Desa CGEFP33PRB, CGEFP33NRB Specifications, Service Hints, Technical Service, Replacement Parts

Page 30
SPECIFICATIONS

30

SPECIFICATIONS

SERVICE HINTS TECHNICAL SERVICE REPLACEMENT PARTS

SPECIFICATIONS

Btu (Variable)

20,000/33,000

 

Type Gas

Natural: CGEFP33NRB

 

Propane/LP: CGEFP33PRB

Ignition

Electronic (Automatic)/Piezo (Manual)

 

Natural Gas

Propane/LP Gas

Manifold Pressure

3.5" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

14"

Minimum*

5"

11"

Shipping Weight

122 lbs.

122 lbs.

* For input adjustment

 

 

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical service web site at www.desatech.com.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product or Parts Central (see page 41). If they can’t supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your fireplace

the replacement part number

SERVICE HINTSWhen Gas Pressure Is Too LowTECHNICAL SERVICEREPLACEMENT PARTSManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111245-01A

Image 30
Contents UNVENTED VENT-FREEGAS FIREPLACE CGEFP33PRB, CGEFP33NRBGas Fireplace with Total Control System TCS TABLE OF CONTENTS SAFETY INFORMATIONWARNINGS PRODUCT IDENTIFICATION ContinuedSAFETY INFORMATION UNPACKING PRODUCT FEATURESLOCAL CODES SAFETY DEVICEUnusually Tight Construction AIR FOR COMBUSTION AND VENTILATIONPROVIDING ADEQUATE VENTILATION Confined Space and Unconfined SpaceVentilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONContinued AIR FOR COMBUSTION AND VENTILATIONContinued INSTALLATIONAIR FOR COMBUSTION AND VENTILATION Ventilation Air From OutdoorsINSTALLATION SEQUENCE INSTALLATIONINSTALLATION CLEARANCES REMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLYRELOCATING WALL SWITCH ASSEMBLY INSTALLATIONELECTRICAL CONNECTIONS FOR POWER CORD For Mantel InstallationContinued INSTALLATIONFor Mantel Installation CAUTION Do not apply excessive pull on cordINSTALLATION INSTALLING VARIABLE SPEED BLOWER ACCESSORYContinued INSTALLATION 8.Plug in blower power cordContinued Continued INSTALLATIONINSTALLING THERMOSTATIC BLOWER ACCESSORY Operating the BlowerINSTALLATION 12.Plug in blower power cordContinued INSTALLATION INSTALLATIONINSTALLING GAS PIPING TO FIREPLACE LOCATION ContinuedINSTALLATION Installation Items NeededContinued Pressure Testing Gas Supply Piping System INSTALLATIONInstallation Items Needed ContinuedContinued INSTALLATIONPressure Testing Fireplace Gas Connections necting Fireplace to Gas Supply, pageINSTALLATION BUILT-INFIREPLACE INSTALLATIONContinued Continued INSTALLATIONMantel Clearances for Built-InInstallation Brass TrimINSTALLING LOGS INSTALLATIONINSTALLING HOOD INSTALLATIONINSTALLING SCREEN INSTALLATIONINSTALLING BATTERY INTO REMOTE INSTALLATIONA. Using Supplied Wall Switch Assembly OPERATING FIREPLACEFOR YOUR SAFETY READ BEFORE LIGHTING NORMAL LIGHTING INSTRUCTIONSShutting Off Heater - Wireless Remote Control B. Using Hand-HeldWireless Remote ControlShutting Off Heater - Wall Switch OPERATING FIREPLACEOPERATING FIREPLACE INSPECTING BURNERSShutting Off Heater When Manually Lit ContinuedCLEANING PILOT AIR INLET HOLE CLEANING AND MAINTENANCECLEANING BURNER INJECTOR HOLDER LOGSMaintenance, page TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEContinued TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEMaintenance, page TROUBLESHOOTINGOBSERVED PROBLEM ContinuedTECHNICAL SERVICE SPECIFICATIONSSERVICE HINTS REPLACEMENT PARTSWIRING DIAGRAM WIRING DIAGRAMILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTSBREAKDOWN Models CGEFP33PRB and CGEFP33NRBPART NUMBER PARTS LISTPARTS LIST CGEFP33PRBModels CGEFP33PRB and CGEFP33NRB ILLUSTRATED PARTS BREAKDOWNILLUSTRATED PARTS BREAKDOWN 111245-01ANot a field replaceable part PARTS LISTPARTS LIST PART NUMBERACCESSORIES 1/8 Diameter 2 Holes 3/4 TEMPLATES3/8 Diameter 2 Holes 3/4 4 3/4 3 3/4 3/8THIS PAGE INTENTIONALLY LEFT BLANK 111245-01AOWNERS REGISTRATION FORM TAPE Postage RequiredTAPE 2701 Industrial Drive P.O. Box Bowling Green, KYBaltimore Electric PARTS CENTRALSLaportes Parts & Service Portable Heater PartsNOT A UPC 2701 Industrial Drive P.O. Box Bowling Green, KY