Mitsubishi Electronics FR-V500 Setting the PLG, PLG output circuit jumper connector

Models: FR-V500

1 112
Download 112 pages 3.61 Kb
Page 16
Image 16

Connection diagram, PLG cable, PU connector

2.2.3PLG connection cable (FR-V5CBL)

When using a dedicated motor (SF-V5R series), use a PLG cable (FR-V5CBL) for connection.

Inverter side

PLG side

 

 

 

 

 

connector

MS3057-12A

 

F-DPEVSB 12P0.2mm2

 

 

 

 

Earth (Ground) wire

 

 

 

 

 

 

 

 

 

 

60

11

 

 

 

 

 

 

 

MS3106B20-29S

(Unit: mm )

 

 

 

 

 

 

 

L

 

 

FR-V500

PLG (SF-V5R)

PA

A

PAR

B

PB

C

PBR

D

PZ

F

PZR

G

PG

S

SD

R

2mm2

Inverter earth (ground) terminal

Type

Length L (m)

Remarks

FR-V5CBL5

 

5

 

 

FR-V5CBL15

 

15

 

Standard product

FR-V5CBL30

 

30

 

 

Contact us separately for other lengths.

 

 

 

Positioning keyway

 

M

A

B

C

 

 

N

 

 

 

L

 

P

D

 

 

T

 

 

 

 

 

 

 

K

 

 

E

 

 

S

 

R

 

 

 

 

 

 

J

 

F

 

 

 

H

 

 

 

G

 

 

MS3106B20-29S

(As viewed from wiring side)

2.2.4Setting the PLG

When a dedicated PLG cable (FR-V5CBL) is used, a setting change may not be required.

CAUTION

Make setting correctly.

Fitting the jumper connector to the position exceeding the power specification results in a PLG failure. Fitting the jumper connector to the position below the power specification results in a PLG malfunction.

(1)Setting the power supply specification of the PLG and pulse output type

Switch the position of the jumper connector on the back surface of the control circuit terminal block according to the PLG specification. (Refer to page 16 for removal and installation of the control circuit terminal block.)

2

WIRING

CAUTION

PLG power supply jumper connector

The connector is fitted to 12V at factory shipment. Switch its position according to power supply specification.

REMARKS

Since the specification of the PLG of the conventional motors (SF-VR, SF- JR with PLG) is 5V, fit the jumper con- nector to 5V.

!PLG output circuit jumper connector

The connector is fitted to complimentary at factory shipment. Switch its position according to output circuit.

 

 

Power supply voltage is 5.5V

 

 

Power supply voltage is 12V

 

 

Power supply voltage is 24V

 

 

Power supply voltage is external

 

 

 

 

 

 

Complimentary (CMP)

 

 

 

 

 

 

Differential line driver (LDV)

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminating resistance

 

 

 

 

 

 

Terminating resistance

 

 

 

INSTALLATION AND

12

Page 16
Image 16
Mitsubishi Electronics FR-V500 instruction manual Setting the PLG, PLG output circuit jumper connector, Type Length L m