Biases and gains of speed setting termi- nals (Pr. 902 to Pr. 905, Pr. 917 to Pr. 920)

(5)-1 Method to adjust only the gain speed and not to adjust the voltage

Analog voltage A/D value

(%) across terminals 2-5

FR-DU04-1CONTROL PANEL

Hz/r

A

V

MON EXT PU

REV FWD

Press or once to display the

current analog voltage adjustment value.

Press for 1.5 s.

 

 

 

 

SET

 

 

 

 

 

Example: When the analog

Flicker

 

voltage adjustment

 

 

 

 

value is 100% (10V)

 

 

(5)-2 Method to adjust any point by application of voltage to across terminals 2-5 (e.g. applied from external potentiometer)

Analog voltage A/D value

(%) across terminals 2-5

FR-DU04-1CONTROL PANEL

Hz/r

A

V

MON EXT PU

REV FWD

Apply a 10V voltage.

(Turn the external potentiometer connected across terminals 2-5 to the maximum position.)

Press for 1.5 s

SET

Flicker

In the maximum position of the potentiometer, the value is nearly 100(%).

(5)-3 Method to adjust any point without application of voltage to across terminals 2-5 (To change from 80% to 100%)

Analog voltage A/D value

(%)across terminals 2-5 Press or once to display the current analog

FR-DU04-1

CONTROL PANEL

 

voltage adjustment value.

 

 

 

 

 

 

 

 

Hz/r

 

 

 

 

 

A

 

/

 

 

 

V

 

 

 

 

MON EXT

 

PU

 

 

 

REV

 

FWD

 

 

 

Flicker

Press / to set the gain voltage (%). "0V = 0(%), 10V = 100(%)"

Press for 1.5 s

SET

(6)Pressing SET shifts to the next parameter.

(7)Re-set the Pr. 79 "operation mode selection" value according to the operation mode being used.

CAUTION

1.Changing the Pr. 903 or Pr. 905 (gain adjustment) value will not change the Pr. 20 "acceleration/decel- eration reference speed" value. (Refer to page 54 for Pr. 20.) The input of terminal 1 (speed setting auxiliary input) is added to the speed setting signal.

2.For the operation procedure using the parameter unit (FR-PU04V), refer to the FR-PU04V instruction manual.

3.When applying voltage for calibration, the difference of the set input voltage of bias and gain should be 5% or more. If the difference is 5% or less, a setting error will occur.

CAUTION

Take care when setting any value other than "0" as the bias speed at 0V. Even if a speed command is not given, merely turning on the start signal will start the motor at the preset speed.

49

Page 53
Image 53