PARAMETERS

Function list (Extended function parameters)

 

 

 

 

 

 

 

 

 

 

 

 

At-a-glance Guide to Func-

 

 

 

 

 

 

 

 

 

 

 

 

 

tions

 

 

 

 

 

 

 

 

 

 

 

 

 

": Usable function

Function

Parameter

 

 

 

 

 

 

 

 

Cus-

×: Unusable function

 

 

 

 

 

 

 

 

 

 

 

* : Functions that can be used

 

 

 

Name

 

 

 

 

Outline

 

Factory

tomer

 

 

 

 

 

 

 

 

for param eter-set position con-

 

 

 

 

 

 

 

 

Setting

Set-

 

 

 

 

 

 

 

 

 

 

 

trol

 

 

 

 

 

 

 

 

 

 

 

 

ting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vector Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

Torque

Position

 

 

 

 

 

 

 

 

 

 

 

 

control

control

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ce

168

 

 

 

 

 

 

 

 

 

 

 

 

nteinaMa n functions

 

 

 

 

 

 

 

 

 

 

 

 

 

Maker setting parameters. Do not make setting.

 

 

 

 

 

 

 

 

 

169

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

itial nito r

171

Actual operation hour

You can clear the actual operation hour meter.

 

0

 

"

"

"

In m o

 

meter clear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DI1 terminal function

You can select the following input signals.

 

 

 

 

 

 

 

 

180

0: RL (multi-speed low-speed operation command)

Pr. 180 factory setting

0

 

"

"

"

 

 

selection

1: RM (multi-speed middle-speed operation command) Pr. 181 factory setting

 

 

 

 

 

2: RH (multi-speed high-speed operation command)

Pr. 182 factory setting

 

 

 

 

 

 

 

 

 

3: RT (second function selection) Pr. 183 factory setting

 

 

 

 

 

 

 

 

 

5: JOG (jog operation selection)

 

 

 

 

 

 

 

functions

181

DI2 terminal function

8: REX (multi-speed 15 speeds selection)

 

1

 

"

"

"

9: X9 (third function selection)

 

 

 

 

selection

11: X11 (FR-HC connection (instantaneous power failure detection)

 

 

 

 

 

 

 

 

 

10: X10 (FR-HC,FR-CV connection (inverter run enable signal))

 

 

 

 

 

assignment

 

 

12: X12 (PU operation external interlock)

 

 

 

 

 

 

 

 

20: X20 (S-pattern acceleration/deceleration C switching terminal)

 

 

 

 

 

 

 

182

DI3 terminal function

14: X14 (PID control valid)

 

 

 

 

"

"

"

 

 

selection

15: BRI (brake release completion signal)

 

2

 

 

 

 

 

16: X16 (PU operation-external operation switching)

 

 

 

 

 

 

 

 

 

 

22: X22 (orientation command)

 

 

 

 

 

 

 

Terminal

183

selection

 

 

3

 

"

"

"

25: STOP (start self-holding selection)

 

 

 

 

 

 

DI4 terminal function

23: LX (pre-excitation/servo on)

 

 

 

 

 

 

 

 

 

 

24:MRS(output stop)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26: MC (control mode switching)

 

 

 

 

 

 

 

 

 

 

 

27: TL (torque restriction selection)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STR terminal function

42: X42 (torque bias selection 1)

 

 

 

 

 

 

 

 

 

187

43: X43 (torque bias selection 2)

 

 

9999

 

"

"

"

 

 

 

selection

44: X44 (P control selection (P/PI control switching))

 

 

 

 

 

 

 

 

 

 

9999: No function (STR when set in Pr. 187)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You can select the following output signals.

 

 

 

 

 

 

 

 

 

 

0 (positive logic) Pr. 190 factory setting, 100 (negative logic): RUN (inverter running)

 

 

 

 

 

 

 

 

 

1 (positive logic) Pr.

