1 OUTLINE

<Abbreviations>

DU: Operation panel (FR-DU04-1)

PU: Operation panel (FR-DU04-1) and parameter unit (FR-PU04V)

Inverter: Mitsubishi vector inverter FR-V500 series

FR-V500: Mitsubishi vector inverter FR-V500 series

Pr.: Parameter number

PU operation: Operation using the PU (FR-DU04-1/FR-PU04V)

External operation: Operation using the control circuit signals

Combined operation: Operation using both the PU (FR-DU04-1/FR-PU04V) and external operation

Dedicated motor: SF-V5R

Standard motor (with PLG): SF-JR

Constant-torque motor (with PLG): SF-HRCA

Harmonic Suppression Guideline

The "harmonic suppression guideline for household appliances and general-purpose products" was issued by the Ministry of Economy, Trade and Industry (formerly Ministry of International Trade and Industry) in September, 1994. This guideline applies to the 3.7K or less. By installing the power factor improving reactor (FR-BEL or FR-BAL), this product conforms to the "harmonic suppression technique for transistorized inverters (input current 20A or less)" set forth by the Japan Electrical Manufactures' Association.

For the 3.7K or more, refer to the Instruction Manual (detailed).

Product check and name of parts

Unpack the inverter and check the capacity plate on the front cover and the rating plate on the inverter side face to ensure that the product agrees with your order, an accessory L shaped jumper (Refer to page 15 for connection method.)is included, and the inverter is intact.

Plates

.

nverter type

FR - V520 - 1.5 K

 

 

 

 

 

 

Symbol

Voltage class

 

Inverter

V520

Three-phase 200V

class

capacity

V540

Three-phase 400V

class

(kW)

 

 

Rating plate

Inverter type

Input rating

Output rating

Serial number

Capacity plate

Inverter type Serial number

o. 5 terminal dedicated Lshaped jumper × 1 (supplied)

(1) Front view

 

 

 

 

 

POWER lamp

 

 

 

 

 

ALARM lamp

.

 

 

 

 

 

 

Operation panel (FR-DU04-1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brake resistor* (Fitted to the back)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessory cover

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring port cover for option

Front cover

Rating plate

Capacity plate

(2)Without front cover

PU Connector

(Provided with modular jack type relay connector)

(For use with RS-485 cable communication)

Modular jack type relay connector compartment

Inboard option mounting positions

Control circuit terminal block Main circuit terminal block

Wiring cover

*The 5.5K or less inverter is equipped with a built-in brake resistor and the 15K or less inverter is equipped with a built-in brake transistor.