Errors (Alarms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

E.OS

 

FR-PU04V

 

Overspeed occurrence

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

Overspeed

occurrence

 

 

 

 

 

Description

Indicates that the motor speed has exceeded the overspeed setting level.

Check point

• Check that the Pr. 374 "overspeed detection level" value is correct.

• Check that the number of PLG pulses differ from the actual number of PLG pulses.

 

 

 

Corrective action

• Set the Pr. 374 "overspeed detection level" value correctly.

• Set the correct number of PLG pulses in Pr. 851.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

E.OSD

 

FR-PU04V

 

Excessive speed deflection

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

Speed deviation

excess detection

 

 

 

 

 

 

Stops the inverter output if the motor speed is increased or decreased under the influence of the

Description

load etc. during vector control and cannot be controlled in accordance with the speed command

 

value.

 

 

 

 

 

 

 

 

• Check that the Pr. 870 "speed deviation level" and Pr. 871 "speed deviation time" values are

Check point

correct.

 

 

 

 

 

• Check for sudden load change.

 

 

 

 

 

 

 

 

 

 

 

 

• Check that the number of PLG pulses differ from the actual number of PLG pulses.

 

 

 

• Set the Pr. 870 "speed deviation level" and Pr. 871 "speed deviation time" values correctly.

Corrective action

• Keep load stable.

 

 

 

 

 

 

• Set the correct number of PLG pulses in Pr. 851.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

E.ECT

 

FR-PU04V

 

No encoder signal

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

Open cable

detection

 

 

 

 

 

Description

Stops the inverter output if the PLG signal is shut off.

 

 

• Check for an open cable of the PLG signal.

 

Check point

• Check that the PLG specifications are correct.

 

• Check for a loose connector.

 

 

 

 

 

 

 

 

 

 

 

 

• Check that the jumper connector of the rear of the control terminal is correctly set.

 

 

 

 

 

 

 

 

• Remedy the open cable.

 

 

 

 

 

Corrective action

• Use the PLG that meets the specifications.

 

• Make connection securely.

 

 

 

 

 

 

 

 

 

 

 

 

• Set the jumper connector of the rear of the control terminal correctly. (Refer to page 12.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

E.OD

 

FR-PU04V

 

Excessive position error

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

Position error

large

 

 

 

 

 

Description

Indicates that the difference between the position command and position feedback exceeded the

reference.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check that the position detecting encoder mounting orientation matches the parameter.

Check point

• Check that the load is not large.

 

 

 

 

 

• Check that the Pr. 427 "error excess level" and Pr. 851 "number of PLG pulses" values are

 

 

correct.

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check the parameters.

 

 

 

 

 

Corrective action

• Reduce the load weight.

 

 

 

 

 

 

• Set the Pr. 427 "error excess level" and Pr. 851 "number of PLG pulses" values correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

E.ECA

 

FR-PU04V

 

No encoder A signal

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

Orientation encoder no-signal

 

 

 

 

 

Description

The encoder pulse for the FR-V5AM or FR-A5AP is not input.

 

• Check that the FR-V5AM or FR-A5AP is connected correctly.

Check point

• Check for a loose connector.

 

 

 

 

 

• Check for an open cable.

 

 

 

 

 

 

 

 

 

 

 

 

• Check for a detector fault.

 

 

 

 

 

 

 

 

 

 

 

 

 

• Make connection securely.

 

 

 

 

 

Corrective action

• Change the cable.

 

 

 

 

 

 

• Replace the detector.

 

 

 

 

 

 

 

 

 

 

 

 

 

ERRORS AND PROTECTIVE FUNCTIONS

6

76

Page 80
Image 80
Mitsubishi Electronics FR-V500 Overspeed occurrence, Excessive speed deflection, No encoder signal, No encoder a signal