Desa VGMRP, CGMFN, CGMFP, VGMRN installation manual Operating Fireplace, Lighting Instructions

Page 19

OPERATING FIREPLACE

Continued

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate this fireplace with the screen in place. Make sure fireplace screen is installed before run- ning fireplace.

NOTICE: During initial opera- tion of new fireplace, burning logs will give off a paper-burn- ing smell. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information, page 18.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the safety information, page 18. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 27).

Note: You may be running this fireplace for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button (see Figure 27). This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, page 31. Also, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 20.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety inter- lock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise to ON position. The burner should light.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

ON

PILOT

OFF

Control Knob

Piezo Ignitor

 

Figure 27 - Control Knob In The OFF

Position

Thermocouple

Ignitor Electrode

 

 

Pilot Burner

Figure 28 - Natural Gas Pilot

Ignitor

Thermocouple

Pilot Burner

Electrode

Figure 29 - Propane/LP Gas Pilot

119315-01A

www.desatech.com

19

Image 19
Contents Shown with Optional Cabinet Mantel/Hearth Base Accessory OWNER’S Operation and Installation ManualTable of Contents Safety Information Unpacking Local CodesProduct Identification Product FeaturesOptional Remote Control Accessories AssemblyProviding Adequate Ventilation Air for Combustion VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Fireplace pilot and burner must be at least 18 above floor InstallationBuilt-In Fireplace Installation Fireplace ClearancesIf you have not assembled firebox, follow instructions on Mantel Clearances for Built-In InstallationPlacing Hearth Base Against Wall Route flexible gas line through access hole in hearth basePropane/LP Supply Tank External Regulator Connecting to GAS SupplyNatural Connecting Fireplace to Gas SupplyInstallation Items Needed Propane/LPTest Pressures Equal To or Less Than Psig 3.5 kPa Checking GAS ConnectionsCorrect all leaks at once Installing 9-Volt Battery in Hand-Held Remote Control Unit Optional Wireless hand-held Remote Control AccessoriesPressure Testing Fireplace Gas Connections Installing ReceiverAir conditioning ducts See FigureAs pictured in Figure Must not be lengthenedOperating Fireplace Optional Wall Switch GWMS2 Remote-Ready Models OnlyInstalling LOG SET and Screen For Your Safety Read Before LightingLighting Instructions Operating FireplaceShutting Off Fireplace Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote-ready ModelsRemote Operation Optional Hand-HeldThermostat Series Model HRC200 and HRC201 Manual ModeAuto Thermostatic Mode On/Off Series Model HRC100 and HRC101Burner Flame Pattern Switch OptionalInspecting Burners Pilot Flame PatternBlow air into the primary air holes on the injector holder Cleaning MaintenanceBurner Injector Holder Pilot Air Inlet Hole If burner flame pattern is incorrect, as shown in FigureCabinet TroubleshootingObserved Problem Possible Cause Remedy LOG SetTroubleshooting White powder residue forming When heated, vapors from Delayed ignition of burnerNoise when burner is lit Observe minimum installaGas leak. See Warning Service Hints SpecificationsWiring Diagram Replacement PartsMANUAL-controlled models Cgmfn and Cgmfp Illustrated Parts Breakdown101629-02 Parts ListIllustrated Parts Breakdown REMOTE-READY Models Equipment Shutoff Valve GA5010 AccessoriesWALL-MOUNT ON/OFF Switch Receiver and HAND-HELD Remote Control KIT HRC100 and HRC101119315-01A Not a UPC

VGMRN, VGMRP, CGMFN, CGMFP specifications

Desa CGMFP, VGMRN, VGMRP, and CGMFN represent a series of cutting-edge developments designed to optimize various aspects of modern technology and infrastructure. These entities focus on enhancing efficiency, sustainability, and overall performance within their respective domains.

Desa CGMFP, or the Comprehensive Green Manufacturing Facility Program, is dedicated to promoting sustainable manufacturing practices. Its primary features involve the integration of green technologies that minimize waste and energy consumption. The program emphasizes the use of renewable energy sources, such as solar and wind, to power manufacturing operations. This initiative not only reduces the carbon footprint of production processes but also helps organizations meet regulatory standards for environmental protection.

VGMRN, which stands for Variable Grid Management and Resource Network, is a sophisticated system designed to enhance the efficiency of energy distribution. It utilizes advanced algorithms and machine learning to manage energy loads dynamically across the grid. One of the standout characteristics of VGMRN is its ability to forecast energy demand patterns, allowing for proactive adjustments to energy supply. This results in minimized downtime and optimized usage of resources, making it an essential component of smart grid solutions.

VGMRP, or Variable Grid Management and Resource Planning, complements the work of VGMRN by focusing on the strategic planning of resource allocation within energy networks. Its core features include predictive analytics and scenario modeling, which empower utilities to simulate various energy distribution scenarios and make informed decisions. This technological approach not only aids in efficient resource use but also supports resilience against fluctuations in energy supply and demand.

Lastly, CGMFN, the Comprehensive Green Manufacturing Framework Network, provides a robust platform for collaboration across industries engaged in green manufacturing. This network facilitates the sharing of best practices, research advancements, and innovative solutions. Key characteristics of CGMFN include a strong emphasis on interdisciplinary cooperation and the promotion of circular economy principles, which encourage the utilization of recycled materials and waste reduction strategies.

Together, these initiatives encapsulate a forward-thinking approach to manufacturing and energy management. They leverage technology and strategic planning to enhance productivity while ensuring that environmental sustainability remains at the forefront of operations. As industries continue to evolve, Desa CGMFP, VGMRN, VGMRP, and CGMFN will play pivotal roles in shaping a greener, more efficient future.