PARAMETERS

Function list (Extended function parameters)

 

 

 

 

 

 

At-a-glance Guide to Func-

 

 

 

 

 

 

 

tions

 

 

 

 

 

 

 

": Usable function

Function

Parameter

 

 

 

Cus-

×: Unusable function

 

 

 

 

 

* : Functions that can be used

 

 

Name

Outline

Factory

tomer

 

 

for param eter-set position con-

 

 

Setting

Set-

 

 

 

 

 

trol

 

 

 

 

 

 

ting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vector Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

Torque

Position

 

 

 

 

 

 

control

control

control

 

 

 

 

 

 

 

 

 

 

812

Torque restriction

0 to 400%, 9999

9999

 

"

×

"

 

 

level (regeneration)

 

 

 

 

 

 

 

813

Torque restriction

0 to 400%, 9999

9999

 

"

×

"

 

 

level (3 quadrant)

 

 

 

 

 

 

 

814

Torque restriction

0 to 400%, 9999

9999

 

"

×

"

 

 

level (4 quadrant)

 

 

 

 

 

 

 

815

Torque restriction

Second function of the torque restriction level. Made valid when the RT terminal is on.

9999

 

"

×

"

 

 

level 2

0 to 400%, 9999

 

 

 

 

 

 

816

Acceleration torque

Set the torque restriction value during acceleration.

9999

 

"

×

"

 

 

restriction

0 to 400%, 9999

 

 

 

 

 

 

817

Deceleration torque

Set the torque restriction value during deceleration.

9999

 

"

×

"

 

 

restriction

0 to 400%, 9999

 

 

 

 

 

functions

818

Easy gain tuning

1 to 15

2

 

"

×

"

 

response level setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

819

Easy gain tuning

0,1,2

0

 

"

×

"

system

selection

 

 

 

 

 

 

 

 

 

820

Speed control P gain

in response to a speed command change and reduces speed variation with

60%

 

"

×

"

Control

 

 

Set the proportional gain for speed control. (Increasing the value improves trackability

 

 

 

 

 

 

1

disturbance.)

 

 

 

 

 

 

 

 

0 to 1000%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

821

Speed control

Set the integral time during speed control. (Decrease the value to shorten the time

 

 

"

×

"

 

taken for returning to the original speed if speed variation with disturbance occurs.)

0.333s

 

 

 

integral time 1

0 to 20s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

822

Speed setting filter 1

Set the primary delay filter for the analog voltage-based speed setting.

0s

 

"

"

×

 

0 to 5s

 

 

 

 

 

 

 

 

 

 

823

Speed detection filter

Set the primary delay filter for the speed feedback.

0.001s

 

"

"

"

 

 

1

0 to 5s

 

 

 

 

 

 

 

Torque control P gain

Set the proportional gain for the current control of the q and d axes. (Increasing the

 

 

 

 

 

 

824

value improves trackability in response to a current command change and reduces

100%

 

"

"

"

 

 

1

current variation with disturbance.)

 

 

 

 

 

 

 

 

0 to 200%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Torque control

Set the integral time for the current control of the q and d axes. (Decreasing the value

 

 

 

 

 

 

825

shortens the time taken to return to the original torque if current variation with

5ms

 

"

"

"

 

 

integral time 1

disturbance occurs.)

 

 

 

 

 

 

 

 

0 to 500ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set the primary delay filter for the analog voltage (No. 3 terminal)-based torque

 

 

 

 

 

functions

826

Torque setting filter 1

command value. (Also valid for the torque restriction from the No. 3 terminal during

0s

 

"

"

"

 

 

speed control.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 5s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system

827

Torque detection filter

Set the primary delay filter for the current feedback.

0s

 

"

"

"

 

1

0 to 5s

 

 

 

 

 

 

 

 

 

 

 

 

Control

828

Model speed control

0 to 1000%

60%

 

"

×

"

 

Speed control P gain

Second function of Pr. 820 (valid when RT terminal is on)

 

 

 

 

 

 

 

gain

 

 

 

 

 

 

 

830

2

0 to 1000%, 9999

9999

 

"

×

"

 

 

 

 

 

 

 

 

 

 

831

Speed control

Second function of Pr. 821 (valid when RT terminal is on)

9999

 

"

×

"

 

 

integral time 2

0 to 20s, 9999

 

 

 

 

 

 

832

Speed setting filter 2

Second function of Pr. 822 (valid when RT terminal is on)

9999

 

"

"

×

functions

0 to 5s, 9999

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

833

Speed detection filter

Second function of Pr. 823 (valid when RT terminal is on)

9999

 

"

"

"

 

 

2

0 to 5s, 9999

 

 

 

 

 

system

834

Torque control P gain

Second function of Pr. 824 (valid when RT terminal is on)

9999

 

"

"

"

 

2

0 to 200%, 9999

 

 

 

 

 

 

 

 

 

 

 

 

Control

835

Torque control

Second function of Pr. 825 (valid when RT terminal is on)

9999

 

"

"

"

836

Torque setting filter 2

Second function of Pr. 826 (valid when RT terminal is on)

9999

 

"

"

"

 

 

integral time 2

0 to 500ms, 9999

 

 

 

 

 

 

 

 

0 to 5s, 9999

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

837

Torque detection

Second function of Pr. 827 (valid when RT terminal is on)

9999

 

"

"

"

 

 

filter 2

0 to 5s, 9999

 

 

 

 

 