Desa CGEFP33NRB, CGEFP33PRB installation manual Continued, Built-Infireplace Installation

Page 19
BUILT-IN FIREPLACE INSTALLATION

INSTALLATION

Conventional Fireplace Installation (Cont.) Built-In Fireplace Installation

19

INSTALLATION

Continued

11.Carefully insert fireplace into cabinet mantel (see Figure 33). Be careful not to scratch or damage hearth base, cabinet man- tel, or any laminate trim on hearth base. Remove protective material from top of hearth base and from front of fireplace (if any). Note: You can secure fireplace to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Tighten wood screws through these holes and into hearth or floor.

12.Check all gas connections for leaks. See Checking Gas Con- nections, pages 17 and 18.

Cabinet

Manual background Mantel

Figure 31 - Installing Cabinet Mantel

Nailing Flanges

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 37, page 20. Follow the instructions below to install the fireplace in this manner.

 

Actual

Framing

 

 

 

Height

32 3/ "

33"

 

8

 

Front Width

34 5/16"

35 1/2"

Depth

16 11/16"

17 3/4"

1.Frame in rough opening. Use dimensions shown in Figure 34 for the rough opening. If installing in a corner, use dimensions shown in Figure 35 for the rough opening. The height is 33" which is the same as the wall opening above.

2.Install and properly ground GA3555, three-prong 120 volt elec- trical outlet, in fireplace. Follow instructions included in kit (see Accessories, page 36).

3.If not already completed, install gas piping to fireplace location. This installation includes an approved flexible gas line (if al- lowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas pip- ing. See Installing Gas Piping to Fireplace Location, page 15.

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Attach flexible gas line to gas supply. See Connecting Fire- place to Gas Supply, page 16.

6.Plug electrical cord(s) into electrical outlet installed in step 2.

7.Carefully insert fireplace into rough opening.

Figure 32 - Location of Nailing Flanges

Figure 33 - Inserting Fireplace Into Cabinet Mantel

17 3/4"

33"

Manual backgroundManual background 35 1/2" Manual background

Figure 34 - Rough Opening for Installing in Wall

393/8"

27 7/8"

Manual background 35 1/2"Manual background 55 5/8"

Figure 35 - Rough Opening for Installing in Corner

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111245-01A

Image 19
Contents CGEFP33PRB, CGEFP33NRB UNVENTED VENT-FREEGAS FIREPLACEGas Fireplace with Total Control System TCS SAFETY INFORMATION TABLE OF CONTENTSWARNINGS Continued PRODUCT IDENTIFICATIONSAFETY INFORMATION SAFETY DEVICE PRODUCT FEATURESLOCAL CODES UNPACKINGConfined Space and Unconfined Space AIR FOR COMBUSTION AND VENTILATIONPROVIDING ADEQUATE VENTILATION Unusually Tight ConstructionAIR FOR COMBUSTION AND VENTILATION AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From Inside BuildingVentilation Air From Outdoors INSTALLATIONAIR FOR COMBUSTION AND VENTILATION ContinuedREMOVING FIREPLACE SCREEN AND FLOOR ASSEMBLY INSTALLATIONINSTALLATION CLEARANCES INSTALLATION SEQUENCEFor Mantel Installation INSTALLATIONELECTRICAL CONNECTIONS FOR POWER CORD RELOCATING WALL SWITCH ASSEMBLYCAUTION Do not apply excessive pull on cord INSTALLATIONFor Mantel Installation ContinuedINSTALLING VARIABLE SPEED BLOWER ACCESSORY INSTALLATIONContinued 8.Plug in blower power cord INSTALLATIONContinued Operating the Blower INSTALLATIONINSTALLING THERMOSTATIC BLOWER ACCESSORY Continued12.Plug in blower power cord INSTALLATIONContinued Continued INSTALLATIONINSTALLING GAS PIPING TO FIREPLACE LOCATION INSTALLATIONInstallation Items Needed INSTALLATIONContinued Continued INSTALLATIONInstallation Items Needed Pressure Testing Gas Supply Piping Systemnecting Fireplace to Gas Supply, page INSTALLATIONPressure Testing Fireplace Gas Connections ContinuedBUILT-INFIREPLACE INSTALLATION INSTALLATIONContinued Brass Trim INSTALLATIONMantel Clearances for Built-InInstallation ContinuedINSTALLATION INSTALLATIONINSTALLING HOOD INSTALLING LOGSINSTALLATION INSTALLATIONINSTALLING BATTERY INTO REMOTE INSTALLING SCREENNORMAL LIGHTING INSTRUCTIONS OPERATING FIREPLACEFOR YOUR SAFETY READ BEFORE LIGHTING A. Using Supplied Wall Switch AssemblyOPERATING FIREPLACE B. Using Hand-HeldWireless Remote ControlShutting Off Heater - Wall Switch Shutting Off Heater - Wireless Remote ControlContinued INSPECTING BURNERSShutting Off Heater When Manually Lit OPERATING FIREPLACELOGS CLEANING AND MAINTENANCECLEANING BURNER INJECTOR HOLDER CLEANING PILOT AIR INLET HOLEPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM Maintenance, pagePOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM ContinuedContinued TROUBLESHOOTINGOBSERVED PROBLEM Maintenance, pageREPLACEMENT PARTS SPECIFICATIONSSERVICE HINTS TECHNICAL SERVICEWIRING DIAGRAM WIRING DIAGRAMModels CGEFP33PRB and CGEFP33NRB ILLUSTRATED PARTSBREAKDOWN ILLUSTRATED PARTS BREAKDOWNCGEFP33PRB PARTS LISTPARTS LIST PART NUMBER111245-01A ILLUSTRATED PARTS BREAKDOWNILLUSTRATED PARTS BREAKDOWN Models CGEFP33PRB and CGEFP33NRBPART NUMBER PARTS LISTPARTS LIST Not a field replaceable partACCESSORIES 4 3/4 3 3/4 3/8 TEMPLATES3/8 Diameter 2 Holes 3/4 1/8 Diameter 2 Holes 3/4111245-01A THIS PAGE INTENTIONALLY LEFT BLANKOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredTAPE TAPEPortable Heater Parts PARTS CENTRALSLaportes Parts & Service Baltimore Electric2701 Industrial Drive P.O. Box Bowling Green, KY NOT A UPC