191 factory setting, 101 (negative logic): SU (up to speed)

 

 

 

 

 

 

 

190

DO1 terminal function

2 (positive logic)

Pr. 192 factory setting, 102 (negative logic): IPF (instantaneous

0

 

"

"

"

 

 

selection

power failure or undervoltage)

 

 

 

 

 

 

3 (positive logic), 103 (negative logic)

: OL (overload alarm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 (positive logic), 104 (negative logic)

: FU (output speed detection)

 

 

 

 

 

 

 

 

 

5 (positive logic), 105 (negative logic)

: FU2 (second output speed detection)

 

 

 

 

 

 

 

 

 

6 (positive logic), 106 (negative logic)

: FU3 (third output speed detection)

 

 

 

 

 

 

 

 

 

7 (positive logic), 107 (negative logic)

: RBP (regenerative brake prealarm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 (positive logic), 108 (negative logic)

: THP (electronic thermal alarm prealarm)

 

 

 

 

 

 

 

 

 

10

(positive logic),

110 (negative logic)

: PU (PU operation mode)

 

 

 

 

 

 

 

 

 

11 (positive logic), 111 (negative logic)

: RY (inverter operation ready)

 

 

 

 

 

functions

 

DO2 terminal function

12

(positive logic),

112 (negative logic)

: Y12 (output current detection)

 

 

 

 

 

191

13 (positive logic),

113 (negative logic)

: Y13 (zero current detection)

1

 

"

"

"

selection

14 (positive logic),

114 (negative logic)

: FDN (PID lower limit)

 

 

 

 

 

15

(positive logic),

115 (negative logic)

: FUP (PID upper limit)

 

 

 

 

 

assignment

 

 

16

(positive logic),

116 (negative logic)

: RL (PID forward/reverse rotation output)

 

 

 

 

 

 

 

20

(positive logic),

120

(negative logic)

: BOF (brake opening request)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

(positive logic),

125

(negative logic)

: FAN (fan failure output)

 

 

 

 

 

 

 

 

 

26

(positive logic),

126

(negative logic)

: FIN (fin overheat prealarm)

 

 

 

 

 

 

 

 

 

27

(positive logic),

127

(negative logic)

: ORA (orientation completion)

 

 

 

 

 

Terminal

192

selection

30

(positive logic),

130

(negative logic)

: Y30 (forward rotation output)

2

 

"

"

"

33 (positive logic),

133

(negative logic)

: RY2 (operation ready 2)

 

 

 

 

 

31

(positive logic),

131

(negative logic)

: Y31 (reverse rotation output)

 

 

 

 

 

 

 

 

DO3 terminal function

32 (positive logic),

132

(negative logic)

: Y32 (regenerative status output)

 

 

 

 

 

 

 

 

 

34

(positive logic),

134

(negative logic)

: LS (low speed output)

 

 

 

 

 

 

 

 

 

35

(positive logic),

135

(negative logic)

: TU (torque detection)

 

 

 

 

 

 

 

 

 

36

(positive logic),

136

(negative logic)

: Y36 (in-position)

 

 

 

 

 

 

 

 

 

37

(positive logic),

137

(negative logic)) : MT (maintenance timer output)

 

 

 

 

 

 

 

 

 

40

(positive logic),

140

(negative logic) : Y40:(trace status)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

(positive logic),

141

(negative logic) : FB (speed detection)

 

 

 

 

 

 

 

 

 

42

(positive logic),

142

(negative logic): FB2 (second speed detection)

 

 

 

 

 

 

 

 

 

43

(positive logic),

143

(negative logic)

: FB3 (third speed detection)

 

 

 

 

 

 

 

 

A,B,C terminal

44

(positive logic), 144 (negative logic) : RUN2 (second inveter operating)

 

 

 

 

 

 

 

195

96

(positive logic),

196

(negative logic): REM (remote output)

99

 

"

"

"

 

 

function selection

 

 

 

97 (positive logic),

197

(negative logic) : ER (minor fault output 2)

 

 

 

 

 

98

(positive logic),

198

(negative logic) : LF (minor fault output)

 

 

 

 

 

 

 

 

 

99

(positive logic) Pr. 195 factory setting, 199 (negative logic): ABC (alarm output)

 

 

 

 

 

 

 

 

 

9999: No function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

61

Page 65
Image 65