Desa MSBVBN, MSBVBP Installing Fireplace Into Stove Body, Installing Optional Blower Accessory

Page 7

OWNER’S MANUAL

FREESTANDING FIREPLACE ASSEMBLY

Continued

INSTALLING FIREPLACE INTO STOVE BODY

1. Attach the two brackets to the back of the stove (see Figure 17). Use the screws and washers from step 4 of Stove Body Assembly on page 5.

2. Carefully lift firebox and place into

stove body from the rear of stove.

3. Using screws provided, attach firebox

1.Remove the two hex head screws on the blower assembly as shown in Figure 18.

2.Place the green wire between the bot- tom hole on the thermal switch bracket and the bottom hole on the blower as- sembly. Insert one of the hex screws into all three pieces and tighten.

3.Insert the top screw through the ther- mal switch bracket and into the blower assembly. Tighten screw.

4.Connect the blue wire on the blower assembly to the right side of the ther- mal switch.

5.Connect the black wire to the left side of the thermal switch.

Black

Installing GA3700/DA3610T Blowers

1.

Align the holes in the top mounting tabs

 

of blower with holes in wall of rear

 

cover (see Figure 19). Using the 4

 

screws provided, mount blower and

 

tighten screws securely.

 

Note: For DA3610T, make sure the ther-

 

mal switch has been properly installed

 

to fit against the back of the firebox.

2.

Make sure all wire connections to ter-

 

minals on blower motor (and thermal

 

switch where applicable) are securely

 

attached and that the screw retaining

 

the green ground wire is tight.

3.

Place speed control on left inside of rear

to back of stove.

Insert

Assembly

Cast Iron

Stove Body

Screw

Wire

White Wire

Blower

 

 

Assembly

Thermal

Green

Switch

Wire

with

Blue Wire

Bracket

Hex Head

 

 

Screws

Figure 18 - Attaching Thermal Switch to DA3610T Thermostatically Controlled Blower Accessory

cover and push the plastic control shaft

through opening (see Figure 19).

4. While supporting speed control, secure

control shaft with lock nut by pushing and

turning lock nut with pliers clockwise

until tight against the side of rear cover.

Place control knob provided onto shaft

(see Figure 19).

5. Plug in blower power cord.

6. Check to make sure that the power cord

is completely clear of the blower wheel

and that there are no other foreign ob-

jects in blower wheel. Turn blower on

and check for operation. Turn blower

off by rotating knob fully counterclock-

wise before continuing.

Figure 17 - Installing Firebox Into Cast Iron Stove Body

INSTALLING OPTIONAL BLOWER ACCESSORY

NOTICE: If installing blower in an existing fireplace with gas con- nections, shut off gas supply and disconnect heater from gas sup- ply. Contact a qualified service person to do this.

Attaching Thermal Switch to DA3610T Thermostatically- Controlled Blower

When installing the DA3610T thermostati- cally-controlled blower accessory, you must first secure the thermal switch to the blower.

Blower

Control

Control Knob

Shaft

Lock

Speed Control

 

Nut

Power Cord

 

Mounting Screws (Included in Hardware Pack)

White

Black

 

Wire

Wiring

Wire

 

 

 

Diagram

 

 

Decal

Blue

 

Rear Cover

Wire

Green

 

Ground Wire

Blower

 

 

Figure 19 - Installing Optional Blower Accessory (Thermostat Model DA3610T Shown)

Continued

106022

7

Image 7
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyMSBVBN, Msbvbp Remote Ready SUN Valley Stove Company Safety InformationPiezo Ignitor Product FeaturesProduct Identification Local Codes OperationLocation and Space Requirements PRE-INSTALLATION PreparationRemove plastic bag from stove body Freestanding Fireplace AssemblyStove Body Assembly Lift off corrugated box enclosing stove body cratingAttaching Stove Legs Set three top grate sections into stove topInstalling Optional Blower Accessory Installing Fireplace Into Stove BodyInstalling GA3700/DA3610T Blowers Installing Rear Cover Venting InstallationInstallation Precautions Use only vents labeled for EXTE- Rior USE above the roofline Installation of Listed B-1 VentRelining Systems Installing Vent System in a ChaseChecking Vent Capacity ChimneysCauses of Spillage and Corrective Action Troubleshooting Venting ProblemsHigh Altitude Installation Flue GAS SpillageCheck GAS Type Fireplace InstallationInstalling GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Close manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsOpen manual shutoff valve see Fig- ure Installing Optional Wall Mounted Thermostat GWMT1, GWMS2 Installing 9-Volt Battery in Hand- Held Remote Control Unit Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing Log No Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceGhrct Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersAfter pilot lights, keep control knob TroubleshootingPressed in 30 seconds Pane/LP or natural gas company OrificeInlet gas pressure is too low CompanyInner vent pipe leaking exhaust gasses Fireplace produces unwanted odorsPilot is partially clogged Nance,Service Hints Replacement PartsTechnical Service Wiring DiagramMsbvbn Msbvbp SpecificationsAccessories Msbvbn Msbvbp Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation SUN Valley Stove MC* SeriesKEY Part Description QTY International Warranty Information