Desa MSBVBP Inspecting Burners, Operating Optional GWMT1 Wall Mounted Thermostat, Pilot Assembly

Page 20

SUN VALLEY STOVE COMPANY

B-VENT FREESTANDING FIREPLACE

OPERATING

FIREPLACE

Continued

OPERATING

OPTIONAL GWMT1

WALL MOUNTED

THERMOSTAT

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire haz- ard will occur.

Light the fireplace as instructed in Light- ing Instructions on page 18. Set wall ther- mostat to desired temperature.

Upon installation, the thermostat must be allowed to stabilize at room tempera- ture for a minimum of 30 minutes for properoperation.

To turn the fireplace off, adjust thermo- stat to the lowest setting and turn the gas control knob back to PILOT. The pilot willremainlit.

IMPORTANT: To turn the pilot off, turn the control knob on the heater to the OFF position.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

If the vent configuration is installed incor- rectly, the flames will lift or “ghost”. This can be dangerous. Inspect the flames after installation to ensure proper installation and performance.

Figure 53 shows a typical flame pattern. If burnerflamepatterndiffersfromthatdescribed:

turn fireplace off (seeTo Turn Off Gas to Appliance, page 18)

seeTroubleshooting, pages 22 through 24

This thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.

OPERATING

OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just insidethelouverpanel.

BoththeGA3700manualblowerandthe DA3610T thermostatically -controlled blower have an ON setting and an OFF setting.Theblowerwillonlyrunwhenthe switch is in the ON position. In the OFF position,theblowerwillnotoperate.

Note for DA3610T Only: If you are usingDA3610Tblowerwithoptionalther- mostat (wall mount or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on.Aftertheheatermodulatestothepilot position,theblowerwillcontinuetorun. The blower will shut off after the firebox temperaturedecreases.

The blower helps distribute heated air fromthefireplace.Periodicallycheckthe louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to

 

1/2" above the pilot flame as shown in

 

Figure 52. The flame from the pilot burner

Figure 53 - Typical Flame Pattern

must extend beyond the thermopile.

 

If your pilot assembly does not meet these requirements:

turn fireplace off (seeTo Turn Off Gas to Appliance, page 18)

seeTroubleshooting, pages 22 through 24

Thermopile

3/8" to 1/2"

Pilot Burner

Piezo Ignitor

Figure 52 - Pilot Assembly

20

106022

Image 20
Contents MSBVBN, Msbvbp Remote Ready For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information SUN Valley Stove CompanyProduct Features Product Identification Local CodesOperation Piezo IgnitorPRE-INSTALLATION Preparation Location and Space RequirementsFreestanding Fireplace Assembly Stove Body AssemblyLift off corrugated box enclosing stove body crating Remove plastic bag from stove bodySet three top grate sections into stove top Attaching Stove LegsInstalling GA3700/DA3610T Blowers Installing Fireplace Into Stove BodyInstalling Optional Blower Accessory Installation Precautions Venting InstallationInstalling Rear Cover Installation of Listed B-1 Vent Use only vents labeled for EXTE- Rior USE above the rooflineInstalling Vent System in a Chase Checking Vent CapacityChimneys Relining SystemsTroubleshooting Venting Problems High Altitude InstallationFlue GAS Spillage Causes of Spillage and Corrective ActionFireplace Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Open manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsClose manual shutoff valve see Fig- ure Installing Optional Wall Mounted Thermostat GWMT1, GWMS2 REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing LOGS, Lava Rock and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOptional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrct Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsPressed in 30 seconds TroubleshootingAfter pilot lights, keep control knob Orifice Inlet gas pressure is too lowCompany Pane/LP or natural gas companyFireplace produces unwanted odors Pilot is partially cloggedNance, Inner vent pipe leaking exhaust gassesReplacement Parts Technical ServiceWiring Diagram Service HintsSpecifications Msbvbn MsbvbpAccessories Illustrated Parts Breakdown Msbvbn MsbvbpParts List KEY Part Number Description QTYSUN Valley Stove MC* Series Indicates Color Suffix DesignationKEY Part Description QTY Warranty Information International