Vermont Castings, Majestic Products DVRT36/39/43
Framing & Finishing
Check the fireplace to make sure it is leveled and properly positioned.
1.Choose the unit location.
2.Place the unit into position and secure it to the floor with 1¹⁄₂” (38mm) screws or nails. Holes for securing the unit to floor are located behind the access door grille on the left and right sides of the unit.
3.Frame in the fireplace with a header across the top. It is important to allow for the finished wall face when setting the depth of the frame.
4.Attach the fireplace to the frame using the adjustable frame drywall strips (located behind the access door for shipping). Preset the depth to suit the facing material of the wall. The strips are adjustable to 1/2” (13mm), 5/8” (16mm) or
3/4” (19mm). (Fig. 5)
5.Screw through the slotted holes in the drywall strip and into predrilled holes in fireplace side. Measure from face of fireplace to the face of the drywall strip to confirm the final depth.
| C | Adjustable Drywall Strip | |
| A | ||
| (Nailing Flange) | ||
|
| ||
| B |
|
|
|
| Screw | Drywall |
|
| Position | Depths |
|
| A | 1/2” (13mm) |
|
| B | 5/8” (16mm) |
|
| C | 3/4” (19mm) |
|
| Adjustable |
|
|
| 1/2” – 5/8” – 3/4” | |
|
| Spacing |
|
|
|
| FP1023 |
Fig. 5 | Adjustable drywall strip (nailing flanges). |
Final Finishing
Noncombustible materials such as brick or tile may be extended over the edges of the face of the appliance.
DO NOT cover the window frame assembly, any vent, louvre assembly top or louvre assembly bottom.
If a Trim Kit is to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the appliance.
Gas Specifications
|
|
| Max. | Min. |
|
|
| Input | Input |
Model | Fuel | Gas Control | BTU/h | BTU/h |
DVRT36RN | Nat | Millivolt | 25,000 | 17,500 |
DVRT36RP | Prop | Millivolt | 25,000 | 18,750 |
DVRT36EN | Nat | 24V Hi/Lo | 25,000 | 17,500 |
DVRT36EP | Prop | 24V Hi/Lo | 25,000 | 18,750 |
DVRT36RFN | Nat | Comfort Control | 25,000 | 17,500 |
DVRT36RFP | Prop | Comfort Control | 25,000 | 18,750 |
DVRT36RMH | Nat/ Prop | Millivolt | 25,000 | 17,500 |
DVRT39RN | Nat | Millivolt | 30,000 | 21,000 |
DVRT39RP | Prop | Millivolt | 30,000 | 22,500 |
DVRT39EN | Nat | 24V Hi/Lo | 30,000 | 21,000 |
DVRT39EP | Prop | 24V Hi/Lo | 30,000 | 22,500 |
DVRT43RN | Nat | Millivolt | 33,000 | 23,100 |
DVRT43RP | Prop | Millivolt | 33,000 | 24,750 |
DVRT43EN | Nat | 24V Hi/Lo | 33,000 | 23,100 |
DVRT43EP | Prop | 24V Hi/Lo | 33,000 | 24,750 |
Gas Inlet and Manifold Pressures
| Natural | LP (Propane) |
Inlet Minimum | 5.5” w.c. | 11.0” w.c. |
Inlet Maximum | 14.0” w.c. | 14.0” w.c. |
Manifold Pressure | 3.5” w.c. | 10.0” w.c. |
|
|
|
DVRT36/ DVRT36RMH/ DVRT39/ DVRT43
Certified To
ANSI
Vented Gas Fireplace Heaters
High Elevations
Input ratings are shown in BTU per hour (BTU/h) and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370 m).
10002428 | 7 |