Operating Instructions

Vermont Castings, Majestic Products DVRT36/39/43

Operating Instructions

Glass Information

Only glass approved by Vermont Castings, Majestic Products should be used on this fireplace.

The use of any nonapproved replacement glass will void all product warranties.

Care must be taken to avoid breakage of the glass.

Do not operate appliance with glass front removed, cracked or broken.

Replacement glass (complete with gasket) is available through your Vermont Castings, Majestic Products dealer and should be installed only by a licensed qualified service person.

Louvre Removal

Remove the louvre assembly top by lifting the panel up and out from the fireplace. (Fig. 41)

The louvre assembly bottom is hinged at the bottom edge and swings down.

2.

 

Louvre

1.

Assembly Top

 

 

Window Frame Assembly

 

FP444

Fig. 41 Remove louvre assembly top.

Window Frame Assembly Removal

1.Turn the fireplace OFF (including the pilot).

2.If the unit has been operating, allow time for the components to cool.

3.Remove the louvre assembly top.

4.Open the louvre assembly bottom.

5.Release the two (2) clamps along lower edge of the frame by pulling down on clamp handles. (Fig. 42)

6.Tilt window frame assembly out slightly at the bottom, lift the frame up and away from the fireplace.

7.To replace window frame assembly, reverse this procedure.

Lower

Clamps

 

Window

 

Frame

Window

Assembly

 

Frame

 

Assembly

Pull Clamp

Push

Hook

Clamp

 

Handle

 

 

FP1191

Fig. 42 Window frame assembly removal.

Glass Cleaning

It is necessary to periodically clean the glass panel. It is normal for condensation to form on the inside of the glass during start-up. This condensation causes lint, dust, and other airborne particles to cling to glass surface. Also, initial paint curing may deposit a slight film on the glass.

Cleaning the glass two or three times within the first few weeks of operation is recommended, using non- ammonia based household cleaner and warm water, or gas fireplace glass cleaner.

After the initial cleaning process, the glass should be cleaned two or three times during each operating season, depending on the environment in the house.

Clean the glass after the first two weeks of operation.

Do not clean glass when it is hot.

Do not use abrasive cleaners.

Do not strike or slam the glass.

