Desa CGEFP33PRB, CGEFP33NRB installation manual Continued, Installation Items Needed

Page 16
Installation Items Needed

16

INSTALLATION

Installing Gas Piping to Fireplace Location (Cont.)

INSTALLATION

Continued

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer, for propane/LP units only)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by lo- cal codes) (not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 36.

For propane/LP units, the installer must supply an external regula- tor. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent point- ing down as shown in Figure 24. Pointing the vent down protects it from freezing rain or sleet.

We recommend that you install a sediment trap in supply line as shown in Figure 25. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

External

Regulator Propane/LP

Supply Tank

Vent

Pointing

Down

Figure 24 - External Regulator with Vent Pointing Down

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

Manual background CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 24).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

3" Minimum Manual backgroundManual background

Pipe Cap Tee

Nipple Joint

Sediment Trap

Figure 25 - Gas Connection

Natural

From Gas Meter (5" W.C. to 10.5" W.C. Pressure)

Propane/LP

From External Regulator (11" W.C. to 14 " W.C. Pressure

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. Never use sealant on flare threads.

Manual background WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 36.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111245-01A

Image 16
Contents CGEFP33PRB, CGEFP33NRB UNVENTED VENT-FREEGAS FIREPLACEGas Fireplace with Total Control System TCS SAFETY INFORMATION TABLE OF CONTENTSWARNINGS Continued PRODUCT IDENTIFICATIONSAFETY INFORMATION PRODUCT FEATURES LOCAL CODESUNPACKING SAFETY DEVICEAIR FOR COMBUSTION AND VENTILATION PROVIDING ADEQUATE VENTILATIONUnusually Tight Construction Confined Space and Unconfined SpaceAIR FOR COMBUSTION AND VENTILATION ContinuedVentilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONINSTALLATION AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From OutdoorsINSTALLATION INSTALLATION CLEARANCESINSTALLATION SEQUENCE REMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLYINSTALLATION ELECTRICAL CONNECTIONS FOR POWER CORDRELOCATING WALL SWITCH ASSEMBLY For Mantel InstallationINSTALLATION For Mantel InstallationContinued CAUTION Do not apply excessive pull on cordINSTALLING VARIABLE SPEED BLOWER ACCESSORY INSTALLATIONContinued 8.Plug in blower power cord INSTALLATIONContinued INSTALLATION INSTALLING THERMOSTATIC BLOWER ACCESSORYContinued Operating the Blower12.Plug in blower power cord INSTALLATIONContinued INSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONINSTALLATION ContinuedInstallation Items Needed INSTALLATIONContinued INSTALLATION Installation Items NeededPressure Testing Gas Supply Piping System ContinuedINSTALLATION Pressure Testing Fireplace Gas ConnectionsContinued necting Fireplace to Gas Supply, pageBUILT-INFIREPLACE INSTALLATION INSTALLATIONContinued INSTALLATION Mantel Clearances for Built-InInstallationContinued Brass TrimINSTALLATION INSTALLING HOODINSTALLING LOGS INSTALLATIONINSTALLATION INSTALLING BATTERY INTO REMOTEINSTALLING SCREEN INSTALLATIONOPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTINGA. Using Supplied Wall Switch Assembly NORMAL LIGHTING INSTRUCTIONSB. Using Hand-HeldWireless Remote Control Shutting Off Heater - Wall SwitchShutting Off Heater - Wireless Remote Control OPERATING FIREPLACEINSPECTING BURNERS Shutting Off Heater When Manually LitOPERATING FIREPLACE ContinuedCLEANING AND MAINTENANCE CLEANING BURNER INJECTOR HOLDERCLEANING PILOT AIR INLET HOLE LOGSTROUBLESHOOTING OBSERVED PROBLEMMaintenance, page POSSIBLE CAUSETROUBLESHOOTING OBSERVED PROBLEMContinued POSSIBLE CAUSETROUBLESHOOTING OBSERVED PROBLEMMaintenance, page ContinuedSPECIFICATIONS SERVICE HINTSTECHNICAL SERVICE REPLACEMENT PARTSWIRING DIAGRAM WIRING DIAGRAMILLUSTRATED PARTS BREAKDOWNILLUSTRATED PARTS BREAKDOWN Models CGEFP33PRB and CGEFP33NRBPARTS LIST PARTS LISTPART NUMBER CGEFP33PRBILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWNModels CGEFP33PRB and CGEFP33NRB 111245-01APARTS LIST PARTS LISTNot a field replaceable part PART NUMBERACCESSORIES TEMPLATES 3/8 Diameter 2 Holes 3/41/8 Diameter 2 Holes 3/4 4 3/4 3 3/4 3/8THIS PAGE INTENTIONALLY LEFT BLANK 111245-01AOWNERS REGISTRATION FORM Postage Required TAPETAPE 2701 Industrial Drive P.O. Box Bowling Green, KYPARTS CENTRALS Laportes Parts & ServiceBaltimore Electric Portable Heater PartsNOT A UPC 2701 Industrial Drive P.O. Box Bowling Green, KY