Vermont Casting DVHVAC36 manual Fireplace Dimensions

Page 4

DVHVAC36

Fireplace Dimensions

V

Z

G

W

F

X

I

C

U

H

D

A

L

V

E

T

B

K

 

J

PQ

R

O

N M L

Fig. 2 Fireplace specifications.

Ref.

DVHVAC36

Ref.

DVHVAC36

A

36"

(914 mm)

N

9⁵⁄"

(245 mm)

B

34¹⁄"

(870 mm)

O

6⁷⁄"

(175 mm)

C

21"

(533 mm)

P

2⁹⁄₃₂"

(58 mm)

D

33"

(838 mm)

Q

2"

(51 mm)

E

63⁵¹⁄₆₄"

(1621 mm)

R

3¹³⁄₁₆"

(97 mm)

F

70"

(1780 mm)

S

4"

(102 mm)

G

16⁵⁄₃₂"

(410 mm)

T

1/2"

(13 mm)

H

21⁵⁄₃₂"

(537 mm)

U

18"

(457 mm)

I

38³⁄₁₆"

(970 mm)

V

16⁷⁄₂₁"

(412 mm)

J

28¹⁵⁄₁₆"

(735 mm)

W

83¹⁄"

(2111 mm)

K

33¹⁄"

(851 mm)

X

5³⁄"

(136 mm)

L

18³⁄₁₆"

(462 mm)

Y

58³⁄"

(1493 mm)

M

13²¹⁄₃₂"

(347 mm)

Z

41⁹⁄₁₆"

(1056 mm)

4

10001195

Image 4
Contents Rear Direct Vent Model DVHVAC36 Table of Contents Installation & Operating Instructions Please Review the Following CarefullyFireplace Dimensions DVHVAC36Locating Your Gas Fireplace Unit AssemblyClearance to Combustibles Framing and Finishing Supply Air Duct SystemsMantel Return Air PlenumGas Line Installation Final FinishingHearth Gas Inlet & Manifold PressuresTypical gas supply installation Electrical SpecificationsGeneral Venting ElectricalLocation of Vent Termination Canadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Twist Lock PipesHow to Use the Vent Graph Corner InstallationRear Wall Installations Sidewall Venting GraphVertical Sidewall Applications Locate vent opening on wall+ B = 17 5.2m Max Vertical Sidewall Installations Zero clearance sleeve is only required for combustible wallsBelow Grade Installation Always install Horizontal vent Ing on a level PlaneVertical Through-the-Roof Installation Vertical Through-the-Roof ApplicationsTypical Ceil Twist Lock Venting Components Operating Instructions Setting Temperature Rise Flame AdjustmentFlame Characteristics Lava RockCeramic Refractory Installation Inspecting the Venting SystemInspecting the Venting/Heating Exchange System Mortar lines must be alignedTo Turn Off Gas To Heater Lighting & Operating InstructionsWhat to do if YOU Smell GAS Troubleshooting the Gas Control System SIT Nova 825 Millivolt ValveMaintenance Cleaning the Standing Pilot Control SystemDVHVAC36 DescriptionDVHVAC36 Optional Accessories Decorative Bay WindowDo not remove existing window frame as- sembly Remove all plastic from brass trimsDVHVAC36 Page Limited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings AFUE%