!Install the inverter under the following conditions.

Vertical mounting

Ambient temperature and humidity

 

 

 

Measurement

 

 

 

position

 

5cm

Inverter

5cm

 

Measurement

5cm

 

 

 

position

 

 

Vertical

Temperature: -10°C to 50°C

Humidity: 90%RH maximum.

 

 

Leave enough clearances and take

 

cooling measures.

 

Enough clearances

10cm or more

5cm or

 

 

 

 

 

 

5cm or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

more *

 

 

 

 

 

 

more *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10cm or more

These clearances are also necessary for changing the cooling fan.

*1cm or more for 2.2K or less.

!The inverter consists of precision mechanical and electronic parts. Never install or handle it in any of the following conditions as doing so could cause an operation fault or failure.

Direct sunlight

Vertical mounting When installing two or more inverters, install them in parallel.

Vibration

High temperature,

(5.9m/s2 or more)

high humidity

Oil mist, flammable gas,

Transportation by corrosive gas, fluff, holding front cover. dust etc.

Horizontal placement

Mounting on combustible material

2

AND WIRING

!Wiring cover and handling (15K or less for the 200V class, 18.5K or less for the 400V class)

1) When cable conduits are not connected

2) When cable conduits are connected

Cut the protective bushes of the wiring cover with

Remove the corresponding protective bushes and

nippers or a cutter before running the cables.

connect the cable conduits.

Wiring cover

Protective bush

WARNING

Do not remove the protective bushes when cable conduits are not connected. Otherwise, the cable sheathes may be scratched by the wiring cover edges, resulting in a short circuit or earth (ground) fault.