Vermont Casting DVRT43 Vermont Castings, Majestic Products DVRT36/39/43, Canadian Installations1

Page 12
Canadian Installations1

Vermont Castings, Majestic Products DVRT36/39/43

General Venting Information - Termination Location

 

 

INSIDE

 

 

 

CORNER DETAIL

 

 

 

G

 

 

 

V

N

 

 

H

D

A

N

 

 

E

 

 

 

V

 

 

V

L

B

 

 

C

 

V

Fixed

 

 

Closed

F

V

Operable

 

 

 

B

B

V

US Installations2B

 

B

 

V

Operable

Fixed

 

 

Closed

 

 

 

 

 

 

 

 

B

V

J

X

M

 

AManual background I

VManual background KManual backgroundX

Manual background G

Manual background G

A

V

V

V

CFM145a

VENT TERMINATION X AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

 

 

 

Canadian Installations1

US Installations2

 

 

A = Clearance above grade, veranda, porch,

12” (30cm)

12” (30cm)

 

 

deck, or balcony

 

 

 

 

B = Clearance to window or door that may be

6” (15cm) for appliances

6” (15cm) for appliances

 

 

opened

< 10,000Btuh (3kW), 12” (30cm)

< 10,000 Btuh (3kW), 9”

 

 

 

for appliances > 10,000 Btuh (3kW) and

(23cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

C = Clearance to permanently closed window

12” (305mm) recommended to

12” (305mm) recommended to

 

 

 

prevent window condensation

prevent window condensation

 

D = Vertical clearance to ventilated soffit located

 

 

 

 

 

above the terminal within a horizontal

18” (458mm)

18” (458mm)

 

 

distance of 2 feet (610mm) from the center

 

 

 

 

 

line of the terminal

 

 

 

 

E = Clearance to unventilated soffit

12” (305mm)

12” (305mm)

 

F =

Clearance to outside corner

see next page

see next page

 

G = Clearance to inside corner (see next page)

see next page

see next page

 

H = Clearance to each inside of center line

3’ (91cm) within a height of 15’

3’ (91cm) within a height of 15’

 

 

extended above meter/regulator assembly

above the meter/regulator assembly

above the meter/regulator assy

 

I =

Clearance to service regulator vent outlet

3’ (91cm)

3’ (91cm)

 

J =

Clearance to nonmechanical air supply inlet

6” (15cm) for appliances < 10,000

6” (15cm) for appliances

 

 

to building or the combustion air inlet to any

Btuh (3kW), 12” (30cm) for

< 10,000 Btuh (3kW), 9”

 

 

other appliances

appliances > 10,000 Btuh (3kW) and <

(23cm) for appliances > 10,000

 

 

 

100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

K = Clearance to a mechanical air supply inlet

6’ (1.83m)

3’ (91cm) above if within 10’

 

 

 

 

(3m) horizontally

 

L =

Clearance above paved sidewalk or paved

7’ (2.13m)†

7’ (2.13m)†

 

 

driveway located on public property

 

 

 

 

M = Clearance under veranda, porch, deck or

12” (30cm)‡

12” (30cm)‡

 

 

balcony

 

 

 

N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm).

1In accordance with the current CSA-B149 Installation Codes

2In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes

A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings a nd serves both dwellings

‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.

2.The special venting system used on Vermont Castings, Majestic Products Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency.

Fig. 14 Vent termination clearances.

