Vermont Casting For Use in Mobile Homes Model DVRT36RMH, Conversion Instructions, 10002428

Page 46
For Use in Mobile Homes: Model DVRT36RMH

Vermont Castings, Majestic Products DVRT36/39/43

For Use in Mobile Homes: Model DVRT36RMH

This appliance may be installed as an OEM installation in a manufactured home (US only), or a mobile home; it must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard Title 24 CFR Part 3280, or Standard for Installation in Mobile Homes CAN/ CSA Z240 MH.

This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the appliance.

This gas fireplace should be installed by a qualified installer in accordance with local building codes, and with current CSA-B149.1 Installation codes for Gas Burning Fireplaces and Equipment, and CAN/ CSA Z 240.4 Canada.

A manufactured home (US only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR Part 3280, or when such a standard is not applicable, the Standard for Manufactured Home Installations ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing

CSA Z240.4.

The appliance when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current National Electrical Code, ANSI/ NFPA 70, or the Canadian Electrical Code, CSA C22.1.

FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING:

1.This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adults should be alerted to the hazards of fireplace high surface temperatures and should stay away to avoid burns or ignition of clothing.

3.Children should be carefully supervised when in the same room as your fireplace.

4.Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again.

5.Installation and any repairs to fireplace should be performed by qualified installer, service agency or gas supplier. A professional service person should be contacted to inspect fireplace annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

6.Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this fireplace.

7.The venting system (chimney) of this fireplace

should be checked at least once a year and if needed your venting system should be cleaned.

8.Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for clothing, nor should Christmas stockings or decorations be hung on or around the fireplace.

9.Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace.

10.The flow of combustion and ventilation air must not be obstructed in any way.

11.When the fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, the fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace.

12.This fireplace requires adequate ventilation and combustion air to operate properly.

Vermont Castings, Majestic Products Model DVRT36RMH must be firmly attached to the building.

Conversion Instructions

1.Discount power to unit and shut off the gas supply.

2.Remove the window frame assembly (see ‘Window Frame Assembly’ section).

3.Carefully remove the logs.

4.Remove the pilot assembly from bracket.

5.Remove the screws which are holding the burner housing assembly in place.

6.Remove the burner housing assembly.

7.Remove the main and front orifice and replace with the orifice supplied in the conversion kit. Use the small orifice size for the front burner and the bigger orifice size for the main burner.

