Vermont Casting DVRT43 manual Troubleshooting the Gas Control System, SIT NOVA 820 MILLIVOLT VALVE

Page 36
Troubleshooting the Gas Control System

Vermont Castings, Majestic Products DVRT36/39/43

Troubleshooting the Gas Control System

SIT NOVA 820 MILLIVOLT VALVE

Note: Before trouble shooting the gas control system, be sure external gas shut off is in the “ON” position.

WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT.

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

 

 

 

 

1. Spark ignitor will not light.

A. Defective or misaligned

Using a match, light pilot. If pilot lights, turn off

 

 

electrode at pilot

pilot and push the red button again. If pilot will not

 

 

 

light, check gap at electrode and pilot; it should be

 

 

 

1/8 in. to have a strong spark.

 

 

 

 

 

 

B. Defective ignitor

Push Piezo Ignitor Button. Check for spark at

 

 

(Push Button)

electrode and pilot. If no spark to pilot, and elec-

 

 

 

trode wire is properly connected, replace ignitor.

 

 

 

 

2. Pilot will not stay lit after

A. Defective pilot generator

Check pilot flame. Must impinge on thermocouple/

carefully following lighting

(thermocouple); remote

thermopile. NOTE: This pilot burner assembly

instructions.

wall switch

utilizes both—a thermocouple and a thermopile.

 

 

 

The thermocouple operates the main valve

 

 

 

operation (On and Off). Clean and/or adjust pilot

 

 

 

for maximum flame impingement on thermopile

 

 

 

and thermocouple.

 

 

 

 

 

 

B. Defective automatic valve

Turn valve knob to “Pilot.” Maintain flow to pilot;

 

 

 

millivolt meter should read greater than 10 mV. If

 

 

 

the reading is okay and the pilot does not stay On,

 

 

 

replace the gas valve. NOTE: An interrupter block

 

 

 

(not supplied) must be used to conduct this test.

 

 

 

 

3. Pilot burning; no gas to

A. Wall switch or wires defective

Check wall switch and wires for proper connec-

main burner

 

tions. Jumper wire across terminals at wall

 

 

 

switch; if burner comes on, replace defective wall

 

 

 

switch. If okay, jumper wires across wall switch

 

 

 

wires at valve. If burner comes on, wires are faulty

 

 

 

or connections are bad.

 

 

 

 

 

 

B. Thermopile may not be

1. Be sure wire connections from thermopile at

 

 

generating sufficient

gas valve terminals are tight and thermopile is

 

 

millivoltage

fully inserted into pilot bracket.

 

 

 

2. One of the wall switch wires may be grounded.

 

 

 

Remove wall switch wires from valve terminals;

 

 

 

if pilot now stays lit, trace wall switch wiring for

 

 

 

ground. May be grounded to fireplace or gas

 

 

 

supply.

 

 

 

3. Check thermopile with millivolt meter. Take

 

 

 

reading at thermopile terminals of gas valve.

 

 

 

Should read 250–300 millivolts (minimum 150)

 

 

 

while holding valve knob depressed in pilot

 

 

 

position and wall switch “Off.” Replace faulty

 

 

 

thermopile if reading is below specified minimum.

 

 

 

 

 

 

C. Plugged burner orifice

Check burner orifices for debris and remove.

 

 

 

 

 

 

D. Defective automatic valve

Turn valve knob to “On;” place wall switch to “On.”

 

 

operator

Millivolt meter should read greater than 100 mV. If

 

 

 

the reading is okay and the burner does not come

 

 

 

On, replace the gas valve.

 

 

 

 

4. Frequent pilot outage

A. Pilot flame may be too low

Clean and/or adjust pilot flame for maximum flame

problem

or blowing (high), causing the

impingement on thermopile and thermocouple.

 

 

pilot safety to drop out.

 

 

 

 

 

 

 

B. Possible blockage of the vent

Check the vent terminal for blockage (recycling the

 

 

terminal

flue gases).

 

 

 

 