10002428

25

Image 25
Contents Direct Vent Models DVRT36 DVRT39 DVRT43 Homeowners InstallationVermont Castings, Majestic Products INSTALLER/CONSUMER SAFETY INFORMATIONVermont Castings, Majestic Products DVRT36/39/43 Table of ContentsInstallation & Operating Instructions Venting Installation InstructionsLocating the Fireplace Installation & Operating InstructionsVermont Castings, Majestic Products DVRT36/39/43 10002428Framing Dimensions Fireplace Dimensions Installed as Top VentVermont Castings, Majestic Products DVRT36/39/43 DVRT36Vermont Castings, Majestic Products DVRT36/39/43 Fireplace Dimensions Installed as Rear Vent10002428 Mantels Clearance to CombustiblesHearth Vermont Castings, Majestic Products DVRT36/39/43Framing & Finishing Gas SpecificationsFinal Finishing Gas Inlet and Manifold PressuresRemote ON/ OFF Switch Installation Gas Line InstallationAlternate Switch Location Vermont Castings, Majestic Products DVRT36/39/43Electronic Gas Control Valve EB-1Electrical BoxVermont Castings, Majestic Products DVRT36/39/43 10002428Optional Top Vent Application Installing the DVRT36RMH in a Mobile HomeVermont Castings, Majestic Products DVRT36/39/43 10002428Vermont Castings, Majestic Products DVRT36/39/43 General Venting10002428 US Installations2 Canadian Installations1Vermont Castings, Majestic Products DVRT36/39/43 10002428Crimped End Pipes General Information for Connecting Vent PipesVermont Castings, Majestic Products DVRT36/39/43 10002428Twist-lockPipes How to Use the Vent GraphRear Wall Vent Application Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products DVRT36/39/43 Rear Wall Vent InstallationStep StepVermont Castings, Majestic Products DVRT36/39/43 Vertical Sidewall Application10002428 Vermont Castings, Majestic Products DVRT36/39/43 Vertical Sidewall Installation10002428 Vermont Castings, Majestic Products DVRT36/39/43 Below Grade Installation10002428 Vermont Castings, Majestic Products DVRT36/39/43 Vertical Through-the-RoofApplicationDo not backfill around snorkel 10002428Vermont Castings, Majestic Products DVRT36/39/43 Vertical Through-the-RoofInstallation10002428 Vermont Castings, Majestic Products DVRT36/39/43 Gravity Ducting SystemClearance to Combustibles Min 2’ 610 mmSheet Metal Vermont Castings, Majestic Products DVRT36/39/43Gravity ScrewsVermont Castings, Majestic Products DVRT36/39/43 Twist Lock Venting Components10002428 Vermont Castings, Majestic Products DVRT36/39/43 Crimped End Venting Components10002428 Glass Cleaning Window Frame Assembly RemovalOperating Instructions Glass InformationVermont Castings, Majestic Products DVRT36/39/43 Installation of Logs & Lava Rock10002428 Flame Characteristics Flame & Temperature AdjustmentVermont Castings, Majestic Products DVRT36/39/43 10002428Vermont Castings, Majestic Products DVRT36/39/43 Inspecting the Venting System10002428 Lighting & Operating Instructions FOR YOUR SAFETY, READ BEFORE LIGHTINGLighting Instructions To Turn Off Gas to Heaterbefore Lighting the Appliance For Your Safety, Read the Following WarningsTurning Off the Gas to the Appliance Vermont Castings, Majestic Products DVRT36/39/43Instructions for RF Comfort Control Valve Shutoff ProcedureOperation of RF Comfort Control Valve Transmitter OperationTroubleshooting RF Comfort Control Valve Disable Thermostat FunctionDelay Time Mode Auto ModeVermont Castings, Majestic Products DVRT36/39/43 Auto Path ChartAuto Path 1000242810002428 Vermont Castings, Majestic Products DVRT36/39/43LOCAL to RE LOCALVermont Castings, Majestic Products DVRT36/39/43 Troubleshooting - Honeywell VS842110002428 SYMPTOM Troubleshooting the Gas Control SystemVermont Castings, Majestic Products DVRT36/39/43 SIT NOVA 820 MILLIVOLT VALVEVermont Castings, Majestic Products DVRT36/39/43 Troubleshooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Igniter STARTVermont Castings, Majestic Products DVRT36/39/43 Fuel Conversion Instructions10002428 Cleaning the Standing Pilot Control System MaintenanceVermont Castings, Majestic Products DVRT36/39/43 10002428Vermont Castings, Majestic Products DVRT36/39/43 DVRT36/39/4310002428 DVRT43Description Vermont Castings, Majestic Products DVRT36/39/43DVRT36 DVRT39Vermont Castings, Majestic Products DVRT36/39/43 DVRT36/39/43 continued10002428 Hard Direct Wire Hookup Optional AccessoriesFan Kits Vermont Castings, Majestic Products DVRT36/39/43Ceramic Refractory Panels Remote ControlsDecorative Bay Window Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products DVRT36/39/43 Decorative Frame Trim10002428 Fig. 62 Bay windowConversion Instructions For Use in Mobile Homes Model DVRT36RMHVermont Castings, Majestic Products DVRT36/39/43 100024289b.Units with Honeywell valve Vermont Castings, Majestic Products DVRT36/39/4310002428 PRODUCT COVERED BY THIS WARRANTY LIMITED LIFETIME WARRANTYIF WARRANTY SERVICE IS NEEDED… Vermont Castings, Majestic Products DVRT36/39/4310002428 Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products Efficiency RatingsModel EnerGuide Ratings