46

10002428

Image 46
Contents Vermont Castings, Majestic Products Homeowners InstallationDirect Vent Models DVRT36 DVRT39 DVRT43 INSTALLER/CONSUMER SAFETY INFORMATIONInstallation & Operating Instructions Table of ContentsVermont Castings, Majestic Products DVRT36/39/43 Venting Installation InstructionsVermont Castings, Majestic Products DVRT36/39/43 Installation & Operating InstructionsLocating the Fireplace 10002428Vermont Castings, Majestic Products DVRT36/39/43 Fireplace Dimensions Installed as Top VentFraming Dimensions DVRT36Vermont Castings, Majestic Products DVRT36/39/43 Fireplace Dimensions Installed as Rear Vent10002428 Hearth Clearance to CombustiblesMantels Vermont Castings, Majestic Products DVRT36/39/43Final Finishing Gas SpecificationsFraming & Finishing Gas Inlet and Manifold PressuresAlternate Switch Location Gas Line InstallationRemote ON/ OFF Switch Installation Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products DVRT36/39/43 EB-1Electrical BoxElectronic Gas Control Valve 10002428Vermont Castings, Majestic Products DVRT36/39/43 Installing the DVRT36RMH in a Mobile HomeOptional Top Vent Application 10002428Vermont Castings, Majestic Products DVRT36/39/43 General Venting10002428 Vermont Castings, Majestic Products DVRT36/39/43 Canadian Installations1US Installations2 10002428Vermont Castings, Majestic Products DVRT36/39/43 General Information for Connecting Vent PipesCrimped End Pipes 10002428Rear Wall Vent Application How to Use the Vent GraphTwist-lockPipes Vermont Castings, Majestic Products DVRT36/39/43Step Rear Wall Vent InstallationVermont Castings, Majestic Products DVRT36/39/43 StepVermont Castings, Majestic Products DVRT36/39/43 Vertical Sidewall Application10002428 Vermont Castings, Majestic Products DVRT36/39/43 Vertical Sidewall Installation10002428 Vermont Castings, Majestic Products DVRT36/39/43 Below Grade Installation10002428 Do not backfill around snorkel Vertical Through-the-RoofApplicationVermont Castings, Majestic Products DVRT36/39/43 10002428Vermont Castings, Majestic Products DVRT36/39/43 Vertical Through-the-RoofInstallation10002428 Clearance to Combustibles Gravity Ducting SystemVermont Castings, Majestic Products DVRT36/39/43 Min 2’ 610 mmGravity Vermont Castings, Majestic Products DVRT36/39/43Sheet Metal ScrewsVermont Castings, Majestic Products DVRT36/39/43 Twist Lock Venting Components10002428 Vermont Castings, Majestic Products DVRT36/39/43 Crimped End Venting Components10002428 Operating Instructions Window Frame Assembly RemovalGlass Cleaning Glass InformationVermont Castings, Majestic Products DVRT36/39/43 Installation of Logs & Lava Rock10002428 Vermont Castings, Majestic Products DVRT36/39/43 Flame & Temperature AdjustmentFlame Characteristics 10002428Vermont Castings, Majestic Products DVRT36/39/43 Inspecting the Venting System10002428 Lighting Instructions FOR YOUR SAFETY, READ BEFORE LIGHTINGLighting & Operating Instructions To Turn Off Gas to HeaterTurning Off the Gas to the Appliance For Your Safety, Read the Following Warningsbefore Lighting the Appliance Vermont Castings, Majestic Products DVRT36/39/43Operation of RF Comfort Control Valve Shutoff ProcedureInstructions for RF Comfort Control Valve Transmitter OperationDelay Time Mode Disable Thermostat FunctionTroubleshooting RF Comfort Control Valve Auto ModeAuto Path Auto Path ChartVermont Castings, Majestic Products DVRT36/39/43 10002428LOCAL to RE Vermont Castings, Majestic Products DVRT36/39/4310002428 LOCALVermont Castings, Majestic Products DVRT36/39/43 Troubleshooting - Honeywell VS842110002428 Vermont Castings, Majestic Products DVRT36/39/43 Troubleshooting the Gas Control SystemSYMPTOM SIT NOVA 820 MILLIVOLT VALVESIT 822 Valve with a Honeywell Electronic Igniter Troubleshooting the Gas Control SystemVermont Castings, Majestic Products DVRT36/39/43 STARTVermont Castings, Majestic Products DVRT36/39/43 Fuel Conversion Instructions10002428 Vermont Castings, Majestic Products DVRT36/39/43 MaintenanceCleaning the Standing Pilot Control System 1000242810002428 DVRT36/39/43Vermont Castings, Majestic Products DVRT36/39/43 DVRT43DVRT36 Vermont Castings, Majestic Products DVRT36/39/43Description DVRT39Vermont Castings, Majestic Products DVRT36/39/43 DVRT36/39/43 continued10002428 Fan Kits Optional AccessoriesHard Direct Wire Hookup Vermont Castings, Majestic Products DVRT36/39/43Decorative Bay Window Remote ControlsCeramic Refractory Panels Vermont Castings, Majestic Products DVRT36/39/4310002428 Decorative Frame TrimVermont Castings, Majestic Products DVRT36/39/43 Fig. 62 Bay windowVermont Castings, Majestic Products DVRT36/39/43 For Use in Mobile Homes Model DVRT36RMHConversion Instructions 100024289b.Units with Honeywell valve Vermont Castings, Majestic Products DVRT36/39/4310002428 IF WARRANTY SERVICE IS NEEDED… LIMITED LIFETIME WARRANTYPRODUCT COVERED BY THIS WARRANTY Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products DVRT36/39/43 10002428Model Efficiency RatingsVermont Castings, Majestic Products EnerGuide Ratings