36

10002428

Image 36
Contents Homeowners Installation Direct Vent Models DVRT36 DVRT39 DVRT43Vermont Castings, Majestic Products INSTALLER/CONSUMER SAFETY INFORMATIONTable of Contents Vermont Castings, Majestic Products DVRT36/39/43Installation & Operating Instructions Venting Installation InstructionsInstallation & Operating Instructions Locating the FireplaceVermont Castings, Majestic Products DVRT36/39/43 10002428Fireplace Dimensions Installed as Top Vent Framing DimensionsVermont Castings, Majestic Products DVRT36/39/43 DVRT36Fireplace Dimensions Installed as Rear Vent Vermont Castings, Majestic Products DVRT36/39/4310002428 Clearance to Combustibles MantelsHearth Vermont Castings, Majestic Products DVRT36/39/43Gas Specifications Framing & FinishingFinal Finishing Gas Inlet and Manifold PressuresGas Line Installation Remote ON/ OFF Switch InstallationAlternate Switch Location Vermont Castings, Majestic Products DVRT36/39/43EB-1Electrical Box Electronic Gas Control ValveVermont Castings, Majestic Products DVRT36/39/43 10002428Installing the DVRT36RMH in a Mobile Home Optional Top Vent ApplicationVermont Castings, Majestic Products DVRT36/39/43 10002428General Venting Vermont Castings, Majestic Products DVRT36/39/4310002428 Canadian Installations1 US Installations2Vermont Castings, Majestic Products DVRT36/39/43 10002428General Information for Connecting Vent Pipes Crimped End PipesVermont Castings, Majestic Products DVRT36/39/43 10002428How to Use the Vent Graph Twist-lockPipesRear Wall Vent Application Vermont Castings, Majestic Products DVRT36/39/43Rear Wall Vent Installation Vermont Castings, Majestic Products DVRT36/39/43Step StepVertical Sidewall Application Vermont Castings, Majestic Products DVRT36/39/4310002428 Vertical Sidewall Installation Vermont Castings, Majestic Products DVRT36/39/4310002428 Below Grade Installation Vermont Castings, Majestic Products DVRT36/39/4310002428 Vertical Through-the-RoofApplication Vermont Castings, Majestic Products DVRT36/39/43Do not backfill around snorkel 10002428Vertical Through-the-RoofInstallation Vermont Castings, Majestic Products DVRT36/39/4310002428 Gravity Ducting System Vermont Castings, Majestic Products DVRT36/39/43Clearance to Combustibles Min 2’ 610 mmVermont Castings, Majestic Products DVRT36/39/43 Sheet MetalGravity ScrewsTwist Lock Venting Components Vermont Castings, Majestic Products DVRT36/39/4310002428 Crimped End Venting Components Vermont Castings, Majestic Products DVRT36/39/4310002428 Window Frame Assembly Removal Glass CleaningOperating Instructions Glass InformationInstallation of Logs & Lava Rock Vermont Castings, Majestic Products DVRT36/39/4310002428 Flame & Temperature Adjustment Flame CharacteristicsVermont Castings, Majestic Products DVRT36/39/43 10002428Inspecting the Venting System Vermont Castings, Majestic Products DVRT36/39/4310002428 FOR YOUR SAFETY, READ BEFORE LIGHTING Lighting & Operating InstructionsLighting Instructions To Turn Off Gas to HeaterFor Your Safety, Read the Following Warnings before Lighting the ApplianceTurning Off the Gas to the Appliance Vermont Castings, Majestic Products DVRT36/39/43Shutoff Procedure Instructions for RF Comfort Control ValveOperation of RF Comfort Control Valve Transmitter OperationDisable Thermostat Function Troubleshooting RF Comfort Control ValveDelay Time Mode Auto ModeAuto Path Chart Vermont Castings, Majestic Products DVRT36/39/43Auto Path 10002428Vermont Castings, Majestic Products DVRT36/39/43 10002428LOCAL to RE LOCALTroubleshooting - Honeywell VS8421 Vermont Castings, Majestic Products DVRT36/39/4310002428 Troubleshooting the Gas Control System SYMPTOMVermont Castings, Majestic Products DVRT36/39/43 SIT NOVA 820 MILLIVOLT VALVETroubleshooting the Gas Control System Vermont Castings, Majestic Products DVRT36/39/43SIT 822 Valve with a Honeywell Electronic Igniter STARTFuel Conversion Instructions Vermont Castings, Majestic Products DVRT36/39/4310002428 Maintenance Cleaning the Standing Pilot Control SystemVermont Castings, Majestic Products DVRT36/39/43 10002428DVRT36/39/43 Vermont Castings, Majestic Products DVRT36/39/4310002428 DVRT43Vermont Castings, Majestic Products DVRT36/39/43 DescriptionDVRT36 DVRT39DVRT36/39/43 continued Vermont Castings, Majestic Products DVRT36/39/4310002428 Optional Accessories Hard Direct Wire HookupFan Kits Vermont Castings, Majestic Products DVRT36/39/43Remote Controls Ceramic Refractory PanelsDecorative Bay Window Vermont Castings, Majestic Products DVRT36/39/43Decorative Frame Trim Vermont Castings, Majestic Products DVRT36/39/4310002428 Fig. 62 Bay windowFor Use in Mobile Homes Model DVRT36RMH Conversion InstructionsVermont Castings, Majestic Products DVRT36/39/43 10002428Vermont Castings, Majestic Products DVRT36/39/43 9b.Units with Honeywell valve10002428 LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTYIF WARRANTY SERVICE IS NEEDED… Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products DVRT36/39/43 10002428Efficiency Ratings Vermont Castings, Majestic ProductsModel EnerGuide Ratings