Desa CGEFP33NRB, CGEFP33PRB Product Identification, Continued, Safety Information

Page 3
Continued

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Lo- cate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, ver- miculite, or rock wool. Using these added items can cause soot- ing. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 26.

8.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 7. If fireplace keeps shutting off, see Trouble- shooting, pages 27 through 29.

10.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the fireplace and to replace any part of the control sys- tem and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servicing. Only a quali- fied service person should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

SAFETY INFORMATION

3

PRODUCT IDENTIFICATION

16.To prevent performance problems with propane/LP units, do not use propane/LP fuel tanks of less than 100 lb. capacity.

17.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

Log Set

Manual Override

Handle

Remote

Control Piezo

Ignitor

Wall Switch

Manual Ignition

Assembly

Bypass Switch

Figure 1 - Fireplace Floor Assembly

Top Outer

Casing

Top Louver

Assembly

Firebox

Hood

Firebox Support

Screen

Assembly

Blower

Bottom Louver Assembly

Assembly(Optional)

Figure 2 - Fireplace

PRODUCT IDENTIFICATIONFor moreFor morevisit www..comManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111245-01A

Image 3
Contents UNVENTED VENT-FREEGAS FIREPLACE CGEFP33PRB, CGEFP33NRBGas Fireplace with Total Control System TCS TABLE OF CONTENTS SAFETY INFORMATIONWARNINGS PRODUCT IDENTIFICATION ContinuedSAFETY INFORMATION SAFETY DEVICE PRODUCT FEATURESLOCAL CODES UNPACKINGConfined Space and Unconfined Space AIR FOR COMBUSTION AND VENTILATIONPROVIDING ADEQUATE VENTILATION Unusually Tight ConstructionAIR FOR COMBUSTION AND VENTILATION AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From Inside BuildingVentilation Air From Outdoors INSTALLATIONAIR FOR COMBUSTION AND VENTILATION ContinuedREMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLY INSTALLATIONINSTALLATION CLEARANCES INSTALLATION SEQUENCEFor Mantel Installation INSTALLATIONELECTRICAL CONNECTIONS FOR POWER CORD RELOCATING WALL SWITCH ASSEMBLYCAUTION Do not apply excessive pull on cord INSTALLATIONFor Mantel Installation ContinuedINSTALLATION INSTALLING VARIABLE SPEED BLOWER ACCESSORYContinued INSTALLATION 8.Plug in blower power cordContinued Operating the Blower INSTALLATIONINSTALLING THERMOSTATIC BLOWER ACCESSORY ContinuedINSTALLATION 12.Plug in blower power cordContinued Continued INSTALLATIONINSTALLING GAS PIPING TO FIREPLACE LOCATION INSTALLATIONINSTALLATION Installation Items NeededContinued Continued INSTALLATIONInstallation Items Needed Pressure Testing Gas Supply Piping Systemnecting Fireplace to Gas Supply, page INSTALLATIONPressure Testing Fireplace Gas Connections ContinuedINSTALLATION BUILT-INFIREPLACE INSTALLATIONContinued Brass Trim INSTALLATIONMantel Clearances for Built-InInstallation ContinuedINSTALLATION INSTALLATIONINSTALLING HOOD INSTALLING LOGSINSTALLATION INSTALLATIONINSTALLING BATTERY INTO REMOTE INSTALLING SCREENNORMAL LIGHTING INSTRUCTIONS OPERATING FIREPLACEFOR YOUR SAFETY READ BEFORE LIGHTING A. Using Supplied Wall Switch AssemblyOPERATING FIREPLACE B. Using Hand-HeldWireless Remote ControlShutting Off Heater - Wall Switch Shutting Off Heater - Wireless Remote ControlContinued INSPECTING BURNERSShutting Off Heater When Manually Lit OPERATING FIREPLACELOGS CLEANING AND MAINTENANCECLEANING BURNER INJECTOR HOLDER CLEANING PILOT AIR INLET HOLEPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM Maintenance, pagePOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM ContinuedContinued TROUBLESHOOTINGOBSERVED PROBLEM Maintenance, pageREPLACEMENT PARTS SPECIFICATIONSSERVICE HINTS TECHNICAL SERVICEWIRING DIAGRAM WIRING DIAGRAMModels CGEFP33PRB and CGEFP33NRB ILLUSTRATED PARTSBREAKDOWN ILLUSTRATED PARTS BREAKDOWNCGEFP33PRB PARTS LISTPARTS LIST PART NUMBER111245-01A ILLUSTRATED PARTS BREAKDOWNILLUSTRATED PARTS BREAKDOWN Models CGEFP33PRB and CGEFP33NRBPART NUMBER PARTS LISTPARTS LIST Not a field replaceable partACCESSORIES 4 3/4 3 3/4 3/8 TEMPLATES3/8 Diameter 2 Holes 3/4 1/8 Diameter 2 Holes 3/4111245-01A THIS PAGE INTENTIONALLY LEFT BLANKOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredTAPE TAPEPortable Heater Parts PARTS CENTRALSLaportes Parts & Service Baltimore Electric2701 Industrial Drive P.O. Box Bowling Green, KY NOT A UPC