Desa CGEFP33PRB, CGEFP33NRB installation manual Installation, Continued, Plug in blower power cord

Page 12
8.Plug in blower power cord.

12

INSTALLATION

Installing Variable Speed Blower Accessory (Cont.)

INSTALLATION

Continued

5.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.

6.Place control knob provided on plastic control shaft of speed control.

7.Mount the speed control on the front leg of the left floor sup- port bracket using 2 screws provided (see Figure 15).

8.Plug in blower power cord.

a.If your fireplace system is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plastic bushing provided into the 1.5" hole in the floor support bracket on the exit side (see Figure 16). Install the second plastic bushing provided into the 1.5" hole in the outer casing through which the power cord will exit. Route power cord through both plastic bushings and plug the power cord into a properly grounded 3-prong wall receptacle near the firebox.

b.If your fireplace system installation is recessed and if an outlet is not installed in your fireplace, you must install the GA3555 Outlet kit with cover in your fireplace which will supply a convenient 3-prong grounded electrical outlet for your blower. Refer to the installation manual provided with the model GA3555 accessory for instructions on wir- ing the duplex outlet.

Note:A qualified installer must make all electrical connections.

9.Check to make sure that all electrical cords are completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for opera- tion. Turn blower off by rotating knob fully counterclockwise before continuing.

Manual background CAUTION: Never touch the blower wheel while in operation.

Left Floor

Support

Bracket

Speed

Control

Screws

Control

Control Shaft

Knob

Figure 15 - Attaching Speed Control to Firebox

10.Peel off backing paper and stick supplied wiring diagram de- cal near center of firebox bottom (Figure 17, page 13).

11.If gas connections have been made and checked, replace fire- place floor assembly. Feed flexible gas supply line into fire- place base area while replacing fireplace floor assembly. Make sure the entire flexible gas line is in fireplace base area.

IMPORTANT: Do not pick up fireplace floor assembly by burners. This could damage burners. Only handle base by grates. Note: Be careful of all wires and components on un- derside of floor assembly.

12.Reattach fireplace floor assembly with screws removed in step 3 of Removing Fireplace Screen and Floor Assembly, page 8.

Note: Discard the remaining hardware items. After assembly, make sure all wires are completely clear of blower wheel.

13.Install logs (see Installing Logs, pages 21 and 22) and fire- place screen (see Installing Screen, page 22).

Manual background WARNING: Failure to position the parts in accor- dance with supplied diagrams or failure to use only parts specifically approved with this heater may re- sult in damage or personal injury.

Manual background WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

Manual background Plastic

Bushing

Right Floor

Support Bracket

Figure 16 - Installing Plastic Bushing for Power Cord

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111245-01A

Image 12
Contents UNVENTED VENT-FREEGAS FIREPLACE CGEFP33PRB, CGEFP33NRBGas Fireplace with Total Control System TCS TABLE OF CONTENTS SAFETY INFORMATIONWARNINGS PRODUCT IDENTIFICATION ContinuedSAFETY INFORMATION PRODUCT FEATURES LOCAL CODESUNPACKING SAFETY DEVICEAIR FOR COMBUSTION AND VENTILATION PROVIDING ADEQUATE VENTILATIONUnusually Tight Construction Confined Space and Unconfined SpaceAIR FOR COMBUSTION AND VENTILATION ContinuedVentilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONINSTALLATION AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From OutdoorsINSTALLATION INSTALLATION CLEARANCESINSTALLATION SEQUENCE REMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLYINSTALLATION ELECTRICAL CONNECTIONS FOR POWER CORDRELOCATING WALL SWITCH ASSEMBLY For Mantel InstallationINSTALLATION For Mantel InstallationContinued CAUTION Do not apply excessive pull on cordINSTALLATION INSTALLING VARIABLE SPEED BLOWER ACCESSORYContinued INSTALLATION 8.Plug in blower power cordContinued INSTALLATION INSTALLING THERMOSTATIC BLOWER ACCESSORYContinued Operating the BlowerINSTALLATION 12.Plug in blower power cordContinued INSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONINSTALLATION ContinuedINSTALLATION Installation Items NeededContinued INSTALLATION Installation Items NeededPressure Testing Gas Supply Piping System ContinuedINSTALLATION Pressure Testing Fireplace Gas ConnectionsContinued necting Fireplace to Gas Supply, pageINSTALLATION BUILT-INFIREPLACE INSTALLATIONContinued INSTALLATION Mantel Clearances for Built-InInstallationContinued Brass TrimINSTALLATION INSTALLING HOODINSTALLING LOGS INSTALLATIONINSTALLATION INSTALLING BATTERY INTO REMOTEINSTALLING SCREEN INSTALLATIONOPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTINGA. Using Supplied Wall Switch Assembly NORMAL LIGHTING INSTRUCTIONSB. Using Hand-HeldWireless Remote Control Shutting Off Heater - Wall SwitchShutting Off Heater - Wireless Remote Control OPERATING FIREPLACEINSPECTING BURNERS Shutting Off Heater When Manually LitOPERATING FIREPLACE ContinuedCLEANING AND MAINTENANCE CLEANING BURNER INJECTOR HOLDERCLEANING PILOT AIR INLET HOLE LOGSTROUBLESHOOTING OBSERVED PROBLEMMaintenance, page POSSIBLE CAUSETROUBLESHOOTING OBSERVED PROBLEMContinued POSSIBLE CAUSETROUBLESHOOTING OBSERVED PROBLEMMaintenance, page ContinuedSPECIFICATIONS SERVICE HINTSTECHNICAL SERVICE REPLACEMENT PARTSWIRING DIAGRAM WIRING DIAGRAMILLUSTRATED PARTS BREAKDOWNILLUSTRATED PARTS BREAKDOWN Models CGEFP33PRB and CGEFP33NRBPARTS LIST PARTS LISTPART NUMBER CGEFP33PRBILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWNModels CGEFP33PRB and CGEFP33NRB 111245-01APARTS LIST PARTS LISTNot a field replaceable part PART NUMBERACCESSORIES TEMPLATES 3/8 Diameter 2 Holes 3/41/8 Diameter 2 Holes 3/4 4 3/4 3 3/4 3/8THIS PAGE INTENTIONALLY LEFT BLANK 111245-01AOWNERS REGISTRATION FORM Postage Required TAPETAPE 2701 Industrial Drive P.O. Box Bowling Green, KYPARTS CENTRALS Laportes Parts & ServiceBaltimore Electric Portable Heater PartsNOT A UPC 2701 Industrial Drive P.O. Box Bowling Green, KY