12

10002428

Image 12
Contents Homeowners Installation Direct Vent Models DVRT36 DVRT39 DVRT43Vermont Castings, Majestic Products INSTALLER/CONSUMER SAFETY INFORMATIONTable of Contents Vermont Castings, Majestic Products DVRT36/39/43Installation & Operating Instructions Venting Installation InstructionsInstallation & Operating Instructions Locating the FireplaceVermont Castings, Majestic Products DVRT36/39/43 10002428Fireplace Dimensions Installed as Top Vent Framing DimensionsVermont Castings, Majestic Products DVRT36/39/43 DVRT36Fireplace Dimensions Installed as Rear Vent Vermont Castings, Majestic Products DVRT36/39/4310002428 Clearance to Combustibles MantelsHearth Vermont Castings, Majestic Products DVRT36/39/43Gas Specifications Framing & FinishingFinal Finishing Gas Inlet and Manifold PressuresGas Line Installation Remote ON/ OFF Switch InstallationAlternate Switch Location Vermont Castings, Majestic Products DVRT36/39/43EB-1Electrical Box Electronic Gas Control ValveVermont Castings, Majestic Products DVRT36/39/43 10002428Installing the DVRT36RMH in a Mobile Home Optional Top Vent ApplicationVermont Castings, Majestic Products DVRT36/39/43 10002428General Venting Vermont Castings, Majestic Products DVRT36/39/4310002428 Canadian Installations1 US Installations2Vermont Castings, Majestic Products DVRT36/39/43 10002428General Information for Connecting Vent Pipes Crimped End PipesVermont Castings, Majestic Products DVRT36/39/43 10002428How to Use the Vent Graph Twist-lockPipesRear Wall Vent Application Vermont Castings, Majestic Products DVRT36/39/43Rear Wall Vent Installation Vermont Castings, Majestic Products DVRT36/39/43Step StepVertical Sidewall Application Vermont Castings, Majestic Products DVRT36/39/4310002428 Vertical Sidewall Installation Vermont Castings, Majestic Products DVRT36/39/4310002428 Below Grade Installation Vermont Castings, Majestic Products DVRT36/39/4310002428 Vertical Through-the-RoofApplication Vermont Castings, Majestic Products DVRT36/39/43Do not backfill around snorkel 10002428Vertical Through-the-RoofInstallation Vermont Castings, Majestic Products DVRT36/39/4310002428 Gravity Ducting System Vermont Castings, Majestic Products DVRT36/39/43Clearance to Combustibles Min 2’ 610 mmVermont Castings, Majestic Products DVRT36/39/43 Sheet MetalGravity ScrewsTwist Lock Venting Components Vermont Castings, Majestic Products DVRT36/39/4310002428 Crimped End Venting Components Vermont Castings, Majestic Products DVRT36/39/4310002428 Window Frame Assembly Removal Glass CleaningOperating Instructions Glass InformationInstallation of Logs & Lava Rock Vermont Castings, Majestic Products DVRT36/39/4310002428 Flame & Temperature Adjustment Flame CharacteristicsVermont Castings, Majestic Products DVRT36/39/43 10002428Inspecting the Venting System Vermont Castings, Majestic Products DVRT36/39/4310002428 FOR YOUR SAFETY, READ BEFORE LIGHTING Lighting & Operating InstructionsLighting Instructions To Turn Off Gas to HeaterFor Your Safety, Read the Following Warnings before Lighting the ApplianceTurning Off the Gas to the Appliance Vermont Castings, Majestic Products DVRT36/39/43Shutoff Procedure Instructions for RF Comfort Control ValveOperation of RF Comfort Control Valve Transmitter OperationDisable Thermostat Function Troubleshooting RF Comfort Control ValveDelay Time Mode Auto ModeAuto Path Chart Vermont Castings, Majestic Products DVRT36/39/43Auto Path 10002428Vermont Castings, Majestic Products DVRT36/39/43 10002428LOCAL to RE LOCALTroubleshooting - Honeywell VS8421 Vermont Castings, Majestic Products DVRT36/39/4310002428 Troubleshooting the Gas Control System SYMPTOMVermont Castings, Majestic Products DVRT36/39/43 SIT NOVA 820 MILLIVOLT VALVETroubleshooting the Gas Control System Vermont Castings, Majestic Products DVRT36/39/43SIT 822 Valve with a Honeywell Electronic Igniter STARTFuel Conversion Instructions Vermont Castings, Majestic Products DVRT36/39/4310002428 Maintenance Cleaning the Standing Pilot Control SystemVermont Castings, Majestic Products DVRT36/39/43 10002428DVRT36/39/43 Vermont Castings, Majestic Products DVRT36/39/4310002428 DVRT43Vermont Castings, Majestic Products DVRT36/39/43 DescriptionDVRT36 DVRT39DVRT36/39/43 continued Vermont Castings, Majestic Products DVRT36/39/4310002428 Optional Accessories Hard Direct Wire HookupFan Kits Vermont Castings, Majestic Products DVRT36/39/43Remote Controls Ceramic Refractory PanelsDecorative Bay Window Vermont Castings, Majestic Products DVRT36/39/43Decorative Frame Trim Vermont Castings, Majestic Products DVRT36/39/4310002428 Fig. 62 Bay windowFor Use in Mobile Homes Model DVRT36RMH Conversion InstructionsVermont Castings, Majestic Products DVRT36/39/43 10002428Vermont Castings, Majestic Products DVRT36/39/43 9b.Units with Honeywell valve10002428 LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTYIF WARRANTY SERVICE IS NEEDED… Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products DVRT36/39/43 10002428Efficiency Ratings Vermont Castings, Majestic ProductsModel EnerGuide Ratings