Vermont Casting DVHVAC36 manual General Information Assembling Vent Pipes, Twist Lock Pipes

Page 11

DVHVAC36

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner

Outside Corner

Alcove Applications*

 

 

 

F =

 

 

G =

 

Combustible

G

Combustible

 

6"

(152 mm)

 

6" (152 mm)

V

Noncombustible

 

 

2"

(51 mm)

 

Noncombustible

 

V

 

F

 

2" (51 mm)

 

 

Balcony -

Balcony -

with no side wall

with perpendicular side wall

M

M

 

V

V

 

P

M =

Combustible &

Noncombustible

Combustible &

M = 24" (610 mm)

Noncombustible

P = 20” (508 mm)

12" (305 mm)

D

C C

V

E

O

E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls

O = 8’ (2.4 m) Min.

No.

 

 

of Caps

DMin.

CMax.

1

3’ (.9 mm)

2 x DActual

2

6’ (1.8 m)

1 x DActual

3

9’ (2.7 m)

2/3 x DActual

4

12’ (3.7 m)

1/2 x DActual

DMin. = # of Termination caps x 3

CMax. = (2 / # termination caps) x DActual

584-15

*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3’ (914 mm) minimum between termination caps. 2. All mechanical air intakes within 10’ (1 m) of a termination cap must be a minimum of 3’ (914 mm) below the termination cap. 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap.

Fig. 10 Termination clearances.

General Information Assembling Vent Pipes

Canadian Installations:

Venting system must be installed in accordance with the current CSA-B149.1 installation code.

USA Installations:

The venting system must conform with local codes and/ or the current National Fuel Gas code ANSI Z223.1/ NFPA 54.

Only venting components manufactured by CFM Corpo- ration can be used in Direct Vent systems.

Twist Lock Pipes

When using CFM Corporation twist-lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the collars on the fireplace and termination, and the sliding joint of any telescopic vent section used in the system.

10001195

To join the twist lock pipes together, simply align the beads of the male end with the grooves of the female end, then while bringing the pipe together, twist the pipe until the flange on the female end contacts the external flange on the male end. It is recommended that you secure the joints with three (3) sheet metal screws, however this is not mandatory with twist lock pipe. (Fig. 11)

To make it easier to assemble the joints we suggest putting a lubricant (Vaseline or similar) on the male end of the twist lock pipe prior to assembly.

 

Male End

Female End

 

Screw Holes

TWL100

Fig. 11

Twist-lock pipe joints.

 

 

 

11

Image 11
Contents Rear Direct Vent Model DVHVAC36 Table of Contents Please Review the Following Carefully Installation & Operating InstructionsDVHVAC36 Fireplace DimensionsClearance to Combustibles Unit AssemblyLocating Your Gas Fireplace Return Air Plenum Framing and FinishingSupply Air Duct Systems MantelGas Inlet & Manifold Pressures Gas Line InstallationFinal Finishing HearthElectrical Specifications Typical gas supply installationLocation of Vent Termination ElectricalGeneral Venting General Venting Information Termination Location Canadian Installations1 US Installations2Twist Lock Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesSidewall Venting Graph How to Use the Vent GraphCorner Installation Rear Wall InstallationsLocate vent opening on wall Vertical Sidewall Applications+ B = 17 5.2m Max Zero clearance sleeve is only required for combustible walls Vertical Sidewall InstallationsAlways install Horizontal vent Ing on a level Plane Below Grade InstallationVertical Through-the-Roof Applications Vertical Through-the-Roof InstallationTypical Ceil Twist Lock Venting Components Operating Instructions Lava Rock Setting Temperature RiseFlame Adjustment Flame CharacteristicsMortar lines must be aligned Ceramic Refractory InstallationInspecting the Venting System Inspecting the Venting/Heating Exchange SystemWhat to do if YOU Smell GAS Lighting & Operating InstructionsTo Turn Off Gas To Heater SIT Nova 825 Millivolt Valve Troubleshooting the Gas Control SystemCleaning the Standing Pilot Control System MaintenanceDescription DVHVAC36DVHVAC36 Remove all plastic from brass trims Optional AccessoriesDecorative Bay Window Do not remove existing window frame as- semblyDVHVAC36 Page Product Covered by this Warranty Limited Lifetime WarrantyAFUE% Efficiency Ratings