-speed setting (max. 15

 

 

 

 

 

 

 

speeds), remote setting, jog operation (Caution 1), second function selection, third

 

 

 

 

 

 

 

 

 

 

function selection, output stop, start signal self-holding, pre-excitation, control mode

 

 

 

 

 

 

 

 

 

 

switchover, torque restriction selection, S pattern switchover, PID control terminal,

 

 

 

 

Option (FR-V5AX)

6 multi-function terminals

orientation command, break opening completion signal, PU operation/external operation

 

 

 

 

switchover, torque bias selection 1, torque bias selection 2, P control selection, servo on,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HC connection, and PU/external interlock.

 

 

 

 

Contact signal

 

1 changeover contact

Selection can be made from inverter running, inverter running 2, up to speed,

 

 

 

 

(230VAC 0.3A, 30VDC 0.3A)

instantaneous power failure (undervoltage), speed detection, second speed

 

 

 

 

 

 

 

 

 

 

Open collector signal

3 multi-function terminals

detection, third speed detection, PU operation mode, overload alarm,

 

 

 

 

 

 

 

 

 

 

regenerative brake prealarm, electronic thermal relay prealarm, output current

 

 

 

 

Option (FR-V5AY)

3 multi-function terminals

 

 

 

 

detection, zero current detection, PID lower limit, PID upper limit, PID forward/

 

 

 

 

Option (FR-V5AM)

1 multi-function terminal

Inverter

 

 

 

reverse rotation output, operation ready, operation ready 2, brake opening

signals

 

 

 

 

 

 

 

 

request, fan fault output, heatsink overheat prealarm, orientation in-position,

 

 

 

 

Option (FR-A5AY))

7 multi-function terminals

forward rotation output, reverse rotation output, low speed output, torque

 

 

 

 

detection, regenerative status output, minor fault output, minor fault output

 

Output

 

 

 

 

 

 

 

 

2,alarm output, maintenance timer output, remote output, output speed

 

 

 

 

 

 

 

 

 

detection, second (third) output speed detection, in-position and trace status.

 

 

Analog output

 

0 to ±10V 12 bits ×1CH

Selection can be made from speed, output current, output voltage, preset

 

 

 

0 to 10V 12 bits ×1CH

speed, output frequency, motor torque, converter output voltage, regenerative

 

 

 

 

 

 

 

 

 

 

brake duty, electronic overcurrent protection load factor, output current peak

 

 

 

 

Option (FR-A5AY)

0 to 10V 10 bits × 1CH

value, converter output voltage peak value, load meter, motor exciting current,

 

 

 

 

0 to 20mA 10 bits × 1CH

motor output, reference voltage output, torque command, torque current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

command and torque monitoring.

 

 

 

 

PLG

pulse output

A phase, B phase, Z phase (A and

B phases can be divided)

 

 

 

 

option (FR-V5AY)

Open collector/differential line driver.

 

 

 

 

 

 

 

 

Maximum/minimum speed setting, speed jump, external thermal relay input selection, polarity reversible operation,

 

 

 

 

 

 

 

override function, automatic restart operation after instantaneous power failure, forward/reverse rotation

 

Operational functions

prevention, operation mode selection, offline auto tuning function, online auto tuning function, easy gain tuning,

 

computer link operation, remote setting, brake sequence, second function, third function, multi-speed operation,

 

 

 

 

 

 

 

coasting to stop, power failure stop, PID control, speed feed forward, model adaptive speed control, master/slave,

 

 

 

 

 

 

 

torque bias, 12-bit digital command (FR-A5AX option), 16-bit digital command (FR-A5AH option), pulse train input

 

 

 

 

 

 

 

(FR-A5AP option), motor thermistor interface (FR-V5AX option)

 

 

 

 

 

 

 

 

Selection can be made from speed, output current, output voltage, preset speed, output frequency, motor torque,

 

Display

 

Parameter unit

converter output voltage, regenerative brake duty, electronic overcurrent protection load factor, output current

 

 

peak value, converter output voltage peak value, input terminal status (Caution 4), output terminal status (Caution

 

 

(FR-DU04-1/FR-PU04V)

 

 

 

4), load meter, motor exciting current, position pulse, cumulative operation time, actual operation time, motor load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

factor, torque command, torque current command, feedback pulse, motor output, trace status.

 

 

 

Alarm definition

Alarm definition is displayed when protective function is activated. 8 past alarm definitions are stored. (Only 4

 

 

 

alarm definitions are displayed on the operation panel.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overcurrent shut-off (acceleration, deceleration, constant speed), regenerative overvoltage shut-off (acceleration, deceleration,

 

 

 

 

 

 

 

constant speed), undervoltage, instantaneous power failure, overload shut-off (electronic thermal relay), brake transistor alarm

 

Protective functions

(Caution 2), earth (ground) fault current, power output short circuit (12/24VDC/operation panel), stall prevention, external

 

thermal relay, heatsink overheat, fan fault, option alarm, parameter error, PU disconnection, encoder no-signal, speed deviation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

large, overspeed, position error large, CPU error, encoder phase error, output phase failure, retry count excess, brake sequence

 

 

 

 

 

 

 

error

 

 

 

 

ent

 

Ambient temperature

-10C to +50°C(non-freezing)

 

 

 

 

Ambient humidity

90%RH or less (non-condensing)

 

 

 

nvironmE

 

 

 

 

 

Altitude, vibration

Maximum 1,000m above sea level, 5.9m/s2 or less (compliant with JIS C 0040)

 

 

 

Storage tem perature (C aution 3)

-20 to +65°C

 

 

 

 

 

Atmosphere

 

Indoor use. (No corrosive gas, flammable gas, oil mist, dust and dirt)

 

 

 

 

 

 

 

 

 

 

 

 

 

Dedicated motor

Ambient temperature, humidity

-10 to +40°C (non-freezing), 90%RH or less (non-condensing)

 

Insulation

 

Class F

 

 

 

Structure

 

Totally enclosed forced draft system

 

 

Detector

 

PLG 2048P/R, A phase, B phase, Z phase +12VDC power supply

 

 

Equipment

 

PLG, thermal protector, fan

 

 

 

 

 

 

 

 

 

 

Vibration rank

 

V10

 

 

 

Dedicated cablePLG

Resolution

 

2048 pulse/rev

 

 

Power supply voltage

12VDC±10%

 

 

 

 

 

 

Current consumption

90mA

 

 

 

 

Output signal form

 

A, B phases (90° phase shift) Z phase: 1 pulse/rev

 

 

Output circuit

 

Complimentary (constant voltage output matched by emitter follow)

 

 

Output voltage

 

"H" level: Power supply voltage 9V or more (IOH: -20mA), "L" level: Power supply voltage 3V or less (IOL: 20mA)

CAUTION

1.Jog operation may also be performed from the operation panel (FR-DU04-1) or the parameter unit (FR- PU04V).

2.Not provided for the FR-V520-18.5K to 55K, FR-V540-18.5K to 55K that do not have a built-in brake circuit.

3.Temperature applicable for a short period in transit, etc.

4.Not provided for the operation panel (FR-DU04-1).

101

Page 105
Image 105
Mitsubishi Electronics FR-V500 instruction manual Common specifications