Vermont Casting DVRT39 For Your Safety, Read Before Lighting, Lighting & Operating Instructions

Page 29
Lighting & Operating Instructions

Vermont Castings, Majestic Products DVRT36/39/43

Lighting & Operating Instructions

FOR YOUR SAFETY, READ BEFORE LIGHTING.

WARNING: If you do not follow these instructions exactly, a fire or explosion

may result, causing property damage, personal injury or loss of life.

A.This heater has a pilot light, which must be lit manually. When lighting the pilot follow these instructions exactly:

B.BEFORE LIGHTING, smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace.

Do not touch any electric switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise FOR YOUR SAFETY, READ BEFORE LIGHTING. to "OFF".

 

 

 

 

PILOT

T

OFF

 

 

 

 

 

 

 

1

 

 

PILO

 

t

 

F

 

 

 

 

 

 

 

 

o

 

 

ON

ON

 

P

 

 

 

F

 

 

F

 

l

 

 

 

 

 

 

i

 

2

 

 

 

 

O

 

O

 

 

 

F

 

 

 

 

 

 

5

 

3

 

FFO

 

 

4

 

 

 

 

 

 

 

 

 

 

Euro SIT

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counter-clockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress- ing the Piezo spark igniter until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2" Lighting InstructionsTo Turn Off Gas to HeaterManual background

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas to Heater

1.Turn the On/Off switch to Off position or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn

clockwise Manual background to "OFF". Do not force.

5.Close control access panel.

10002428

29

Image 29
Contents Direct Vent Models DVRT36 DVRT39 DVRT43 Homeowners InstallationVermont Castings, Majestic Products INSTALLER/CONSUMER SAFETY INFORMATIONVermont Castings, Majestic Products DVRT36/39/43 Table of ContentsInstallation & Operating Instructions Venting Installation InstructionsLocating the Fireplace Installation & Operating InstructionsVermont Castings, Majestic Products DVRT36/39/43 10002428Framing Dimensions Fireplace Dimensions Installed as Top VentVermont Castings, Majestic Products DVRT36/39/43 DVRT3610002428 Fireplace Dimensions Installed as Rear VentVermont Castings, Majestic Products DVRT36/39/43 Mantels Clearance to CombustiblesHearth Vermont Castings, Majestic Products DVRT36/39/43Framing & Finishing Gas SpecificationsFinal Finishing Gas Inlet and Manifold PressuresRemote ON/ OFF Switch Installation Gas Line InstallationAlternate Switch Location Vermont Castings, Majestic Products DVRT36/39/43Electronic Gas Control Valve EB-1Electrical BoxVermont Castings, Majestic Products DVRT36/39/43 10002428Optional Top Vent Application Installing the DVRT36RMH in a Mobile HomeVermont Castings, Majestic Products DVRT36/39/43 1000242810002428 General VentingVermont Castings, Majestic Products DVRT36/39/43 US Installations2 Canadian Installations1Vermont Castings, Majestic Products DVRT36/39/43 10002428Crimped End Pipes General Information for Connecting Vent PipesVermont Castings, Majestic Products DVRT36/39/43 10002428Twist-lockPipes How to Use the Vent GraphRear Wall Vent Application Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products DVRT36/39/43 Rear Wall Vent InstallationStep Step10002428 Vertical Sidewall ApplicationVermont Castings, Majestic Products DVRT36/39/43 10002428 Vertical Sidewall InstallationVermont Castings, Majestic Products DVRT36/39/43 10002428 Below Grade InstallationVermont Castings, Majestic Products DVRT36/39/43 Vermont Castings, Majestic Products DVRT36/39/43 Vertical Through-the-RoofApplicationDo not backfill around snorkel 1000242810002428 Vertical Through-the-RoofInstallationVermont Castings, Majestic Products DVRT36/39/43 Vermont Castings, Majestic Products DVRT36/39/43 Gravity Ducting SystemClearance to Combustibles Min 2’ 610 mmSheet Metal Vermont Castings, Majestic Products DVRT36/39/43Gravity Screws10002428 Twist Lock Venting ComponentsVermont Castings, Majestic Products DVRT36/39/43 10002428 Crimped End Venting ComponentsVermont Castings, Majestic Products DVRT36/39/43 Glass Cleaning Window Frame Assembly RemovalOperating Instructions Glass Information10002428 Installation of Logs & Lava RockVermont Castings, Majestic Products DVRT36/39/43 Flame Characteristics Flame & Temperature AdjustmentVermont Castings, Majestic Products DVRT36/39/43 1000242810002428 Inspecting the Venting SystemVermont Castings, Majestic Products DVRT36/39/43 Lighting & Operating Instructions FOR YOUR SAFETY, READ BEFORE LIGHTINGLighting Instructions To Turn Off Gas to Heaterbefore Lighting the Appliance For Your Safety, Read the Following WarningsTurning Off the Gas to the Appliance Vermont Castings, Majestic Products DVRT36/39/43Instructions for RF Comfort Control Valve Shutoff ProcedureOperation of RF Comfort Control Valve Transmitter OperationTroubleshooting RF Comfort Control Valve Disable Thermostat FunctionDelay Time Mode Auto ModeVermont Castings, Majestic Products DVRT36/39/43 Auto Path ChartAuto Path 1000242810002428 Vermont Castings, Majestic Products DVRT36/39/43LOCAL to RE LOCAL10002428 Troubleshooting - Honeywell VS8421Vermont Castings, Majestic Products DVRT36/39/43 SYMPTOM Troubleshooting the Gas Control SystemVermont Castings, Majestic Products DVRT36/39/43 SIT NOVA 820 MILLIVOLT VALVEVermont Castings, Majestic Products DVRT36/39/43 Troubleshooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Igniter START10002428 Fuel Conversion InstructionsVermont Castings, Majestic Products DVRT36/39/43 Cleaning the Standing Pilot Control System MaintenanceVermont Castings, Majestic Products DVRT36/39/43 10002428Vermont Castings, Majestic Products DVRT36/39/43 DVRT36/39/4310002428 DVRT43Description Vermont Castings, Majestic Products DVRT36/39/43DVRT36 DVRT3910002428 DVRT36/39/43 continuedVermont Castings, Majestic Products DVRT36/39/43 Hard Direct Wire Hookup Optional AccessoriesFan Kits Vermont Castings, Majestic Products DVRT36/39/43Ceramic Refractory Panels Remote ControlsDecorative Bay Window Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products DVRT36/39/43 Decorative Frame Trim10002428 Fig. 62 Bay windowConversion Instructions For Use in Mobile Homes Model DVRT36RMHVermont Castings, Majestic Products DVRT36/39/43 1000242810002428 Vermont Castings, Majestic Products DVRT36/39/439b.Units with Honeywell valve PRODUCT COVERED BY THIS WARRANTY LIMITED LIFETIME WARRANTYIF WARRANTY SERVICE IS NEEDED… Vermont Castings, Majestic Products DVRT36/39/4310002428 Vermont Castings, Majestic Products DVRT36/39/43Vermont Castings, Majestic Products Efficiency RatingsModel EnerGuide Ratings